Structural and nonstructural performance of a seismically isolated building using stable unbonded fiber‐reinforced elastomeric isolators

Summary Stable unbonded fiber-reinforced elastomeric isolators (SU-FREIs) exhibit a characteristic horizontal softening and stiffening response, similar to other adaptive devices such as the triple friction pendulum and sliding systems with variable curvature. The transition between the softening and stiffening occurs at a displacement corresponding to a unique deformation known as full rollover. In this paper, the full rollover displacement of SU-FREIs is altered by using modified support geometry (MSG), a geometric modification of the upper and lower supports applied to tailor the hysteresis loops of the isolator. Experimental results are used to calibrate a numerical model of a base-isolated structure. The model demonstrates that the stiffening regime provides minimal restraint against displacements during events that meet or exceed the maximum considered earthquake. A parametric study revealed that the level of stiffening required to restrain displacements during large events is significant. This increase in stiffness is reflected in an increase in the response of the structure and light nonstructural components. Full rollover and MSG is considered advantageous to maintain horizontal stability and provide control over the stiffening of SU-FREIs. Copyright © 2015 John Wiley & Sons, Ltd.

[1]  Robert G. Drysdale,et al.  Lateral Response Evaluation of Fiber-Reinforced Neoprene Seismic Isolators Utilized in an Unbonded Application , 2008 .

[2]  James M. Kelly,et al.  Seismic response of light internal equipment in base‐isolated structures , 1985 .

[3]  Keri L. Ryan,et al.  Problems with Rayleigh Damping in Base-Isolated Buildings , 2008 .

[4]  Mohamed A. ElGawady,et al.  Appropriate viscous damping for nonlinear time‐history analysis of base‐isolated reinforced concrete buildings , 2013 .

[5]  Stephen A. Mahin,et al.  Approximating peak responses in seismically isolated buildings using generalized modal analysis , 2013 .

[6]  Ioannis Politopoulos,et al.  A review of adverse effects of damping in seismic isolation , 2008 .

[7]  Masayoshi Nakashima,et al.  Full‐scale shaking table test of a base‐isolated medical facility subjected to vertical motions , 2013 .

[8]  Dimitrios Konstantinidis,et al.  Seismic response of sliding equipment and contents in base‐isolated buildings subjected to broadband ground motions , 2015 .

[9]  Michael C. Constantinou,et al.  Spherical sliding isolation bearings with adaptive behavior: Theory , 2008 .

[10]  Atsuo Kakehi,et al.  Full‐scale shaking table test for examination of safety and functionality of base‐isolated medical facilities , 2011 .

[11]  Gilberto Mosqueda,et al.  Impact model for simulation of base isolated buildings impacting flexible moat walls , 2013 .

[12]  Michael C. Constantinou,et al.  Effect of viscous damping devices on the response of seismically isolated structures , 2015 .

[13]  Dimitrios Konstantinidis,et al.  The Influence of Isolator Hysteresis on Equipment Performance in Seismic Isolated Buildings , 2010 .

[14]  Eiji Sato,et al.  Predicting the displacement of triple pendulum™ bearings in a full‐scale shaking experiment using a three‐dimensional element , 2013 .

[15]  Robert G. Drysdale,et al.  Bonded versus unbonded strip fiber reinforced elastomeric isolators: Finite element analysis , 2011 .

[16]  Goodarz Ahmadi,et al.  WIND EFFECTS ON BASE-ISOLATED STRUCTURES , 1992 .

[17]  Dimitrios Konstantinidis,et al.  Finite element analysis of unbonded square fiber-reinforced elastomeric isolators (FREIs) under lateral loading in different directions , 2014 .

[18]  Gilberto Mosqueda,et al.  Experimental simulation of base‐isolated buildings pounding against moat wall and effects on superstructure response , 2012 .

[19]  James M. Kelly,et al.  The role of damping in seismic isolation , 1999 .

[20]  Michael Tait,et al.  A hybrid structural control system using a tuned liquid damper to reduce the wind induced motion of a base isolated structure , 2011 .

[21]  Petros Komodromos,et al.  Simulation of the earthquake-induced pounding of seismically isolated buildings , 2008 .

[22]  Robert G. Drysdale,et al.  Simplified analysis of a low-rise building seismically isolated with stable unbonded fiber reinforced elastomeric isolators , 2009 .

[23]  Robert G. Drysdale,et al.  Testing and modeling of square carbon fiber‐reinforced elastomeric seismic isolators , 2008 .

[24]  Tatjana Isaković,et al.  Floor response spectra in isolated structures subjected to earthquakes weaker than the design earthquake—Part I: Isolation with high-damping rubber bearings , 2011 .

[25]  E. D. Wolff,et al.  Experimental Study of Seismic Isolation Systems with Emphasis on Secondary System Response and Verification of Accuracy of Dynamic Response History Analysis Methods , 2004 .

[26]  C. S. Tsai,et al.  Finite element formulations and theoretical study for variable curvature friction pendulum system , 2003 .

[27]  Robert G. Drysdale,et al.  Parametric Study on the Response of Stable Unbonded-Fiber Reinforced Elastomeric Isolators (SU-FREIs) , 2009 .

[28]  J. Kelly Analysis of Fiber-Reinforced Elastomeric Isolators , 1999 .

[29]  Dimitrios Konstantinidis,et al.  Model of the Shear Behavior of Unbonded Fiber-Reinforced Elastomeric Isolators , 2015 .

[30]  Stephen A. Mahin,et al.  Experimental and analytical study of the bi‐directional behavior of the triple friction pendulum isolator , 2012 .

[31]  Masahiro Kurata,et al.  Disorder and damage of base‐isolated medical facilities when subjected to near‐fault and long‐period ground motions , 2014 .

[32]  G. D. Manolis,et al.  Experimental Study of Secondary Systems in Base-Isolated Structure , 1992 .

[33]  Nicos Makris,et al.  Experimental and analytical studies on the response of freestanding laboratory equipment to earthquake shaking , 2009 .

[34]  Andrei M. Reinhorn,et al.  Shake Table Testing of Triple Friction Pendulum Isolators under Extreme Conditions 13-0011.pdf , 2013 .

[35]  Dimitrios Konstantinidis,et al.  Mechanics of Rubber Bearings for Seismic and Vibration Isolation , 2011 .

[36]  Andreas Schellenberg,et al.  Structural analysis and application of wind loads to solar arrays , 2013 .

[37]  Lyan-Ywan Lu,et al.  Theory and experimental study for sliding isolators with variable curvature , 2011 .