Total Microfluidic chip for Multiplexed diagnostics (ToMMx).

Microfluidic technologies offer new platforms for biosensing in various clinical and point-of-care (POC) applications. Currently, at the clinical settings, the gold standard diagnostic platforms for multiplexed sensing are multi-step, time consuming, requiring expensive and bulky instruments with a constant need of electricity which makes them unsuitable for resource-limited or POC settings. These technologies are often limited by logistics, costly assays and regular maintenance. Although there have been several attempts to miniaturize these diagnostic platforms, they stand short of batch fabrication and they are dependent on complementary components such as syringe pumps. Here, we demonstrated the development and clinical testing of a disposable, multiplexed sensing device (ToMMx), which is a portable, high-throughput and user-friendly microfluidic platform. It was built with inexpensive plastic materials and operated manually without requiring electrical power and extensive training. We validated this platform in a small cohort of 50 clinical samples from patients with cardiovascular diseases and healthy controls. The platform is rapid and gives quantifiable results with high sensitivity, as low as 5.29 pg/mL, from only a small sample volume (4 μL). ToMMx platform was compared side-by-side with commercial ELISA kits where the total assay time is reduced 15-fold, from 5 h to 20 min. This technology platform is broadly applicable to various diseases with well-known biomarkers in diagnostics and monitoring, especially with potential future impact at the POC settings.

[1]  Il-Hoon Cho,et al.  Chemiluminometric enzyme-linked immunosorbent assays (ELISA)-on-a-chip biosensor based on cross-flow chromatography. , 2009, Analytica chimica acta.

[2]  Y. Verhertbruggen,et al.  An extended set of monoclonal antibodies to pectic homogalacturonan. , 2009, Carbohydrate research.

[3]  Marco H Hefti,et al.  Rapid, high sensitivity, point-of-care test for cardiac troponin based on optomagnetic biosensor. , 2010, Clinica chimica acta; international journal of clinical chemistry.

[4]  A. Bayés‐Genís,et al.  Multiple biomarker strategies for risk stratification in heart failure. , 2015, Clinica chimica acta; international journal of clinical chemistry.

[5]  Juan Wang,et al.  Novel biomarkers for cardiovascular risk prediction , 2017, Journal of geriatric cardiology : JGC.

[6]  James F Rusling,et al.  Magnetic particles in ultrasensitive biomarker protein measurements for cancer detection and monitoring. , 2011, Expert opinion on medical diagnostics.

[7]  Yi Lin,et al.  On-chip dual detection of cancer biomarkers directly in serum based on self-assembled magnetic bead patterns and quantum dots. , 2013, Biosensors & bioelectronics.

[8]  Emanuel Carrilho,et al.  Paper-based ELISA. , 2010, Angewandte Chemie.

[9]  W. Qiu,et al.  Integration of cell phone imaging with microchip ELISA to detect ovarian cancer HE4 biomarker in urine at the point-of-care. , 2011, Lab on a chip.

[10]  Samuel K Sia,et al.  An integrated approach to a portable and low-cost immunoassay for resource-poor settings. , 2004, Angewandte Chemie.

[11]  Zhongze Gu,et al.  Quantitative detection of multiplex cardiac biomarkers with encoded SERS nanotags on a single T line in lateral flow assay , 2018, Sensors and Actuators B: Chemical.

[12]  Taisun Kim,et al.  Multiplex detection of cardiac biomarkers , 2017 .

[13]  Michael D M Dryden,et al.  A digital microfluidic system for serological immunoassays in remote settings , 2018, Science Translational Medicine.

[14]  Antoni Bayes-Genis,et al.  NT-proBNP testing for diagnosis and short-term prognosis in acute destabilized heart failure: an international pooled analysis of 1256 patients: the International Collaborative of NT-proBNP Study. , 2006, European heart journal.

[15]  A. Jaffe,et al.  Usefulness of detectable levels of troponin, below the 99th percentile of the normal range, as a clue to the presence of underlying coronary artery disease. , 2007, The American journal of cardiology.

[16]  M. Gijs,et al.  Magnetic particle-scanning for ultrasensitive immunodetection on-chip. , 2014, Analytical chemistry.

[17]  W. Bishai,et al.  Diagnostic point-of-care tests in resource-limited settings. , 2014, The Lancet. Infectious diseases.

[18]  Hadley D Sikes,et al.  Polymerization-based signal amplification for paper-based immunoassays. , 2014, Lab on a chip.

[19]  Utkan Demirci,et al.  An integrated double-filtration microfluidic device for isolation, enrichment and quantification of urinary extracellular vesicles for detection of bladder cancer , 2017, Scientific Reports.

[20]  G. Lippi,et al.  Critical review and meta-analysis on the combination of heart-type fatty acid binding protein (H-FABP) and troponin for early diagnosis of acute myocardial infarction. , 2013, Clinical biochemistry.

[21]  Youli Zu,et al.  Multiplexed volumetric bar-chart chip for point-of-care diagnostics , 2012, Nature Communications.

[22]  M. Petzold,et al.  High-sensitive cardiac troponin, NT-proBNP, hFABP and copeptin levels in relation to glomerular filtration rates and a medical record of cardiovascular disease. , 2015, Clinical biochemistry.

[23]  Mwj Menno Prins,et al.  Rapid integrated biosensor for multiplexed immunoassays based on actuated magnetic nanoparticles. , 2009, Lab on a chip.

[24]  J. Januzzi,et al.  Biomarkers and diagnostics in heart failure. , 2013, Biochimica et biophysica acta.

[25]  A. Rai,et al.  A smartphone dongle for diagnosis of infectious diseases at the point of care , 2015, Science Translational Medicine.

[26]  H. White,et al.  State of the Art: Blood Biomarkers for Risk Stratification in Patients with Stable Ischemic Heart Disease. , 2017, Clinical chemistry.

[27]  W. Doehner Diagnostic biomarkers in cardiovascular disease: the proteomics approach. , 2012, European heart journal.

[28]  Yuping Wu,et al.  Biomarkers of Cardiovascular Disease , 2017, Disease markers.

[29]  Howard Bernstein,et al.  Microneedle-based device for the one-step painless collection of capillary blood samples , 2018, Nature Biomedical Engineering.

[30]  M. Drazner,et al.  2013 ACCF/AHA guideline for the management of heart failure: executive summary: a report of the American College of Cardiology Foundation/American Heart Association Task Force on practice guidelines. , 2013, Circulation.

[31]  Martin A M Gijs,et al.  Attomolar protein detection using a magnetic bead surface coverage assay. , 2013, Lab on a chip.

[32]  Christine F Woolley,et al.  Sensitive Detection of Cardiac Biomarkers Using a Magnetic Microbead Immunoassay. , 2015, Analytical methods : advancing methods and applications.

[33]  A. Wu,et al.  Multicenter evaluation of the Roche NT-proBNP assay and comparison to the Biosite Triage BNP assay. , 2003, Clinica chimica acta; international journal of clinical chemistry.

[34]  R. Vasan,et al.  Biomarkers of Cardiovascular Disease: Molecular Basis and Practical Considerations , 2006, Circulation.

[35]  James F Rusling,et al.  Attomolar detection of a cancer biomarker protein in serum by surface plasmon resonance using superparamagnetic particle labels. , 2011, Angewandte Chemie.

[36]  Daniel Levy,et al.  Protein Biomarkers of Cardiovascular Disease and Mortality in the Community , 2018, Journal of the American Heart Association.

[37]  Kevin A Heyries,et al.  "Print-n-Shrink" technology for the rapid production of microfluidic chips and protein microarrays. , 2009, Lab on a chip.

[38]  C. Hamm,et al.  Role of B-type natriuretic peptide (BNP) and NT-proBNP in clinical routine , 2005, Heart.

[39]  M. Becker,et al.  Comparison of the new high sensitive cardiac troponin T with myoglobin, h-FABP and cTnT for early identification of myocardial necrosis in the acute coronary syndrome , 2011, Clinical Research in Cardiology.

[40]  M. Bayindir,et al.  Robust superhydrophilic patterning of superhydrophobic ormosil surfaces for high-throughput on-chip screening applications , 2016 .

[41]  Utkan Demirci,et al.  Paper-based analytical devices for clinical diagnosis: recent advances in the fabrication techniques and sensing mechanisms , 2017, Expert review of molecular diagnostics.

[42]  C. Camargo,et al.  The N-terminal Pro-BNP investigation of dyspnea in the emergency department (PRIDE) study. , 2005, The American journal of cardiology.

[43]  Francoise F Giguel,et al.  Micro-a-fluidics ELISA for Rapid CD4 Cell Count at the Point-of-Care , 2014, Scientific Reports.

[44]  George M. Whitesides,et al.  A Paper-Based Multiplexed Transaminase Test for Low-Cost, Point-of-Care Liver Function Testing , 2012, Science Translational Medicine.

[45]  D. Giannessi Multimarker approach for heart failure management: perspectives and limitations. , 2011, Pharmacological research.

[46]  Luke P. Lee,et al.  Self-powered integrated microfluidic point-of-care low-cost enabling (SIMPLE) chip , 2017, Science Advances.

[47]  Amit Singhal,et al.  Microchip-based ultrafast serodiagnostic assay for tuberculosis , 2016, Scientific Reports.