Simulation Optimization and Experiment of R1234-ze on the Heat Pump Water Heater Storage Tank

Using fluent software simulations to analysis the temperature field and the velocity field of the equal and changing diameter condensing coils at different positions of heat pump water storage tank, and made experiment of R1234-ze on the heat pump water heater storage tank with equal and changing diameter condensing coils ,experimental analysis and simulation results show that changing diameter condensing coils make the tank temperature raise stability, which is beneficial to the stability of the system operation.