An improved PSF mapping method for EPI distortion correction in human brain at ultra high field (7T)

ObjectTo further improve the quality and robustness of the point-spread function (PSF) mapping method for fully automatic and accurate correction of geometric distortions in EPI at ultra high field such as 7 Tesla with high fidelity.Materials and methodsConventional gradient-echo EPI and corresponding PSF reference data in phantoms and in in vivo measurements of the human brain were acquired at 7 Tesla. To accurately determine and correct geometric distortions, i.e., in peripheral areas, the method calculates the local shift in the distorted phase-encoding dimension instead of the non-distorted spin-wrap encoding dimension. The results of the proposed method are compared with those originally demonstrated (Zaitsev et al. Magn Reson Med (2004) 52:1156–1166).ResultsThe results show that the proposed method allows measurement and correction of the geometric distortions in EPI with high accuracy, and reduction of residual blurring. In addition, this method prevents errors in the shift map induced by PSF-ghost artifacts.ConclusionMore precise mapping and correction of pixel shifts and blurring is accomplished with the proposed improvements. Errors in the shift map that are caused by PSF-ghost artifacts in the multi-shot PSF acquisition, e.g., from small motion during the reference scan, do not affect the improved shift estimation method.

[1]  Robert Turner,et al.  Image Distortion Correction in fMRI: A Quantitative Evaluation , 2002, NeuroImage.

[2]  M. Zaitsev,et al.  High resolution single-shot EPI at 7T , 2008, Magnetic Resonance Materials in Physics, Biology and Medicine.

[3]  John C Gore,et al.  New approach for correcting distortions in echo planar imaging , 2004, Magnetic resonance in medicine.

[4]  N. Chen,et al.  Optimized distortion correction technique for echo planar imaging , 2001, Magnetic resonance in medicine.

[5]  R. Deichmann,et al.  Optimized EPI for fMRI studies of the orbitofrontal cortex: compensation of susceptibility-induced gradients in the readout direction , 2007, Magnetic Resonance Materials in Physics, Biology and Medicine.

[6]  M Zaitsev,et al.  Point spread function mapping with parallel imaging techniques and high acceleration factors: Fast, robust, and flexible method for echo‐planar imaging distortion correction , 2004, Magnetic resonance in medicine.

[7]  P. Mansfield Multi-planar image formation using NMR spin echoes , 1977 .

[8]  J. Gore,et al.  Measurement of the point spread function in MRI using constant time imaging , 1997, Magnetic resonance in medicine.

[9]  A M Wyrwicz,et al.  Correction for EPI distortions using multi‐echo gradient‐echo imaging , 1999, Magnetic resonance in medicine.

[10]  R Todd Constable,et al.  Image distortion correction in EPI: Comparison of field mapping with point spread function mapping , 2002, Magnetic resonance in medicine.

[11]  D. Parker,et al.  Reduction of geometric and intensity distortions in echo‐planar imaging using a multireference scan , 1997, Magnetic resonance in medicine.

[12]  P. Reber,et al.  Correction of off resonance‐related distortion in echo‐planar imaging using EPI‐based field maps , 1998, Magnetic resonance in medicine.

[13]  C. Ahn,et al.  A New Phase Correction Method in NMR Imaging Based on Autocorrelation and Histogram Analysis , 1987, IEEE Transactions on Medical Imaging.

[14]  I. Johnsrude,et al.  The problem of functional localization in the human brain , 2002, Nature Reviews Neuroscience.

[15]  R Turner,et al.  Optimized EPI for fMRI studies of the orbitofrontal cortex , 2003, NeuroImage.

[16]  K. Amunts,et al.  Towards multimodal atlases of the human brain , 2006, Nature Reviews Neuroscience.

[17]  W. Edelstein,et al.  Spin warp NMR imaging and applications to human whole-body imaging. , 1980, Physics in medicine and biology.

[18]  Ulrich Paquet,et al.  Gaussian process modeling for image distortion correction in echo planar imaging , 2008, Magnetic resonance in medicine.

[19]  J. Ashburner,et al.  Multimodal Image Coregistration and Partitioning—A Unified Framework , 1997, NeuroImage.

[20]  P. Jezzard,et al.  Correction for geometric distortion in echo planar images from B0 field variations , 1995, Magnetic resonance in medicine.