Single phase fault diagnosis and location in active distribution network using synchronized voltage measurement

Abstract To ensure the safe operation of the active distribution network (ADN), accurate fault diagnosis and location are crucial to improve the reliability indices and reduce the outage time. This paper proposes a characteristic model-based method for the single phase to earth fault in the ADN system. Firstly, the characteristic model of the fault factor extracts the phasor distribution characteristics of the voltage and current along the distribution feeder line and estimates the current contribution of DG units to the fault point. Based on the minimum entropy theory, the solution of nonlinear characteristic model is transformed to a single-objective optimization of the characteristic entropy and the diagnosis criteria is formulated. Then, the two-stage fault location scheme for single phase fault is proposed. The fault diagnosis stage estimates the suspicious fault section to reduce the search area and the fault location stage locates the exact fault distance. The Fibonacci search algorithm is utilized for fault location to the optimize iterative and minimize the respond time. The proposed scheme is general for all DG types and overcomes the requirement of its individual model parameters. The proposed method is validated in the IEEE 34-bus distribution test system using the phasor measurement unit (PMU). Test results of the model-based diagnosis and location method can reveal accurate fault location and rapid response at different fault impedance and small time delay comparing with the radial basis function neural network (RBF), and wavelet neural network (WNN) method.

[1]  A. M. Ariffin,et al.  Detection of faulted phase type in distribution systems based on one end voltage measurement , 2014 .

[2]  S.M. Brahma New fault-location method for a single multiterminal transmission line using synchronized phasor measurements , 2006, IEEE Transactions on Power Delivery.

[3]  Tarlochan S. Sidhu,et al.  Impedance-Based Fault Location Algorithm for Ground Faults in Series-Capacitor-Compensated Transmission Lines , 2018, IEEE Transactions on Power Delivery.

[4]  Shoaib Hussain,et al.  Fault location scheme for multi-terminal transmission lines using unsynchronized measurements , 2016 .

[5]  Damir Novosel,et al.  Unsynchronized two-terminal fault location estimation , 1996 .

[6]  Chi-Shan Yu,et al.  New Fault Impedance Computations for Unsynchronized Two-Terminal Fault-Location Computations , 2011, IEEE Transactions on Power Delivery.

[7]  Peng Li,et al.  SOP-based islanding partition method of active distribution networks considering the characteristics of DG, energy storage system and load , 2018, Energy.

[8]  K. Ramar,et al.  A combined impedance and traveling wave based fault location method for multi-terminal transmission lines , 2011 .

[9]  A. Arabali,et al.  Fault Location in Distribution Networks by Compressive Sensing , 2015, IEEE Transactions on Power Delivery.

[10]  Chi-Shan Yu,et al.  A Fault Location Technique for Two-Terminal Multisection Compound Transmission Lines Using Synchronized Phasor Measurements , 2012, IEEE Transactions on Smart Grid.

[11]  Joaquim Melendez,et al.  Comparison of impedance based fault location methods for power distribution systems , 2008 .

[12]  A.S. Bretas,et al.  Extended Fault-Location Formulation for Power Distribution Systems , 2009, IEEE Transactions on Power Delivery.

[13]  Arturo S. Bretas,et al.  Active distribution network fault location methodology: A minimum fault reactance and Fibonacci search approach , 2017 .

[14]  Ali Mohammad Ranjbar,et al.  A Novel Method for Fault Location of Transmission Lines by Wide-Area Voltage Measurements Considering Measurement Errors , 2015, IEEE Transactions on Smart Grid.

[15]  Rahman Dashti,et al.  Single phase fault location in electrical distribution feeder using hybrid method , 2016 .

[16]  Mario Paolone,et al.  Fault Detection and Faulted Line Identification in Active Distribution Networks Using Synchrophasors-Based Real-Time State Estimation , 2017, IEEE Transactions on Power Delivery.

[17]  Abbas Rabiee,et al.  Maximizing hosting capacity of renewable energy sources in distribution networks: A multi-objective and scenario-based approach , 2017 .

[18]  Ahmad Salehi Dobakhshari Wide-Area Fault Location of Transmission Lines by Hybrid Synchronized/Unsynchronized Voltage Measurements , 2018, IEEE Transactions on Smart Grid.

[19]  J Izykowski,et al.  Accurate Noniterative Fault-Location Algorithm Utilizing Two-End Unsynchronized Measurements , 2011, IEEE Transactions on Power Delivery.

[20]  Mohsen Ghasemi,et al.  Fault location in power distribution network with presence of distributed generation resources using impedance based method and applying π line model , 2017, Energy.

[21]  Dusmanta Kumar Mohanta,et al.  Transmission line fault detection and localisation methodology using PMU measurements , 2015 .

[22]  Felipe V. Lopes,et al.  Accurate Two-Terminal Transmission Line Fault Location Using Traveling Waves , 2018, IEEE Transactions on Power Delivery.

[23]  Ahmed Abdelbary,et al.  A new Fault Location Algorithm for Multi-Terminal Mixed Lines with Shared Tower and Different Voltage levels , 2018 .

[24]  Adly A. Girgis,et al.  A new fault location technique for two- and three-terminal lines , 1992 .

[25]  Zhenpo Wang,et al.  Voltage fault diagnosis and prognosis of battery systems based on entropy and Z-score for electric vehicles , 2017 .

[26]  Bo Wang,et al.  PMU-Based Fault Location Using Voltage Measurements in Large Transmission Networks , 2012, IEEE Transactions on Power Delivery.

[27]  Yun-Sik Oh,et al.  Fault detection and location in a microgrid using mathematical morphology and recursive least square methods , 2018, International Journal of Electrical Power & Energy Systems.

[28]  Marcin Sloma,et al.  Electric Properties of Graphene-Based Conductive Layers from DC Up To Terahertz Range , 2016, IEEE Transactions on Terahertz Science and Technology.

[29]  Dai Zhe,et al.  Research on WNN soft fault diagnosis for analog circuit based on adaptive UKF algorithm , 2017 .

[30]  Chunguo Fei,et al.  Fault location on high voltage transmission line by applying support vector regression with fault signal amplitudes , 2018, Electric Power Systems Research.

[31]  Gao Lin,et al.  Fault Diagnosis and Location Method for Active Distribution Network Based on Artificial Neural Network , 2018 .

[32]  Yang Zhi,et al.  A novel single-phase-to-earth fault location method for distribution network based on zero-sequence components distribution characteristics , 2018, International Journal of Electrical Power & Energy Systems.

[33]  Nader Samaan,et al.  Exact Optimal Power Dispatch in Unbalanced Distribution Systems With High PV Penetration , 2019, IEEE Transactions on Power Systems.

[34]  Yuan Liao,et al.  Accurate Transmission Line Fault Location Considering Shunt Capacitances Without Utilizing Line Parameters , 2011 .