F– k Domain Imaging for Synthetic Aperture Sequential Beamforming

Spatial resolution in medical ultrasound images is a key component in image quality and an important factor for clinical diagnosis. In early systems, the lateral resolution was optimal in the focus but rapidly decreased outside the focal region. Improvements have been found in, e.g., dynamic-receive beamforming, in which the entire image is focused in receive, but this requires complex processing of element data and is not applicable for mechanical scanning of single-element images. This paper exploits the concept of two-stage beamforming based on virtual source-receivers, which reduces the front-end computational load while maintaining a similar data rate and frame rate compared to dynamic-receive beamforming. We introduce frequency-wavenumber domain data processing to obtain fast second-stage data processing while having similarly high lateral resolution as dynamic-receive beamforming and processing in time-space domain. The technique is very suitable in combination with emerging technologies such as application-specific integrated circuits (ASICs), hand-held devices, and wireless data transfer. The suggested method consists of three steps. In the first step, single-focused RF line data are shifted in time to relocate the focal point to a new origin t' = 0, z' = 0. This new origin is considered as an array of virtual source/receiver pairs, as has been suggested previously in literature. In the second step, the dataset is efficiently processed in the wavenumber-frequency domain to form an image that is in focus throughout its entire depth. In the third step, the data shift is undone to obtain a correct depth axis in the image. The method has been tested first with a single-element scanning system and second in a tissue-mimicking phantom using a linear array. In both setups, the method resulted in a -6-dB lateral point spread function (PSF) which was constant over the entire depth range, and similar to dynamic-receive beamforming and synthetic aperture sequential beamforming. The signal-to-noise ratio increased by 6 dB in both the near field and far field. These results show that the second-stage processing algorithm effectively produces a focused image over the entire depth range from a single-focused ultrasound field.

[1]  M. Tozaki,et al.  Optimal scanning technique to cover the whole breast using an automated breast volume scanner , 2010, Japanese Journal of Radiology.

[2]  A. J. Berkhout,et al.  Seismic Migration: Imaging of Acoustic Energy by Wave Field Extrapolation , 1980 .

[3]  N. de Jong,et al.  Plane-wave ultrasound beamforming using a nonuniform fast fourier transform , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[4]  Jeff Powers,et al.  Medical ultrasound systems , 2011, Interface Focus.

[5]  Arno Willem Frederik Volker Plane wave imaging using phased array , 2014 .

[6]  J. Jensen,et al.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  W.D. O'Brien,et al.  Synthetic aperture techniques with a virtual source element , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  P.D. Wilcox,et al.  The wavenumber algorithm for full-matrix imaging using an ultrasonic array , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  G. Cloutier,et al.  Stolt's f-k migration for plane wave ultrasound imaging , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[10]  Jian-yu Lu,et al.  Extended high-frame rate imaging method with limited-diffraction beams , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  Jan Baan,et al.  A wave field extrapolation approach to acoustical modeling in enclosed spaces , 1999 .

[12]  Thomas L. Szabo,et al.  Diagnostic Ultrasound Imaging: Inside Out , 2004 .

[13]  K. Boone,et al.  Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study , 1996, Medical and Biological Engineering and Computing.

[14]  K. Peacock,et al.  On the practical design of discrete velocity filters for seismic data processing , 1982 .

[15]  Jørgen Arendt Jensen,et al.  Sequential beamforming for synthetic aperture imaging. , 2013, Ultrasonics.

[16]  Generating a pencil beam from a focused transducer using Stolt migration , 2013, 2013 IEEE International Ultrasonics Symposium (IUS).

[17]  Nico de Jong,et al.  Front-end receiver electronics for a matrix transducer for 3-D transesophageal echocardiography , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[18]  J. Arendt Paper presented at the 10th Nordic-Baltic Conference on Biomedical Imaging: Field: A Program for Simulating Ultrasound Systems , 1996 .

[19]  H. Ermert,et al.  A 100-MHz ultrasound imaging system for dermatologic and ophthalmologic diagnostics , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[20]  R. Stolt MIGRATION BY FOURIER TRANSFORM , 1978 .