Optimization of actuator/sensor position of multi-body system with quick startup and brake

A new method was put forward to optimize the position of actuator/sensor of multi-body system with quick startup and brake. Dynamical equation was established for the system with intelligent structure of piezoelectric actuators. According to the property of the modes varying with time, the performance index function was developed based on the optimal configuration principle of energy maximal dissipation, and the relevant optimal model was obtained. According to its characteristic, a float-encoding genetic algorithm, which is efficient, simple and excellent for solving the global-optimal solution of this problem, was adopted. Taking the plane manipulator as an example, the result of numerical calculation shows that, after the actuator/sensor position being optimized, the vibration amplitude of the multi-body system is reduced by 35% compared with that without optimization.

[1]  K. Lim Method for Optimal Actuator and Sensor Placement for Large Flexible Structures , 1992 .

[2]  M. Wegener,et al.  Visualization and analysis of bow shocks in a superorbital expansion tube , 1996 .

[3]  Guang Meng,et al.  Vibration control of piezoelectric smart structures based on system identification technique: Numerical simulation and experimental study , 2006 .

[4]  An-Chen Lee,et al.  Collocated Sensor/Actuator Positioning and Feedback Design in the Control of Flexible Structure System , 1994 .

[5]  Valder Steffen,et al.  Modal Active Vibration Control of a Rotor Using Piezoelectric Stack Actuators , 2007 .

[6]  Young Kyu Kang,et al.  Optimum placement of piezoelectric sensor/actuator for vibration control of laminated beams , 1996 .

[7]  Singiresu S Rao,et al.  Distributed modeling and actuator location for piezoelectric control systems , 1996 .

[8]  James K. Mills,et al.  Vibration Control of a Planar Parallel Manipulator Using Piezoelectric Actuators , 2005, J. Intell. Robotic Syst..

[9]  Zhao Guoqun,et al.  Active control of structural vibration by piezoelectric stack actuators , 2005 .

[10]  An-Chen Lee,et al.  Effective Active Damping Design for Suppression of Vibration in Flexible Systems via Dislocated Sensor/Actuator Positioning , 1994 .

[11]  D Dep COLLOCATED SENSOR/ACTUATOR OPTIMAL POSITIONING AND FEEDBACK DESIGN BY SIMULATED ANNEALING METHOD , 2000 .

[12]  Richard W. Longman,et al.  Actuator placement from degree of controllability criteria for regular slewing of flexible spacecraft , 1981 .

[13]  Hua-ping Tang,et al.  Optimal design method for force in vibration control of multi-body system with quick startup and brake , 2005 .

[14]  Hua-ping Tang,et al.  Active vibration control of multibody system with quick startup and brake based on active damping , 2006 .

[15]  Saburo Matunaga,et al.  Actuator placement with failure consideration for static shape control of truss structures , 1995 .

[16]  Xu Hailiang,et al.  Design and application of a new kind of rolling coupling , 2005 .