Optimizing Design on Emergency Power Supply of Large Dynamotor Unit

Diesel generator unit as the emergency power of the plant has an important effect that whether the generator unit can stop safely or not in the accident conditions. In order to optimize the design of an emergency power for the large dynamotor unit, the 2*600MW aircooling unit emergency load is taken as an example, four kinds wring schemes of the emergency power are designed and constructed by the ETAP software. The reliability, power flow, short-circuit current and economic data of the four schemes are evaluated. Through the comparison, the optimal, economic, and reasonable scheme of the alternating emergency power and diesel generator unit could be put forward, the Option IV is recommended as satisfying emergency power for the 600MW air-cooling unit. The simulation results of 600MW alternating emergency power can also provide a reference for the 1000MW unit design of emergency power.

[1]  Joon-Eon Yang,et al.  A quantitative analysis of a risk impact due to a starting time extension of the emergency diesel generator in optimized power reactor-1000 , 2007, Reliab. Eng. Syst. Saf..

[2]  Dong Jing-we Diesel generator selection and power room design , 2011 .

[3]  Wang Jian,et al.  Simulation of auxiliary power system operating state for 600 MW air-cooling units , 2008, 2008 China International Conference on Electricity Distribution.

[4]  S. A. Eide,et al.  Detailed Study of Emergency Diesel Generator Performance Using EPIX/RADS Database , 2008 .

[5]  Weibo Li,et al.  Comparison with Three Projects of Auxiliary Power Wiring for 1000MW Unit Based on ETAP , 2009, 2009 Asia-Pacific Power and Energy Engineering Conference.

[6]  D. Sarussi,et al.  Design of emergency power systems for reliable uninterrupted high power applications , 2007, 2007 9th International Conference on Electrical Power Quality and Utilisation.

[7]  K. Raja,et al.  Emergency power supply system of a Nuclear Power Plant-modelling and simulation studies of Diesel generators and load pickup on emergency transfer , 2011, 2011 1st International Conference on Electrical Energy Systems.

[8]  Cui Xun Discussion on Function Modification and Startup Test of Emergency Diesel Generator in Power Plant , 2010 .

[9]  Jian Wang,et al.  Study on Large Asynchronous Motor Starting Check for Auxiliary Power System , 2010, 2010 Asia-Pacific Power and Energy Engineering Conference.

[10]  K. E. Yeager,et al.  Modeling of emergency diesel generators in an 800 megawatt nuclear power plant , 1993 .

[11]  Zou Xuan Discussion on the connection scheme of AC emergency power supply for 300MW unit thermal power plant , 2010 .