Cytotoxicity Study of Ionophore-Based Membranes: Towards On-Body and In Vivo Ion Sensing.

We present the most complete study to date comprising in vitro cytotoxicity tests of ion-selective membranes (ISMs) in terms of cell viability, proliferation and adhesion assays with human dermal fibroblasts. ISMs were prepared with different types of plasticizers and ionophores to be tested in combination with assays that focus on the medium-term and long-term leaching of compounds. Furthermore, the ISMs were prepared in different configurations considering inner-filling solution-type electrodes, all-solid-state electrodes based on a conventional drop cast of the membrane, peeling after the preparation of a wearable sensor and detachment from a microneedle-based sensor, thus covering a wide range of membrane shapes. One of the aims of this study -other than the demonstration of the biocompatibility of various ISMs and materials tested herein- is to create an awareness in the scientific community surrounding the need to create biocompatibility assays during the very first steps of any sensor development with an intended biomedical application. This will foster meeting the requirements for subsequent on-body application of the sensor and avoiding further problems during massive validations towards the final in vivo use and commercialization of such devices.

[1]  Utkan Demirci,et al.  Advances in addressing technical challenges of point-of-care diagnostics in resource-limited settings , 2016, Expert review of molecular diagnostics.

[2]  J. Windmiller,et al.  A potentiometric tattoo sensor for monitoring ammonium in sweat. , 2013, The Analyst.

[3]  H. Krebs Chemical composition of blood plasma and serum. , 1950, Annual review of biochemistry.

[4]  P. Atanassov,et al.  Wearable Sensor System Powered by a Biofuel Cell for Detection of Lactate Levels in Sweat. , 2016, ECS journal of solid state science and technology : JSS.

[5]  Niclas Roxhed,et al.  Wearable All-Solid-State Potentiometric Microneedle Patch for Intradermal Potassium Detection. , 2018, Analytical chemistry.

[6]  T. Moriuchi-Kawakami,et al.  Ion-selective electrodes based on L-tryptophan and L-tyrosine. , 2012, Talanta.

[7]  A. Späth,et al.  Molecular recognition of organic ammonium ions in solution using synthetic receptors , 2010, Beilstein journal of organic chemistry.

[8]  Tomàs Guinovart,et al.  Wearable Potentiometric Sensors Based on Commercial Carbon Fibres for Monitoring Sodium in Sweat , 2016 .

[9]  G. Crespo,et al.  In-Line Acidification for Potentiometric Sensing of Nitrite in Natural Waters. , 2017, Analytical chemistry.

[10]  M. Meyerhoff,et al.  Real-Time Monitoring of Critical Care Analytes in the Bloodstream with Chemical Sensors: Progress and Challenges. , 2015, Annual review of analytical chemistry.

[11]  John A Rogers,et al.  Bio-Integrated Wearable Systems: A Comprehensive Review. , 2019, Chemical reviews.

[12]  A. Doosti,et al.  Comparison of human dermal fibroblasts (HDFs) growth rate in culture media supplemented with or without basic fibroblast growth factor (bFGF) , 2015, Cell and Tissue Banking.

[13]  Michael S. Roberts,et al.  Modeling the human skin barrier--towards a better understanding of dermal absorption. , 2013, Advanced drug delivery reviews.

[14]  Eric Bakker,et al.  All-solid-state potentiometric sensors with a multiwalled carbon nanotube inner transducing layer for anion detection in environmental samples. , 2015, Analytical chemistry.

[15]  Yuyin Xu,et al.  Study of the in vitro cytotoxicity testing of medical devices. , 2015, Biomedical reports.

[16]  Yufeng Zheng,et al.  In Vitro and in Vivo Studies on Biomedical Magnesium Low-Alloying with Elements Gadolinium and Zinc for Orthopedic Implant Applications. , 2018, ACS applied materials & interfaces.

[17]  Peng Wang,et al.  Improving the Biocompatibility of Polymeric Membrane Potentiometric Ion Sensors by Using a Mussel-Inspired Polydopamine Coating. , 2019, Analytical chemistry.

[18]  E. Bakker Determination of Unbiased Selectivity Coefficients of Neutral Carrier-Based Cation-Selective Electrodes , 1997 .

[19]  Philip A. Gale,et al.  Fluorinated tripodal receptors for potentiometric chloride detection in biological fluids. , 2018, Biosensors & bioelectronics.

[20]  M. Meyerhoff,et al.  Thrombogenic properties of untreated and poly(ethylene oxide)-modified polymeric matrices useful for preparing intraarterial ion-selective electrodes. , 1995, Analytical chemistry.

[21]  Christofer Toumazou,et al.  Biocompatible ion selective electrode for monitoring metabolic activity during the growth and cultivation of human cells. , 2008, Biosensors & bioelectronics.

[22]  Marc Parrilla,et al.  Wearable Potentiometric Sensors for Medical Applications , 2019, Sensors.

[23]  J M Anderson,et al.  Ion-selective membranes with low plasticizer content: electroanalytical characterization and biocompatibility studies. , 1994, Journal of biomedical materials research.

[24]  M. Cuartero,et al.  Benzodipyrrole derivates as new ionophores for anion-selective electrodes: improving potentiometric selectivity towards divalent anions. , 2011, Talanta.

[25]  J. Angello Replicative potential and the duration of the cell cycle in human fibroblasts: Coordinate stimulation by epidermal growth factor , 1992, Mechanisms of Ageing and Development.

[26]  Marc Parrilla,et al.  Wearable potentiometric ion sensors , 2019, TrAC Trends in Analytical Chemistry.

[27]  P. Bühlmann,et al.  Selectivity of potentiometric ion sensors. , 2000, Analytical chemistry.

[28]  G. J. Moody,et al.  Studies on bis(crown ether)-based ion-selective electrodes for the potentiometric determination of sodium and potassium in serum. , 1989, The Analyst.

[29]  Guang-Zhong Yang,et al.  A wearable multisensing patch for continuous sweat monitoring. , 2017, Biosensors & bioelectronics.

[30]  P. R. Miller,et al.  Microneedle-based self-powered glucose sensor , 2014 .

[31]  Samira Jafari,et al.  A Review of Molecular Mechanisms Involved in Toxicity of Nanoparticles. , 2015, Advanced pharmaceutical bulletin.

[32]  S. Nannarone,et al.  Prevention of plasticizer leaching from PVC medical devices by using organic -inorganic hybrid coatings , 2004 .

[33]  Magdalena A. Kroteń,et al.  Cereulide and valinomycin, two important natural dodecadepsipeptides with ionophoretic activities. , 2010, Polish journal of microbiology.

[34]  E. Pretsch,et al.  Modern potentiometry. , 2007, Angewandte Chemie.

[35]  I. Palchetti,et al.  Nanotoxicity assessment: A challenging application for cutting edge electroanalytical tools. , 2019, Analytica chimica acta.

[36]  Ali Javey,et al.  Wearable sweat sensors , 2018 .

[37]  A. Ivaska,et al.  Potentiometric ion sensors. , 2008, Chemical reviews.

[38]  Wei Chen,et al.  Improved In Vitro and In Vivo Biocompatibility of Graphene Oxide through Surface Modification: Poly(Acrylic Acid)-Functionalization is Superior to PEGylation. , 2016, ACS nano.

[39]  Marc Parrilla,et al.  Wearable Potentiometric Ion Patch for On-Body Electrolyte Monitoring in Sweat: Toward a Validation Strategy to Ensure Physiological Relevance. , 2019, Analytical chemistry.

[40]  T. Dubose Regulation of Potassium Homeostasis in CKD. , 2017, Advances in chronic kidney disease.

[41]  Jayoung Kim,et al.  Wearable biosensors for healthcare monitoring , 2019, Nature Biotechnology.

[42]  Ronen Polsky,et al.  Multiplexed microneedle-based biosensor array for characterization of metabolic acidosis. , 2012, Talanta.

[43]  Differentiated Paju cells have increased resistance to toxic effects of potassium ionophores. , 2004, Acta biochimica Polonica.

[44]  Benjamin C. Tang,et al.  Microneedle Electrodes Toward an Amperometric Glucose‐Sensing Smart Patch , 2014, Advanced healthcare materials.

[45]  P. Nowell,et al.  A potassium ionophore (Nigericin) inhibits stimulation of human lymphocytes by mitogens , 1978, The Journal of experimental medicine.

[46]  Elodie Boisselier,et al.  Gold nanoparticles in nanomedicine: preparations, imaging, diagnostics, therapies and toxicity. , 2009, Chemical Society reviews.

[47]  Yi Li,et al.  Silk‐Based Biomaterials in Biomedical Textiles and Fiber‐Based Implants , 2015, Advanced healthcare materials.

[48]  T. S. Strangeways,et al.  Experimental studies on the differentiation of embryonic tissues growing in vivo and in vitro.—I. The development of the undifferentiated limb-bud (a) when subcutaneously grafted into the post-embryonic chick and (b) when cultivated in vitro , 1926 .

[49]  John A Rogers,et al.  Stretchable, Multiplexed pH Sensors With Demonstrations on Rabbit and Human Hearts Undergoing Ischemia , 2014, Advanced healthcare materials.

[50]  M. Salkinoja-Salonen,et al.  The higher toxicity of cereulide relative to valinomycin is due to its higher affinity for potassium at physiological plasma concentration. , 2006, Toxicology and applied pharmacology.

[51]  Andrzej Lewenstam,et al.  New ISE-Based Apparatus for Na+, K+, Cl−, pH and Transepithelial Potential Difference Real-Time Simultaneous Measurements of Ion Transport across Epithelial Cells Monolayer–Advantages and Pitfalls , 2019, Sensors.

[52]  T. Akasaka,et al.  Biocompatibility and toxicity of nanobiomaterials 2013 , 2012 .

[53]  E. Zdrachek,et al.  Potentiometric Sensing. , 2018, Analytical chemistry.

[54]  Ikeda,et al.  Design and synthesis of a more highly selective ammonium ionophore than nonactin and its application as an ion-sensing component for an ion-selective electrode , 2000, Analytical chemistry.

[55]  S. K. Holian,et al.  A potassium ionophore (valinomycin) inhibits lymphocyte proliferation by its effects on the cell membrane. , 1976, Proceedings of the National Academy of Sciences of the United States of America.

[56]  L. C. Clark,et al.  Implanted Electroenzymatic Glucose Sensors , 1982, Diabetes Care.

[57]  Itthipon Jeerapan,et al.  Highly Stretchable Fully-Printed CNT-Based Electrochemical Sensors and Biofuel Cells: Combining Intrinsic and Design-Induced Stretchability. , 2016, Nano letters.

[58]  F. Rius,et al.  Potentiometric sensors using cotton yarns, carbon nanotubes and polymeric membranes. , 2013, The Analyst.

[59]  N. Chaniotakis,et al.  Lifetime of neutral-carrier-based liquid membranes in aqueous samples and blood and the lipophilicity of membrane components. , 1991, Analytical chemistry.

[60]  S. Navaneethan,et al.  Serum Potassium, End-Stage Renal Disease and Mortality in Chronic Kidney Disease , 2015, American Journal of Nephrology.

[61]  John A Rogers,et al.  Wearable Sensors for Biochemical Sweat Analysis. , 2019, Annual review of analytical chemistry.

[62]  Andrzej Lewenstam,et al.  Routines and Challenges in Clinical Application of Electrochemical Ion‐Sensors , 2014 .

[63]  P. Bühlmann,et al.  Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 2. Ionophores for Potentiometric and Optical Sensors. , 1998, Chemical reviews.

[64]  R. E. Gyurcsányi,et al.  Ion‐Selective Electrodes Based on Hydrophilic Ionophore‐Modified Nanopores , 2018, Angewandte Chemie.

[65]  G. Crespo,et al.  All-solid-state potentiometric sensors: A new wave for in situ aquatic research , 2018, Current Opinion in Electrochemistry.