Effect of fluid and food intake on the body composition evaluation of elderly persons

BackgroundSeveral studies have shown that liquid and food intake interfere with the evaluation of body composition in adults. However, since there are no reports about this interference in the elderly population, the need to fast for this evaluation may be dispensable.ObjectivesThe objective of the present study was to assess the influence of liquid and solid food on the measurement of body composition by bioelectrical impedance analysis (BIA) and by dual energy X-ray absorptiometry (DXA).DesignForty-one male volunteers aged 62 to 87 years participated in the study. The subjects were submitted to evaluation of body composition by DXA and BIA under fasting conditions and 1 hour after the ingestion of breakfast (500 ml of orange juice and one 50 g bread roll with butter).ResultsThere was no significant difference in the variables fat-free mass (FFM) or fat mass (FM) between the fasting condition and the evaluation performed 1 hour after the meal as measured by BIA or DXA. There was also no significant difference when the same variables were compared between methods.ConclusionIn the present study, the ingestion of 500 ml orange juice and of one bread roll with butter by elderly subjects did not affect the results of the parameters of body composition determined by BIA or DXA. Thus, these exams could be performed without the rigor of fasting, often poorly tolerated by the elderly.

[1]  W. Chumlea,et al.  Bioelectric impedance methods for the estimation of body composition. , 1990, Canadian journal of sport sciences = Journal canadien des sciences du sport.

[2]  R B Mazess,et al.  Dual-energy x-ray absorptiometry for total-body and regional bone-mineral and soft-tissue composition. , 1990, The American journal of clinical nutrition.

[3]  C. Christiansen,et al.  Measurement of body fat in elderly subjects by dual-energy x-ray absorptiometry, bioelectrical impedance, and anthropometry. , 1991, The American journal of clinical nutrition.

[4]  F. Horber,et al.  Impact of hydration status on body composition as measured by dual energy X-ray absorptiometry in normal volunteers and patients on haemodialysis. , 1992, The British journal of radiology.

[5]  D. Schoeller,et al.  Errors in estimating peritoneal fluid by bioelectrical impedance analysis and total body electrical conductivity. , 1993, Journal of the American College of Nutrition.

[6]  K R Foster,et al.  Whole-body impedance--what does it measure? , 1996, The American journal of clinical nutrition.

[7]  G E Dallal,et al.  Application of bioelectrical impedance analysis to elderly populations. , 1997, The journals of gerontology. Series A, Biological sciences and medical sciences.

[8]  A. Cicognani,et al.  Measurement of body fat in healthy elderly men: a comparison of methods. , 1999, The journals of gerontology. Series A, Biological sciences and medical sciences.

[9]  M. Visser,et al.  Validity of fan-beam dual-energy X-ray absorptiometry for measuring fat-free mass and leg muscle mass. Health, Aging, and Body Composition Study--Dual-Energy X-ray Absorptiometry and Body Composition Working Group. , 1999, Journal of applied physiology.

[10]  J. Cauley,et al.  Measurement of fat mass using DEXA: a validation study in elderly adults. , 2000, Journal of applied physiology.

[11]  J. Moriguti,et al.  Effects of a 6-week hypocaloric diet on changes in body composition, hunger, and subsequent weight regain in healthy young and older adults. , 2000, The journals of gerontology. Series A, Biological sciences and medical sciences.

[12]  M. Bolanowski,et al.  Assessment of human body composition using dual-energy x-ray absorptiometry and bioelectrical impedance analysis. , 2001, Medical science monitor : international medical journal of experimental and clinical research.

[13]  I. Bosaeus,et al.  Comparison of bioelectrical impedance prediction equations for fat-free mass in a population-based sample of 75 y olds: the NORA study. , 2003, Nutrition.

[14]  R. Roubenoff Sarcopenia: effects on body composition and function. , 2003, The journals of gerontology. Series A, Biological sciences and medical sciences.

[15]  E. Marini,et al.  Migration of the bioelectrical impedance vector in healthy elderly subjects. , 2003, Nutrition.

[16]  M. Valencia,et al.  Body composition by hydrometry (deuterium oxide dilution) and bioelectrical impedance in subjects aged >60 y from rural regions of Cuba, Chile and Mexico , 2003, International Journal of Obesity.

[17]  S. Draibe,et al.  Comparison of skinfold thicknesses and bioelectrical impedance analysis with dual-energy X-ray absorptiometry for the assessment of body fat in patients on long-term haemodialysis therapy. , 2003, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[18]  M. Elia,et al.  Bioelectrical impedance analysis-part II: utilization in clinical practice. , 2004, Clinical nutrition.

[19]  M. Elia,et al.  Bioelectrical impedance analysis--part I: review of principles and methods. , 2004, Clinical nutrition.

[20]  W. Gulliver,et al.  Comparison of multifrequency bioelectrical impedance analysis with dual-energy X-ray absorptiometry for assessment of percentage body fat in a large, healthy population. , 2005, The American journal of clinical nutrition.

[21]  C. Pichard,et al.  Comparison of fat-free mass and body fat in Swiss and American adults. , 2005, Nutrition.

[22]  M. Jergas,et al.  Accurate assessment of precision errors: How to measure the reproducibility of bone densitometry techniques , 2005, Osteoporosis International.

[23]  S. Klein,et al.  Aging, adiposity, and calorie restriction. , 2007, JAMA.