Planar array 3D electrical capacitive tomography

Electrical capacitance tomography (ECT) is a promising non-invasive imaging technique that is capable of mapping the dielectric permittivity of an object. ECT has great potential to be used as a new non-destructive evaluation (NDE) method. In the majority of NDE applications for ECT there is only limited access to the targeted objects, making conventional circular array ECT impractical. In this paper, a planar array ECT system is developed and proposed for 3D subsurface imaging as a form of limited access tomography. The sensor development, practical implications, capabilities and limitations of the proposed planar array ECT system are discussed. The experimental results are used to evaluate the system performance. A depth of up to 53% of the length of the sensor array can be achieved using experimental data using an array of 4 × 3 electrodes.

[1]  Manuchehr Soleimani,et al.  Pipeline inspection using magnetic induction tomographybased on a narrowband pass filtering method , 2012 .

[2]  Liang-Shih Fan,et al.  Electrical Capacitance Volume Tomography , 2007, IEEE Sensors Journal.

[3]  Wuqiang Yang,et al.  Planar capacitive sensors – designs and applications , 2010 .

[4]  Lihui Peng,et al.  Image reconstruction algorithms for electrical capacitance tomography , 2003 .

[5]  David A. Hutchins,et al.  Single-sided capacitive imaging for NDT , 2006 .

[6]  Wenge Chang,et al.  Automated SAR Reference Image Preparation for Navigation , 2011 .

[7]  Fei Wang,et al.  Electrical Capacitance Volume Tomography: Design and Applications , 2010, Sensors.

[8]  R. Banasiak,et al.  Improving Three-Dimensional Electrical Capacitance Tomography Imaging Using Approximation Error Model Theory , 2012 .

[9]  Manuchehr Soleimani,et al.  Nonlinear image reconstruction for electrical capacitance tomography using experimental data , 2005 .

[10]  S. Mylvaganam,et al.  Electrical Capacitance Tomography—Sensor Models, Design, Simulations, and Experimental Verification , 2006, IEEE Sensors Journal.

[11]  Won-Kwang Park ON THE IMAGING OF THIN DIELECTRIC INCLUSIONS VIA TOPOLOGICAL DERIVATIVE CONCEPT , 2010 .

[12]  Richard A Williams,et al.  Process tomography : principles, techniques and applications , 1995 .

[13]  Raja Syamsul Azmir Raja Abdullah,et al.  3D experimental detection and discrimination of malignant and benign breast tumor using NN-based UWB imaging system , 2011 .

[14]  Shunjun Wei,et al.  SPARSE RECONSTRUCTION FOR SAR IMAGING BASED ON COMPRESSED SENSING , 2010 .

[15]  Robert Banasiak,et al.  Spatial imaging with 3D capacitance measurements , 2007 .

[16]  Wuqiang Yang,et al.  An image-reconstruction algorithm based on Landweber's iteration method for electrical-capacitance tomography , 1999 .

[17]  William R B Lionheart,et al.  GREIT: a unified approach to 2D linear EIT reconstruction of lung images , 2009, Physiological measurement.

[18]  Joachim Schöberl,et al.  NETGEN An advancing front 2D/3D-mesh generator based on abstract rules , 1997 .

[19]  Wuqiang Yang,et al.  Design of a security screening system with a capacitance sensor matrix operating in single-electrode mode , 2011 .

[20]  M. El-Shenawee,et al.  Inverse Scattering of Three-Dimensional PEC Objects Using the Level-Set Method , 2011 .

[21]  Kun-Shan Chen,et al.  SAR Image Simulation with Application to Target Recognition , 2011 .

[22]  M. Soleimani,et al.  FOUR DIMENSIONAL RECONSTRUCTION USING MA- GNETIC INDUCTION TOMOGRAPHY: EXPERIMEN- TAL STUDY , 2012 .

[23]  Xiaokang Yin,et al.  Non-destructive evaluation of composite materials using a capacitive imaging technique , 2012 .

[24]  Manuchehr Soleimani,et al.  THREE-DIMENSIONAL NONLINEAR INVERSION OF ELECTRICAL CAPACITANCE TOMOGRAPHY DATA USING A COMPLETE SENSOR MODEL , 2010 .

[25]  Manuchehr Soleimani,et al.  Two-phase low conductivity flow imaging using magnetic induction tomography , 2012 .

[26]  Manuchehr Soleimani Three-dimensional electrical capacitance tomography imaging , 2006 .