Simple method for computing scattered radiation in breast tomosynthesis.

PURPOSE Virtual clinical trials (VCT) are a powerful imaging tool that can be used to investigate digital breast tomosynthesis (DBT) technology. In this work, a fast and simple method is proposed to estimate the 2D distribution of scattered radiation which is needed when simulating DBT geometries in VCTs. METHODS Monte Carlo simulations are used to pre-calculate scatter-to-primary ratio (SPR) for a range of low-resolution homogeneous phantoms. The resulting values can be used to estimate the 2D-distribution of scattered radiation arising from inhomogeneous anthropomorphic phantoms used in VCTs. The method has been validated by comparing the values of the scatter thus obtained against the results of direct Monte Carlo simulation for three different types of inhomogeneous anthropomorphic phantoms. RESULTS Differences between the proposed scatter field estimation method and the ground truth data for the OPTIMAM phantom had an average modulus and standard deviation of over the projected breast area of 2.4 ± 0.9% (minimum -17.0%, maximum 27.7%). The corresponding values for the University of Pennsylvania and Duke University breast phantoms were 1.8 ± 0.1% (minimum -8.7%, maximum 8.0%) and 5.1 ± 0.1% (minimum -16.2%, maximum 7.4%), respectively. CONCLUSIONS The proposed method, which has been validated using three of the most common breast models, is a useful tool for accurately estimating scattered radiation in VCT schemes used to study current designs of DBT system. This article is protected by copyright. All rights reserved.

[1]  J. S. Laughlin,et al.  Absorbed radiation dose in mammography. , 1979, Radiology.

[2]  D R Dance,et al.  The computation of scatter in mammography by Monte Carlo methods. , 1984, Physics in medicine and biology.

[3]  R. Siddon Fast calculation of the exact radiological path for a three-dimensional CT array. , 1985, Medical physics.

[4]  K L Lam,et al.  Studies of performance of antiscatter grids in digital radiography: effect on signal-to-noise ratio. , 1990, Medical physics.

[5]  G T Barnes,et al.  Contrast and scatter in x-ray imaging. , 1991, Radiographics : a review publication of the Radiological Society of North America, Inc.

[6]  D R Dance,et al.  Calculation of dose and contrast for two mammographic grids. , 1992, Physics in medicine and biology.

[7]  U Neitzel,et al.  Grids or air gaps for scatter reduction in digital radiography: a model calculation. , 1992, Medical physics.

[8]  Ralph Highnam,et al.  Computing the scatter component of mammographic images , 1994, IEEE Trans. Medical Imaging.

[9]  T. R. Fewell,et al.  Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography. , 1997, Medical physics.

[10]  J M Boone,et al.  Scatter/primary in mammography: Monte Carlo validation. , 2000, Medical physics.

[11]  A. Dell'Acqua,et al.  Geant4 - A simulation toolkit , 2003 .

[12]  Michael Sandborg,et al.  Implementation of pathologies in the Monte Carlo model in chest and breast imaging , 2003 .

[13]  Nico Karssemeijer,et al.  The value of scatter removal by a grid in full field digital mammography. , 2003, Medical physics.

[14]  Samuli Siltanen,et al.  X-ray scattering in full-field digital mammography. , 2003, Medical physics.

[15]  S. Incerti,et al.  Geant4 developments and applications , 2006, IEEE Transactions on Nuclear Science.

[16]  Aruna A. Vedula,et al.  A computer simulation study comparing lesion detection accuracy with digital mammography, breast tomosynthesis, and cone-beam CT breast imaging. , 2006, Medical physics.

[17]  C. D'Orsi,et al.  Scatter radiation in digital tomosynthesis of the breast. , 2007, Medical physics.

[18]  John M Boone,et al.  Methodology for generating a 3D computerized breast phantom from empirical data. , 2009, Medical physics.

[19]  John M. Boone,et al.  Evaluation of scatter effects on image quality for breast tomosynthesis , 2009 .

[20]  D M Cunha,et al.  Evaluation of scatter-to-primary ratio, grid performance and normalized average glandular dose in mammography by Monte Carlo simulation including interference and energy broadening effects , 2010, Physics in medicine and biology.

[21]  S. Molloi,et al.  Scatter correction in digital mammography based on image deconvolution , 2010, Physics in medicine and biology.

[22]  Kenneth C. Young,et al.  Monte Carlo Simulation of Scatter Field for Calculation of Contrast of Discs in Synthetic CDMAM Images , 2010, Digital Mammography / IWDM.

[23]  I. Sechopoulos,et al.  A software-based x-ray scatter correction method for breast tomosynthesis. , 2011, Medical physics.

[24]  Andrew D. A. Maidment,et al.  Development and characterization of an anthropomorphic breast software phantom based upon region-growing algorithm. , 2011, Medical physics.

[25]  Kenneth C. Young,et al.  A fast scatter field estimator for digital breast tomosynthesis , 2012, Medical Imaging.

[26]  I. Sechopoulos A review of breast tomosynthesis. Part I. The image acquisition process. , 2013, Medical physics.

[27]  Kyle J Myers,et al.  A virtual trial framework for quantifying the detectability of masses in breast tomosynthesis projection data. , 2013, Medical physics.

[28]  Hilde Bosmans,et al.  Development and validation of a modelling framework for simulating 2D-mammography and breast tomosynthesis images , 2014, Physics in medicine and biology.

[29]  C. D'Orsi,et al.  X-ray scatter correction in breast tomosynthesis with a precomputed scatter map library. , 2014, Medical physics.

[30]  D R Dance,et al.  Estimation of scattered radiation in digital breast tomosynthesis , 2014, Physics in medicine and biology.

[31]  Ehsan Samei,et al.  Monte Carlo reference data sets for imaging research: Executive summary of the report of AAPM Research Committee Task Group 195. , 2015, Medical physics.

[32]  Josh Star-Lack,et al.  Asymmetric scatter kernels for software-based scatter correction of gridless mammography , 2015, Medical Imaging.

[33]  Jong Chul Ye,et al.  Fully iterative scatter corrected digital breast tomosynthesis using GPU-based fast Monte Carlo simulation and composition ratio update. , 2015, Medical physics.

[34]  Hammadi Nait-Charif,et al.  Detailed Analysis of Scatter Contribution from Different Simulated Geometries of X-ray Detectors , 2016, Digital Mammography / IWDM.

[35]  F. H. Green,et al.  Scatter free imaging for the improvement of breast cancer detection in mammography. , 2016, Physics in medicine and biology.

[36]  Oliver Díaz,et al.  Scattered radiation in DBT geometries with flexible breast compression paddles: a Monte Carlo simulation study , 2017, Medical Imaging.

[37]  Hammadi Nait-Charif,et al.  Scatter reduction for grid-less mammography using the convolution-based image post-processing technique , 2017, Medical Imaging.

[38]  Otto Zhou,et al.  Estimating scatter from sparsely measured primary signal , 2017, Journal of medical imaging.

[39]  Kenneth C. Young,et al.  Using non-specialist observers in 4AFC human observer studies , 2017, Medical Imaging.

[40]  Premkumar Elangovan,et al.  Design and validation of realistic breast models for use in multiple alternative forced choice virtual clinical trials , 2017, Physics in medicine and biology.

[41]  Premkumar Elangovan,et al.  Lesion detectability in 2D-mammography and digital breast tomosynthesis using different targets and observers , 2018, Physics in medicine and biology.

[42]  Andrew D. A. Maidment,et al.  OpenVCT: a GPU-accelerated virtual clinical trial pipeline for mammography and digital breast tomosynthesis , 2018, Medical Imaging.

[43]  Andrew D. A. Maidment,et al.  Virtual clinical trial of lesion detection in digital mammography and digital breast tomosynthesis , 2018, Medical Imaging.

[44]  M. McNitt-Gray,et al.  RECORDS: improved Reporting of montE CarlO RaDiation transport Studies: Report of the AAPM Research Committee Task Group 268. , 2018, Medical physics.

[45]  Frank W. Samuelson,et al.  Evaluation of Digital Breast Tomosynthesis as Replacement of Full-Field Digital Mammography Using an In Silico Imaging Trial , 2018, JAMA network open.

[46]  David R. Dance,et al.  Can breast models be simplified to estimate scattered radiation in breast tomosythesis? , 2019, Medical Imaging.

[47]  Lesley Cockmartin,et al.  An observer study to assess the detection of calcification clusters using 2D mammography, digital breast tomosynthesis, and synthetic 2D imaging , 2019, Medical Imaging.