The n-PI-method for helical cone-beam CT

A new class of acquisition schemes for helical cone-beam computed tomography (CB-CT) scanning is introduced, and their effect on the reconstruction methods is analyzed. These acquisition schemes are based on a new detector shape that is bounded by the helix. It will be shown that the data acquired with these schemes are compatible with exact reconstruction methods, and the adaptation of exact reconstruction algorithms to the new acquisition geometry is described. At the same time, the so-called PI-sufficiency condition is fulfilled. Moreover, a good fit to the acquisition requirements of the various medical applications of cone-beam CT is achieved. In contrast to other helical cone-beam acquisition and reconstruction methods, the n-PI-method introduced in this publication allows for variable pitches of the acquisition helix. This additional feature will introduce a higher flexibility into the acquisition protocols of future medical cone-beam scanners. An approximative n-PI-filtered backprojection (n-PI-FBP) reconstruction method is presented and verified. It yields convincing image quality.

[1]  M. Grass,et al.  3D cone-beam CT reconstruction for circular trajectories. , 2000, Physics in medicine and biology.

[2]  H Hu,et al.  Multi-slice helical CT: scan and reconstruction. , 1999, Medical physics.

[3]  M Defrise,et al.  Filtered backprojection reconstruction of combined parallel beam and cone beam SPECT data. , 1995, Physics in medicine and biology.

[4]  Pierre Grangeat,et al.  Cone-beam spelt with a tilted detector , 1993 .

[5]  M D Silver,et al.  High-helical-pitch, cone-beam computed tomography. , 1998, Physics in medicine and biology.

[6]  H. Tuy AN INVERSION FORMULA FOR CONE-BEAM RECONSTRUCTION* , 1983 .

[7]  Bruce D. Smith Image Reconstruction from Cone-Beam Projections: Necessary and Sufficient Conditions and Reconstruction Methods , 1985, IEEE Transactions on Medical Imaging.

[8]  Tsuneo Saito,et al.  Derivation and implementation of a cone-beam reconstruction algorithm for nonplanar orbits , 1994, IEEE Trans. Medical Imaging.

[9]  P Grangeat,et al.  Cone-beam SPECT with a tilted detector. , 1993, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[10]  Rolf Clackdoyle,et al.  A cone-beam reconstruction algorithm using shift-variant filtering and cone-beam backprojection , 1994, IEEE Trans. Medical Imaging.

[11]  M. Defrise,et al.  Single-slice rebinning method for helical cone-beam CT. , 1999, Physics in medicine and biology.

[12]  Rolf Clackdoyle,et al.  Overview of reconstruction algorithms for exact cone-beam tomography , 1994, Optics & Photonics.

[13]  M. Defrise,et al.  Cone-beam filtered-backprojection algorithm for truncated helical data. , 1998, Physics in medicine and biology.

[14]  S. Samarasekera,et al.  Exact cone beam CT with a spiral scan. , 1998, Physics in medicine and biology.

[15]  G. Wang,et al.  A general cone-beam reconstruction algorithm , 1993, IEEE Trans. Medical Imaging.

[16]  F. Natterer The Mathematics of Computerized Tomography , 1986 .

[17]  K. Taguchi,et al.  Algorithm for image reconstruction in multi-slice helical CT. , 1998, Medical physics.

[18]  Jan Eriksson,et al.  Problems and experiments in cone-beam tomography , 1998 .

[19]  P. Grangeat Mathematical framework of cone beam 3D reconstruction via the first derivative of the radon transform , 1991 .