Length-Normalized Pulse Photoplethysmography: A Noninvasive Method to Measure Blood Hemoglobin, Bronx, NY

AbstractTo determine whether blood hemoglobin concentration ([Hb]) could be measured noninvasively as the ratio of pulsatile changes in attenuation (absorbance plus scatter) of light (D) across a body part to changes in light path length (l), we measured transmission of near-infrared light (905±10 nm) through a finger, using a modified pulse oximeter, and simultaneously monitored fingertip diameter, using a sonomicrometer. In 25 subjects with [Hb] ranging from 3.1 to 18.2 gm/dl, and with normal oxygenation, average D/l ratio over 30–60 s correlated strongly with [Hb] measured by Coulter counter (r=0.84, p≪0.001), though with considerable scatter, with absolute value of differences averaging 17% of the mean. Using 12 gm/dl and 0.75 mm-1 as the lower limits of normal for [Hb] and D/l, respectively, two of nine normals had low (D/l) (78% specificity), and only one of 16 anemic subjects had borderline normal (D/l) (94%–100% sensitivity). The positive predictive value of a low (D/l) was 88% and the negative predictive value was 87.5%. With further development, this technique may reduce the need for phlebotomy, thereby reducing risks and costs and improving the experience of being a patient. © 2002 Biomedical Engineering Society. PAC2002: 8763Lk, 8714Ee

[1]  M. Frojmovic,et al.  Blood cell structure-function studies: light transmission and attenuation coefficients of suspensions of blood cells and model particles at rest and with stirring. , 1975, The Journal of laboratory and clinical medicine.

[2]  Gilwon Yoon,et al.  Noninvasive total hemoglobin measurement. , 2002, Journal of biomedical optics.

[3]  A. P. Shepherd,et al.  Role of Light Scatterng in Whole Blood Oximetry , 1986, IEEE Transactions on Biomedical Engineering.

[4]  Tatsuo Togawa,et al.  Noninvasive Measurement of Hematocrit by Electrical Admittance Plethysmography Technique , 1980, IEEE Transactions on Biomedical Engineering.

[5]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[6]  O. Khalil,et al.  Noninvasive determination of hemoglobin and hematocrit using a temperature-controlled localized reflectance tissue photometer. , 2000, Analytical biochemistry.

[7]  Innovative Non-or Minimally-Invasive Technologies for Monitoring Health and Nutritional Status in Mothers and Young Children The Role of a New Noninvasive Imaging Technology in the Diagnosis of Anemia 1 , 2 , 2001 .

[8]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[9]  A. Roggan,et al.  Optical Properties of Circulating Human Blood in the Wavelength Range 400-2500 nm. , 1999, Journal of biomedical optics.

[10]  M Spongano,et al.  Continuous on-line optical absorbance recording of blood volume changes during hemodialysis. , 2008, Artificial organs.

[11]  Gerhard Rall,et al.  Pulse oximetry: an improved in vitro model that reduces blood flow-related artifacts , 2000, IEEE Transactions on Biomedical Engineering.

[12]  S. Tanaka,et al.  Electrical admittance cuff for non-invasive and simultaneous measurement of haematocrit, arterial pressure and elasticity using volume-oscillometric method , 1994, Medical and Biological Engineering and Computing.

[13]  Joseph M. Schmitt,et al.  Measurement of blood hematocrit by dual-wavelength near-IR photoplethysmography , 1992, Photonics West - Lasers and Applications in Science and Engineering.

[14]  Robert R. Steuer,et al.  A new optical technique for monitoring hematocrit and circulating blood volume: its application in renal dialysis , 1993 .

[15]  N. M. Anderson,et al.  Light-absorbing and scattering properties of nonhaemolysed blood. , 1967, Physics in medicine and biology.

[16]  Oliver Wieben LIGHT ABSORBANCE IN PULSE OXIMETRY , 1997 .

[17]  J. M. Conis,et al.  Evaluation of a noninvasive hematocrit monitor: a new technology. , 1991, American clinical laboratory.

[18]  S J Barker,et al.  Effects of methemoglobinemia on pulse oximetry and mixed venous oximetry. , 1987, Anesthesiology.

[19]  T. Takubo,et al.  Measurement of Hemoglobin Concentrations Using the AstrimTM Noninvasive Blood Vessel Monitoring Apparatus , 2002, Acta Haematologica.

[20]  X. Fuentes-Arderiu,et al.  Glossary of terms in quantities and units in Clinical Chemistry (IUPAC-IFCC Recommendations 1996) , 1996 .

[21]  W. Zijlstra,et al.  Absorption spectra of human fetal and adult oxyhemoglobin, de-oxyhemoglobin, carboxyhemoglobin, and methemoglobin. , 1991, Clinical chemistry.

[22]  J A Brunelle,et al.  Simultaneous measurement of total hemoglobin and its derivatives in blood using CO-oximeters: analytical principles; their application in selecting analytical wavelengths and reference methods; a comparison of the results of the choices made. , 1996, Scandinavian journal of clinical and laboratory investigation. Supplementum.