EQUIVALENT CIRCUIT IMPROVEMENT METHOD FOR INDUCTION MOTOR EFFICIENCY

The parameters of the equivalent Г-circuit, which is proposed for this improvement method, may be derived by data from the no-load test and locked-rotor test at reduced frequency, but direct calculations, i.e. simpler than parameters of the conventional T - circuit. And as for the simpler Г-circuit, the operating characteristics (losses, output power, efficiency and power factor) are calculated with no loss of accuracy. The accuracy of the proposed procedure was verified on the basis of results of comparative calculations for motor given in the literature.

[1]  E. Davies,et al.  Electrical machines , 2006, 2006 Eleventh International Middle East Power Systems Conference.

[2]  Paul G. Cummings,et al.  Induction Motor Efficiency Test Methods , 1981, IEEE Transactions on Industry Applications.

[3]  Y. El-Ibiary An accurate low cost method for determining electric motors' efficiency for the purpose of plant energy management , 2002, Record of Conference Papers. Industry Applications Society. Forty-Ninth Annual Conference. 2002 Petroleum and Chemical Industry Technical Conference.

[4]  G. Slemon,et al.  An Analysis of the Harmonic Impedance of a Saturated Induction Machine , 1980, IEEE Transactions on Power Apparatus and Systems.