Optimisation of the Sputnik-VAD Design

Purpose Miniaturisation of VADs can offer important benefits, including less invasive implantation techniques and more versatility in patient selection. The aim of this work was to reduce the weight, size, and energy consumption of the Sputnik VAD. Methods The second generation of the Sputnik VAD was developed with a set of changes in construction. The head pressure-flow rate (H-Q) and power consumption-flow rate curves for the Sputnik VADs were measured at different rotational speeds. Computational fluid dynamics (CFD) were used for operating condition simulation and the LVADs were compared under the simulated physiological conditions. Results The slope of the H-Q curves for the Sputnik 1 VAD remains almost invariable over the entire range of the measured flow rate, in contrast to the curves for the Sputnik 2 VAD, which become flat in the high flow-rate region. Despite the design modification, the operating rotor speed remained invariable. The preload sensitivity of the Sputnik VAD is higher than that of the other rotary blood pumps and amounts to 0.111 ± 0.0092 L min−1 mmHg−1. The power consumption for the Sputnik 2 VAD is lower over the entire speed range, except for at 5,000 rpm. Conclusions The pump weight was reduced from 246 to 205 g, the pump length was decreased from 82 to 66 mm, and the pump diameter was decreased from 32 to 29 mm. The total energy consumption of the pump was reduced by 15%.

[1]  U. Steinseifer,et al.  Prediction of the external work of the native heart from the dynamic H-Q curves of the rotary blood pumps during left heart bypass. , 2010, Artificial organs.

[2]  R. Adamson,et al.  Opportunities and Challenges for LVAD Therapy Now and in the Future , 2014 .

[3]  Berno J. E. Misgeld,et al.  Robust decentralised control of a hydrodynamic human circulatory system simulator , 2015, Biomed. Signal Process. Control..

[4]  D. Telyshev,et al.  Development of Left Ventricular Assist Devices as the Most Effective Acute Heart Failure Therapy , 2015 .

[5]  A. Untăroiu,et al.  Design and Transient Computational Fluid Dynamics Study of a Continuous Axial Flow Ventricular Assist Device , 2004, ASAIO journal.

[6]  M. Guglin,et al.  Cost of Ventricular Assist Devices: Can We Afford The Progress? , 2013, Circulation.

[7]  D. Telyshev,et al.  Analysis of the Preload and Afterload Sensitivity of the Sputnik Rotary Blood Pump , 2016, BioMed 2016.

[8]  J. Antaki,et al.  Analysis of pressure head-flow loops of pulsatile rotodynamic blood pumps. , 2014, Artificial organs.

[9]  Robert L Kormos,et al.  Sixth INTERMACS annual report: a 10,000-patient database. , 2014, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[10]  R. Jarvik Jarvik 2000 pump technology and miniaturization. , 2014, Heart failure clinics.

[11]  William E. Cohn,et al.  Preload Sensitivity of the Jarvik 2000 and HeartMate II Left Ventricular Assist Devices , 2008, ASAIO journal.

[12]  D. Dowling,et al.  Evaluation of diamond-like carbon-coated orthopaedic implants , 1997 .

[13]  William E Cohn,et al.  Optimization of axial-pump pressure sensitivity for a continuous-flow total artificial heart. , 2010, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[14]  Kiyotaka Fukamachi,et al.  Preload sensitivity in cardiac assist devices. , 2013, The Annals of thoracic surgery.

[15]  C. Bhamidipati,et al.  Orthotopic heart transplant versus left ventricular assist device: a national comparison of cost and survival. , 2013, The Journal of thoracic and cardiovascular surgery.

[16]  D. Mason,et al.  Response of rotary blood pumps to changes in preload and afterload at a fixed speed setting are unphysiological when compared with the natural heart. , 2011, Artificial organs.

[17]  E. G. Konysheva,et al.  Bench Tests of an Implantable Axial Blood Pump , 2011, Meditsinskaia tekhnika.

[18]  S V Selishchev,et al.  Rotor Pumps for Artificial and Assisted Circulation , 2010, Meditsinskaia tekhnika.

[19]  Anson Cheung,et al.  Design Concepts and Preclinical Results of a Miniaturized HeartWare Platform , 2015, Innovations.

[20]  Tomoyuki Yambe,et al.  Sensorless Estimation of Pressure Head and Flow of a Continuous Flow Artificial Heart Based on Input Power and Rotational Speed , 2001, ASAIO journal.

[21]  M C Oz,et al.  Long-term use of a left ventricular assist device for end-stage heart failure. , 2001, The New England journal of medicine.

[22]  S. V. Selishchev,et al.  Bearing Units of an Axial Blood Pump: Design and Triboengineering Features , 2010, Meditsinskaia tekhnika.

[23]  Marcel C M Rutten,et al.  Pump Flow Estimation From Pressure Head and Power Uptake for the HeartAssist5, HeartMate II, and HeartWare VADs , 2013, ASAIO journal.

[24]  Christodoulos Stefanadis,et al.  Vascular wall shear stress: basic principles and methods. , 2005, Hellenic journal of cardiology : HJC = Hellenike kardiologike epitheorese.

[25]  Shmuel Einav,et al.  Thromboresistance comparison of the HeartMate II ventricular assist device with the device thrombogenicity emulation- optimized HeartAssist 5 VAD. , 2014, Journal of biomechanical engineering.

[26]  I. A. Filatov,et al.  Development of Control Unit and Power Source for an Implantable Assisted Circulation Pump , 2010, Meditsinskaia tekhnika.

[27]  Xiwen Zhang,et al.  HYDRODYNAMIC AND HEMOLYSIS ANALYSIS ON DISTANCE AND CLEARANCE BETWEEN IMPELLER AND DIFFUSER OF AXIAL BLOOD PUMP , 2016 .

[28]  Y. Danieli Guide , 2005 .

[29]  Sergey V. Selishchev,et al.  Ventricular Assist Device Sputnik: Description, Technical Features and Characteristics , 2015 .