The Cone hip stemA prospective study of 13 patients followed for 5 years with RSA

We operated on 13 patients (14 hips) with dysplastic hips, mean age 42 (28-58) years, with a cementless Cone stem and followed them for 5 years, using the Merle d´Aubigné clinical score, conventional radiography and repeated radiostereometry analyses. The clinical scores improved markedly at 4 months and still more throughout the study. None of the patients complained of thigh pain. No stem showed radiographic subsidence, but 3 stems had radiolucent zones probably indicating fibrous ingrowth. Micromigration was measured at 4 months, 1, 2 and 5 years. The mean subsidence after 5 years was 0.27 mm and the mean posterior micromigration of the head was 0.74 mm. Most of the micromigration took place within the first 4 months. We conclude that the uncemented Cone stem used in dysplastic hips has shown a good clinical outcome so far and was found to be stable on conventional radiographs and using RSA technique.

[1]  T. Martini,et al.  The cementless PM hip arthroplasty. Four-to-seven-year results. , 1996, The Journal of bone and joint surgery. British volume.

[2]  C. Ranawat,et al.  Total hip replacement in congenital dislocation and dysplasia of the hip. , 1979, The Journal of bone and joint surgery. American volume.

[3]  J Kärrholm,et al.  Accuracy of migration analysis in hip arthroplasty. Digitized and conventional radiography, compared to radiostereometry in 51 patients. , 1995, Acta orthopaedica Scandinavica.

[4]  J. Kärrholm,et al.  Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses. , 1994, The Journal of bone and joint surgery. British volume.

[5]  J Kärrholm,et al.  Radiostereometry of hip prostheses. Review of methodology and clinical results. , 1997, Clinical orthopaedics and related research.

[6]  J. Kärrholm,et al.  Subsidence, tip, and hump micromovements of noncoated ribbed femoral prostheses. , 1993, Clinical orthopaedics and related research.

[7]  R. Denham,et al.  Loosening of the femoral component after total hip replacement. The thin black line and the sinking hip. , 1986, The Journal of bone and joint surgery. British volume.

[8]  B. Mjöberg Loosening of the cemented hip prosthesis. The importance of heat injury. , 1986, Acta orthopaedica Scandinavica. Supplementum.

[9]  Y. Sung,et al.  Total hip reconstruction in the anatomically distorted hip , 1997, Archives of Orthopaedic and Trauma Surgery.

[10]  L. Munuera,et al.  Low-friction arthroplasty in severe acetabular dysplasia. , 1993, Journal of Arthroplasty.

[11]  C. Gentz,et al.  Fracture of the femoral prosthesis in total hip replacement according to Charnley. , 1977, Acta orthopaedica Scandinavica.

[12]  R. M. D'aubigne,et al.  Functional results of hip arthroplasty with acrylic prosthesis. , 1954, The Journal of bone and joint surgery. American volume.

[13]  H. Mallmin,et al.  The Wagner revision stem for severe osteolysis. 31 hips followed for 1.5-5 years. , 1996, Acta orthopaedica Scandinavica.

[14]  C. Engh,et al.  The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty. , 1988, Clinical orthopaedics and related research.

[15]  C. Engh,et al.  Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. , 1987, The Journal of bone and joint surgery. British volume.

[16]  J. Callaghan,et al.  The porous-coated anatomic total hip prosthesis, inserted without cement. Results after five to seven years in a prospective study. , 1993, The Journal of bone and joint surgery. American volume.

[17]  G. Selvik Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system. , 1989, Acta orthopaedica Scandinavica. Supplementum.

[18]  N Sugano,et al.  The morphology of the femur in developmental dysplasia of the hip. , 1998, The Journal of bone and joint surgery. British volume.

[19]  B. M. Wroblewski,et al.  The mechanism of fracture of the femoral prosthesis in total hip replacement , 1979, International Orthopaedics.

[20]  J. Besjakov,et al.  Migration of uncemented, long-stem femoral components in revision hip arthroplasty. A 2-8 year clinical follow-up of 45 cases and radiostereometric analysis of 13 cases. , 1995, Acta orthopaedica Scandinavica.

[21]  R. Balderston,et al.  Cemented versus cementless total hip arthroplasty. A comparative study of equivalent patient populations. , 1993, Clinical orthopaedics and related research.

[22]  R B Bourne,et al.  Pain in the thigh following total hip replacement with a porous-coated anatomic prosthesis for osteoarthrosis. A five-year follow-up study. , 1994, The Journal of bone and joint surgery. American volume.

[23]  U. Wehrli,et al.  [Reaction of the bone to a cement-free SL femur revision prosthesis. Histologic findings in an autopsy specimen 5 1/2 months after surgery]. , 1989, Der Orthopade.

[24]  H. Tullos,et al.  Distal stem design and the torsional stability of cementless femoral stems. , 1995, The Journal of arthroplasty.