Do Tissues From THA Revision of Highly Crosslinked UHMWPE Liners Contain Wear Debris and Associated Inflammation?

[1]  A. Del Arco,et al.  The Diagnosis of Periprosthetic Infection , 2013, The open orthopaedics journal.

[2]  R. Barrack,et al.  The Incidence of Acetabular Osteolysis in Young Patients With Conventional versus Highly Crosslinked Polyethylene , 2011, Clinical Orthopaedics and Related Research.

[3]  S. Kurtz,et al.  Distinct immunohistomorphologic changes in periprosthetic hip tissues from historical and highly crosslinked UHMWPE implant retrievals. , 2010, Journal of biomedical materials research. Part A.

[4]  L. Molfetta,et al.  Osteoclastogenesis in peripheral blood mononuclear cell cultures of periprosthetic osteolysis patients and the phenotype of T cells localized in periprosthetic tissues. , 2010, Biomaterials.

[5]  David Murray,et al.  Necrotic and inflammatory changes in metal-on-metal resurfacing hip arthroplasties , 2009, Acta orthopaedica.

[6]  L. Santambrogio,et al.  Endosomal damage and TLR2 mediated inflammasome activation by alkane particles in the generation of aseptic osteolysis. , 2009, Molecular immunology.

[7]  J. Gallo,et al.  Variation in cytokine genes can contribute to severity of acetabular osteolysis and risk for revision in patients with ABG 1 total hip arthroplasty: a genetic association study , 2009, BMC Medical Genetics.

[8]  E. Salvati,et al.  Wear is Reduced in THA Performed with Highly Cross-linked Polyethylene , 2009, Clinical orthopaedics and related research.

[9]  S. Kurtz UHMWPE Biomaterials Handbook: Ultra High Molecular Weight Polyethylene in Total Joint Replacement and Medical Devices , 2009 .

[10]  P. Revell,et al.  The combined role of wear particles, macrophages and lymphocytes in the loosening of total joint prostheses , 2008, Journal of The Royal Society Interface.

[11]  Javad Parvizi,et al.  Total hip arthroplasties: What are the reasons for revision? , 2008, International Orthopaedics.

[12]  K. Takaoka,et al.  Wear particle analysis of highly crosslinked polyethylene isolated from a failed total hip arthroplasty. , 2008, Journal of biomedical materials research. Part B, Applied biomaterials.

[13]  M. Jacobs,et al.  Hip resurfacing through an anterolateral approach. Surgical description and early review. , 2008, The Journal of bone and joint surgery. American volume.

[14]  J. Simon,et al.  Wear in conventional and highly cross-linked polyethylene cups: a 5-year follow-up study. , 2008, The Journal of arthroplasty.

[15]  R. Bourne,et al.  THE ROLE OF REGULATORY T CELLS IN PERIPROSTHETIC OSTEOLYSIS FOLLOWING PRIMARY TOTAL HIP ARTHROPLASTY. , 2008 .

[16]  A. Greenwald,et al.  Clinical performance of highly cross-linked polyethylenes in total hip arthroplasty. , 2007, The Journal of bone and joint surgery. American volume.

[17]  S. Goodman Wear particles, periprosthetic osteolysis and the immune system. , 2007, Biomaterials.

[18]  K. Knahr,et al.  Retrieval analyses of highly cross-linked polyethylene acetabular liners four and five years after implantation. , 2007, The Journal of bone and joint surgery. British volume.

[19]  J. Clohisy,et al.  Aseptic loosening of total joint replacements: mechanisms underlying osteolysis and potential therapies , 2007, Arthritis research & therapy.

[20]  H. Rubash,et al.  Assessing osteolysis with use of high-throughput protein chips. , 2007, The Journal of bone and joint surgery. American volume.

[21]  I. Clarke,et al.  Highly Crosslinked Polyethylenes in Hip Replacements: Improved Wear Performance or Paradox? , 2007 .

[22]  Guus Segal,et al.  Hydrodynamic and Thermal Behavior of Journal Bearings using Upwind Petrov-Galerkin FEM , 2007 .

[23]  A. Bayat,et al.  Genetic susceptibility to total hip arthroplasty failure: a preliminary study on the influence of matrix metalloproteinase 1, interleukin 6 polymorphisms and vitamin D receptor , 2007, Annals of the rheumatic diseases.

[24]  A. Bayat,et al.  Genetic susceptibility to total hip arthroplasty failure--positive association with mannose-binding lectin. , 2007, The Journal of arthroplasty.

[25]  D. Markel,et al.  Association between UHMWPE particle-induced inflammatory osteoclastogenesis and expression of RANKL, VEGF, and Flt-1 in vivo. , 2006, Biomaterials.

[26]  J. Fisher,et al.  Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulators. , 2006, Journal of biomedical materials research. Part A.

[27]  A. Bayat,et al.  Genetic susceptibility to hip arthroplasty failure—association with the RANK/OPG pathway , 2006, International Orthopaedics.

[28]  Peter Thomsen,et al.  Aseptic loosening, not only a question of wear: A review of different theories , 2006, Acta orthopaedica.

[29]  R. Ramakrishnan,et al.  Crosslinked polyethylene compared to conventional polyethylene in total hip replacement: Pre-clinical evaluation, in-vitro testing and prospective clinical follow-up study , 2006, Acta orthopaedica.

[30]  E. Schwarz,et al.  Periprosthetic osteolysis: an immunologist's update , 2006, Current opinion in rheumatology.

[31]  Seung-Jae Lim,et al.  Early osteolysis following second-generation metal-on-metal hip replacement. , 2005, The Journal of bone and joint surgery. American volume.

[32]  John Fisher,et al.  The role of macrophages in osteolysis of total joint replacement. , 2005, Biomaterials.

[33]  V. Goldberg,et al.  Polyethylene and titanium particles induce osteolysis by similar, lymphocyte‐independent, mechanisms , 2005, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[34]  Tomoko Matsumoto,et al.  Histological analysis and biological effects of granulation tissue around loosened hip prostheses in the development of osteolysis , 2004, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[35]  Jove Graham,et al.  Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners. , 2004, The Journal of bone and joint surgery. American volume.

[36]  L. Frommelt,et al.  Receptor activator of nuclear factor κB ligand is expressed in resident and inflammatory cells in aseptic and septic prosthesis loosening , 2003, Scandinavian journal of rheumatology.

[37]  David L. Lacey,et al.  Osteoclast differentiation and activation , 2003, Nature.

[38]  A. Unsworth,et al.  The nature and dissemination of UHMWPE wear debris retrieved from periprosthetic tissue of THR. , 2003, Journal of biomedical materials research. Part A.

[39]  P. Huie,et al.  The role of the TH1 and TH2 immune responses in loosening and osteolysis of cemented total hip replacements. , 2003, Journal of biomedical materials research. Part A.

[40]  J. Gallo,et al.  Particle disease. A comprehensive theory of periprosthetic osteolysis: a review. , 2002, Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia.

[41]  D. Williams,et al.  A study of tissue interface membranes from revision accord knee arthroplasty: the role of T lymphocytes. , 2002, Biomaterials.

[42]  L. Bonewald,et al.  Nitric Oxide and Prostaglandin E2 Production in Response to Ultra-High Molecular Weight Polyethylene Particles Depends on Osteoblast Maturation State , 2002, The Journal of bone and joint surgery. American volume.

[43]  J. Fisher,et al.  Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses , 2002, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[44]  V. Goldberg,et al.  The role of osteoclast differentiation in aseptic loosening , 2002, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[45]  M. Ries,et al.  Relationship Between Gravimetric Wear and Particle Generation in Hip Simulators: Conventional Compared with Cross-Linked Polyethylene , 2001, The Journal of bone and joint surgery. American volume.

[46]  P. Revell,et al.  Phenotypic characteristics of T lymphocytes in the interfacial tissue of aseptically loosened prosthetic joints , 2001, Journal of materials science. Materials in medicine.

[47]  D. Howie,et al.  The osteoclastogenic molecules RANKL and RANK are associated with periprosthetic osteolysis. , 2001, The Journal of bone and joint surgery. British volume.

[48]  I. Clarke,et al.  Microwear phenomena of ultrahigh molecular weight polyethylene cups and debris morphology related to gamma radiation dose in simulator study. , 2001, Journal of biomedical materials research.

[49]  W H Harris,et al.  A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award. , 2001, The Journal of arthroplasty.

[50]  S. Santavirta,et al.  No lymphokines in T-cells around loosened hip prostheses , 2001, Acta orthopaedica Scandinavica.

[51]  N. Athanasou,et al.  Histological and microbiological findings in non-infected and infected revision arthroplasty tissues , 2000, Archives of Orthopaedic and Trauma Surgery.

[52]  M. Péoc'h,et al.  Dissemination of Wear Particles to the Liver, Spleen, and Abdominal Lymph Nodes of Patients with Hip or Knee Replacement* , 2000, The Journal of bone and joint surgery. American volume.

[53]  B. Moretti,et al.  Hydroxyapatite coated with hepatocyte growth factor (HGF) stimulates human osteoblasts in vitro , 2000 .

[54]  W. Rauschning,et al.  Anatomy and surface geometry of the patellofemoral joint in the axial plane , 1999 .

[55]  C. M. Agrawal,et al.  The effect of ultra-high molecular weight polyethylene wear debris on MG63 osteosarcoma cells in vitro. , 1999, The Journal of bone and joint surgery. American volume.

[56]  F. Shen,et al.  Development of an extremely wear‐resistant ultra high molecular weight polythylene for total hip replacements , 1999, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[57]  J Fisher,et al.  Polyethylene particles of a 'critical size' are necessary for the induction of cytokines by macrophages in vitro. , 1998, Biomaterials.

[58]  M. Henry,et al.  The role of T cells in polyethylene particulate induced inflammation. , 1998, The Journal of rheumatology.

[59]  W. Maloney,et al.  Cellular profile and cytokine production at prosthetic interfaces. Study of tissues retrieved from revised hip and knee replacements. , 1998, The Journal of bone and joint surgery. British volume.

[60]  D. Murray,et al.  Human arthroplasty derived macrophages differentiate into osteoclastic bone resorbing cells , 1997, Annals of the rheumatic diseases.

[61]  M. Freeman,et al.  The size and shape of particulate polyethylene wear debris in total joint replacements , 1997, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[62]  P. Huie,et al.  Heterogeneity in cellular and cytokine profiles from multiple samples of tissue surrounding revised hip prostheses. , 1996, Journal of biomedical materials research.

[63]  D. Chappard,et al.  Migration of metal and polyethylene particles from articular prostheses may generate lymphadenopathy with histiocytosis. , 1996, Journal of biomedical materials research.

[64]  J. Zuckerman,et al.  The role of intraoperative frozen sections in revision total joint arthroplasty. , 1995, The Journal of bone and joint surgery. American volume.

[65]  C. Bragdon,et al.  Tissue response to particulate polymethylmethacrylate in mice with various immune deficiencies. , 1995, The Journal of bone and joint surgery. American volume.

[66]  P. Aspenberg,et al.  T-lymphocytes are not necessary for particulate polyethylene-induced macrophage recruitment. Histologic studies of the rat tibia. , 1994, Acta orthopaedica Scandinavica.

[67]  H. Rubash,et al.  In vivo and in vitro analysis of membranes from hip prostheses inserted without cement. , 1994, The Journal of bone and joint surgery. American volume.

[68]  T. Wright,et al.  The problem in total joint arthroplasty: aseptic loosening. , 1993, The Journal of bone and joint surgery. American volume.

[69]  H. Amstutz,et al.  The pathology of failed total joint arthroplasty. , 1982, Clinical orthopaedics and related research.

[70]  V. Pendred University of London , 1907, Nature.

[71]  P. Campbell,et al.  How has the biologic reaction to wear particles changed with newer bearing surfaces? , 2008, The Journal of the American Academy of Orthopaedic Surgeons.

[72]  M. Raška,et al.  Bone remodeling, particle disease and individual susceptibility to periprosthetic osteolysis. , 2008, Physiological research.

[73]  Hollis G Potter,et al.  The cellular and molecular biology of periprosthetic osteolysis. , 2007, Clinical orthopaedics and related research.

[74]  P. Campbell,et al.  An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements. , 2005, The Journal of bone and joint surgery. American volume.

[75]  W. Harris,et al.  A review of current cross-linked polyethylenes used in total joint arthroplasty. , 2005, Clinical orthopaedics and related research.

[76]  S. Goodman Wear particulate and osteolysis. , 2005, The Orthopedic clinics of North America.

[77]  C. Lohmann,et al.  Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. , 2005, The Journal of bone and joint surgery. American volume.

[78]  V. Saikko,et al.  Wear of conventional and cross-linked ultra-high-molecular-weight polyethylene acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulator. , 2002, Journal of biomedical materials research.

[79]  H. Rubash,et al.  Quantitative analysis of ultrahigh molecular weight polyethylene (UHMWPE) wear debris associated with total knee replacements. , 2000, Journal of biomedical materials research.

[80]  D. Hungerford,et al.  Immunohistochemical evaluation of interface membranes from failed cemented and uncemented acetabular components. , 1999, Journal of biomedical materials research.

[81]  P. Huie,et al.  The characterization of macrophages and osteoclasts in tissues harvested from revised total hip prostheses. , 1999, Journal of biomedical materials research.

[82]  D. Crook,et al.  Diagnosis of infection by frozen section during revision arthroplasty. , 1995, The Journal of bone and joint surgery. British volume.