A remote palpation instrument for laparoscopic surgery: Design and performance

This paper describes the design and performance of a prototype remote palpation instrument with tactile feedback for laparoscopic surgery. Psychophysical experiments aiming at comparing palpation with and without tactile feedback are also described. The remote palpation instrument is designed to provide the surgeon with information about size and contact force distribution. The instrument consists of a tactile sensor and a tactile display, both of which are small enough to fit onto a conventional laparoscopic grasper. Static tests showed that hardness, size and shape were successfully rendered by the tactile display. Dynamic testing showed that the bandwidth is suboptimal, but at low frequencies the output from the remote palpation instrument is useful. For the psychophysical testing, nine subjects were asked to discriminate hardness and size of objects with and without tactile feedback. The results indicated that the instrument with tactile feedback can be helpful for hardness discrimination, although the difference between the two instruments was not statistically significant for neither hardness nor size. Comparisons with earlier, similar experiments showed that the quality of the grasper and size of the forceps affected the results, indicating that there is a great potential for improving laparoscopic graspers in general.

[1]  R. H. Myers,et al.  Probability and Statistics for Engineers and Scientists , 1978 .

[2]  S. Addelman Statistics for experimenters , 1978 .

[3]  G. Honderd,et al.  Force reflection for a laparoscopic forceps , 1996, Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[4]  Antonio Bicchi,et al.  A sensor-based minimally invasive surgery tool for detecting tissutal elastic properties(003) 5323219 , 1996, Proceedings of IEEE International Conference on Robotics and Automation.

[5]  D T Pawluk,et al.  A distributed pressure sensor for biomechanical measurements. , 1998, Journal of biomechanical engineering.

[6]  T. Krummel,et al.  Tactile feedback is present during minimally invasive surgery. , 1999, Journal of the American College of Surgeons.

[7]  B. Hannaford,et al.  Force controlled and teleoperated endoscopic grasper for minimally invasive surgery-experimental performance evaluation , 1999, IEEE Transactions on Biomedical Engineering.

[8]  W. Sjoerdsma,et al.  Sensitivity of laparoscopic dissectors , 1999, Surgical Endoscopy.

[9]  D. Stoianovici,et al.  The EndoHand: comparison with standard laparoscopic instrumentation. , 1999, Journal of laparoendoscopic & advanced surgical techniques. Part A.

[10]  K. Rajanna,et al.  Tactile sensor based on piezoelectric resonance , 2002, Proceedings of IEEE Sensors.

[11]  K. Rajanna,et al.  Tactile sensor based on piezoelectric resonance , 2002, Proceedings of IEEE Sensors.

[12]  A. Castellanos,et al.  Force Feedback Plays a Significant Role in Minimally Invasive Surgery: Results and Analysis , 2005, Annals of surgery.

[13]  T. Johansen,et al.  The Role of Tactile Feedback in Laparoscopic Surgery , 2006, Surgical laparoscopy, endoscopy & percutaneous techniques.

[14]  Øyvind Stavdahl,et al.  Design and Performance of a Prototype Tactile Shape Display for Minimally Invasive Surgery , 2008 .