Liver-Assist Device With a Microfluidics-Based Vascular Bed in an Animal Model

Objective:This study evaluates a novel liver-assist device platform with a microfluidics-modeled vascular network in a femoral arteriovenous shunt in rats. Summary of Background Data:Liver-assist devices in clinical trials that use pumps to force separated plasma through packed beds of parenchymal cells exhibited significant necrosis with a negative impact on function. Methods:Microelectromechanical systems technology was used to design and fabricate a liver-assist device with a vascular network that supports a hepatic parenchymal compartment through a nanoporous membrane. Sixteen devices with rat primary hepatocytes and 12 with human HepG2/C3A cells were tested in athymic rats in a femoral arteriovenous shunt model. Several parenchymal tube configurations were evaluated for pressure profile and cell survival. The blood flow pattern and perfusion status of the devices was examined by laser Doppler scanning. Cell viability and serum protein secretion functions were assessed. Results:Femoral arteriovenous shunt was successfully established in all animals. Blood flow was homogeneous through the vascular bed and replicated native flow patterns. Survival of seeded liver cells was highly dependent on parenchymal chamber pressures. The tube configuration that generated the lowest pressure supported excellent cell survival and function. Conclusions:This device is the first to incorporate a microfluidics network in the systemic circulatory system. The microvascular network supported viability and function of liver cells in a short-term ex vivo model. Parenchymal chamber pressure generated in an arteriovenous shunt model is a critical parameter that affects viability and must be considered in future designs. The microfluidics-based vascular network is a promising platform for generating a large-scale medical device capable of augmenting liver function in a clinical setting.

[1]  Koji Fujii,et al.  Impact of portal venous pressure on regeneration and graft damage after living‐donor liver transplantation , 2005, Liver transplantation : official publication of the American Association for the Study of Liver Diseases and the International Liver Transplantation Society.

[2]  R. Tompkins,et al.  Bioengineering of liver assist devices. , 2002, Journal of hepato-biliary-pancreatic surgery.

[3]  G. Mazariegos,et al.  Safety Observations in Phase I Clinical Evaluation of the Excorp Medical Bioartificial Liver Support System after the First Four Patients , 2001, ASAIO journal.

[4]  M L Yarmush,et al.  In vitro and in vivo evaluation of albumin synthesis rate of porcine hepatocytes in a flat-plate bioreactor. , 2001, Artificial organs.

[5]  J. Vacanti,et al.  Silicon micromachining to tissue engineer branched vascular channels for liver fabrication. , 2000, Tissue engineering.

[6]  J. Vacanti,et al.  Microfabrication Technology for Vascularized Tissue Engineering , 2002 .

[7]  H. Fee,et al.  High‐output Congestive Failure From Femoral Arteriovenous Shunts for Vascular Access , 1976, Annals of Surgery.

[8]  J. Vacanti,et al.  Endothelialized Networks with a Vascular Geometry in Microfabricated Poly(dimethyl siloxane) , 2004 .

[9]  J. Park,et al.  Bioartificial liver systems: current status and future perspective. , 2005, Journal of bioscience and bioengineering.

[10]  L. Podestá,et al.  A Bioartificial Liver to Treat Severe Acute Liver Failure , 1994, Annals of surgery.

[11]  J. Vacanti,et al.  Long-term follow-up of tissue-engineered intestine after anastomosis to native small bowel. , 1999, Transplantation.

[12]  S. Bhatia,et al.  Advances in bioartificial liver devices , 2001, Hepatology.

[13]  Robert Langer,et al.  Endothelialized microvasculature based on a biodegradable elastomer. , 2005, Tissue engineering.

[14]  M. Toner,et al.  Critical issues in bioartificial liver development. , 2002, Technology and health care : official journal of the European Society for Engineering and Medicine.

[15]  D J Mooney,et al.  Survival and function of rat hepatocytes cocultured with nonparenchymal cells or sinusoidal endothelial cells on biodegradable polymers under flow conditions. , 2000, Journal of pediatric surgery.

[16]  Eli J. Weinberg,et al.  In vitro analysis of a hepatic device with intrinsic microvascular-based channels , 2008, Biomedical microdevices.

[17]  Sangeeta N Bhatia,et al.  Engineering liver therapies for the future. , 2002, Tissue engineering.

[18]  J. S. Carvalho Heterologous serum albumin as tracer for plasma volume measurements evaluated in conscious nondehydrated and 48-hour water-deprived rats. , 1989, Journal of Cardiovascular Pharmacology.

[19]  N. Sussman,et al.  The Hepatix extracorporeal liver assist device: initial clinical experience. , 1994, Artificial organs.

[20]  C. Doillon,et al.  Sealing of Polyester Prostheses with Autologous Fibrin Glue and Bone Marrow , 2000, Annals of vascular surgery.

[21]  P. Seglen Hepatocyte suspensions and cultures as tools in experimental carcinogenesis. , 1979, Journal of toxicology and environmental health.