Effect of curvature correction on parameters extracted from hyperspectral images

Abstract. Significance: Hyperspectral imaging (HSI) has emerged as a promising optical technique. Besides optical properties of a sample, other sample physical properties also affect the recorded images. They are significantly affected by the sample curvature and sample surface to camera distance. A correction method to reduce the artifacts is necessary to reliably extract sample properties. Aim: Our aim is to correct hyperspectral images using the three-dimensional (3D) surface data and assess how the correction affects the extracted sample properties. Approach: We propose the combination of HSI and 3D profilometry to correct the images using the Lambert cosine law. The feasibility of the correction method is presented first on hemispherical tissue phantoms and next on human hands before, during, and after the vascular occlusion test (VOT). Results: Seven different phantoms with known optical properties were created and imaged with a hyperspectral system. The correction method worked up to 60 deg inclination angle, whereas for uncorrected images the maximum angles were 20 deg. Imaging hands before, during, and after VOT shows good agreement between the expected and extracted skin physiological parameters. Conclusions: The correction method was successfully applied on the images of tissue phantoms of known optical properties and geometry and VOT. The proposed method could be applied to any reflectance optical imaging technique and should be used whenever the sample parameters need to be extracted from a curved surface sample.

[1]  Sylvain Gioux,et al.  Three-dimensional surface profile intensity correction for spatially modulated imaging. , 2009, Journal of biomedical optics.

[2]  S. Jacques,et al.  Angular dependence of HeNe laser light scattering by human dermis , 1988 .

[3]  Sylvain Gioux,et al.  Real-time, profile-corrected single snapshot imaging of optical properties. , 2015, Biomedical optics express.

[4]  Yanyu Zhao,et al.  Angle correction for small animal tumor imaging with spatial frequency domain imaging (SFDI). , 2016, Biomedical optics express.

[5]  Alain Trémeau,et al.  Three-dimensional hyperspectral imaging: A new method for human face acquisition , 2018 .

[6]  Gemma Bale,et al.  From Jöbsis to the present day: a review of clinical near-infrared spectroscopy measurements of cerebral cytochrome-c-oxidase , 2016, Journal of biomedical optics.

[7]  Martin Ehler,et al.  Direct curvature correction for noncontact imaging modalities applied to multispectral imaging. , 2010, Journal of biomedical optics.

[8]  Jie Bao,et al.  Applications of hyperspectral imaging in the detection and diagnosis of solid tumors , 2020, Translational cancer research.

[9]  E. Marcq Mie Scattering , 2021, Encyclopedia of Astrobiology.

[10]  B. Majaron,et al.  Physiological and structural characterization of human skin in vivo using combined photothermal radiometry and diffuse reflectance spectroscopy. , 2019, Biomedical optics express.

[11]  Guolan Lu,et al.  Medical hyperspectral imaging: a review , 2014, Journal of biomedical optics.

[12]  B. Hooper Optical-thermal response of laser-irradiated tissue , 1996 .

[13]  Matija Milanič,et al.  Modular multi-wavelength LED based light source for hyperspectral imaging , 2019, European Conference on Biomedical Optics.

[14]  E. K. S. Stopps,et al.  Tissue parameters determining the visual appearance of normal skin and port-wine stains , 1995, Lasers in Medical Science.

[15]  Chris E. Cooper,et al.  Re-evaluation of the near infrared spectra of mitochondrial cytochrome c oxidase: Implications for non invasive in vivo monitoring of tissues , 2014, Biochimica et biophysica acta.

[16]  P. Cerretelli,et al.  Energy metabolism and interstitial fluid displacement in human gastrocnemius during short ischemic cycles. , 1998, Journal of applied physiology.

[17]  Antonio Pifferi,et al.  Solid phantom recipe for diffuse optics in biophotonics applications: a step towards anatomically correct 3D tissue phantoms. , 2019, Biomedical optics express.

[18]  Timothy C Zhu,et al.  A review of in‐vivo optical properties of human tissues and its impact on PDT , 2011, Journal of biophotonics.

[19]  Miran Bürmen,et al.  Optical properties of PlatSil SiliGlass tissue-mimicking phantoms. , 2020, Biomedical optics express.

[20]  Nirmala Ramanujam,et al.  Monte Carlo-based inverse model for calculating tissue optical properties. Part II: Application to breast cancer diagnosis. , 2006, Applied optics.

[21]  M. Jezeršek,et al.  Simultaneous Hand–Eye and Intrinsic Calibration of a Laser Profilometer Mounted on a Robot Arm , 2021, Sensors.

[22]  Gustavo Camps-Valls,et al.  Automatic correction of the effects of the light source on spherical objects. An application to the analysis of hyperspectral images of citrus fruits , 2008 .

[23]  Ashleyj . Welch,et al.  Optical-Thermal Response of Laser-Irradiated Tissue , 1995 .

[24]  D. Wales,et al.  Optical spectroscopy for in vivo medical diagnosis—a review of the state of the art and future perspectives , 2020, Progress in Biomedical Engineering.

[25]  D Ostojic,et al.  Comparison of tissue oximeters on a liquid phantom with adjustable optical properties: an extension. , 2018, Biomedical optics express.

[26]  M. Jezeršek,et al.  Curvature and height corrections of hyperspectral images using built-in 3D laser profilometry. , 2019, Applied optics.

[27]  S. Prahl The Adding-Doubling Method , 1995 .

[28]  Martina Meinke,et al.  Determination of optical properties of human blood in the spectral range 250 to 1100 nm using Monte Carlo simulations with hematocrit-dependent effective scattering phase functions. , 2006, Journal of biomedical optics.

[29]  Valery V. Tuchin,et al.  OPTICAL PROPERTIES OF SKIN, SUBCUTANEOUS, AND MUSCLE TISSUES: A REVIEW , 2011 .

[30]  N. Ramanujam,et al.  Monte Carlo-based inverse model for calculating tissue optical properties. Part I: Theory and validation on synthetic phantoms. , 2006, Applied optics.

[31]  Sylvain Gioux,et al.  Spatial frequency domain imaging in 2019: principles, applications, and perspectives , 2019, Journal of biomedical optics.

[32]  Izumi Nishidate,et al.  Estimation of Melanin and Hemoglobin Using Spectral Reflectance Images Reconstructed from a Digital RGB Image by the Wiener Estimation Method , 2013, Sensors.

[33]  Arnoud A. Bruins,et al.  The vascular occlusion test using multispectral imaging: a validation study , 2020, Journal of Clinical Monitoring and Computing.

[34]  S. Jacques Optical properties of biological tissues: a review , 2013, Physics in medicine and biology.

[35]  Benno H. W. Hendriks,et al.  Chromophore based analyses of steady‐state diffuse reflectance spectroscopy: current status and perspectives for clinical adoption , 2015, Journal of biophotonics.

[36]  C. Zheng,et al.  Single snapshot spatial frequency domain imaging for risk stratification of diabetes and diabetic foot. , 2020, Biomedical optics express.

[37]  Ching-Cheng Chuang,et al.  Hemodynamics Study Based on Near-Infrared Optical Assessment , 2012 .

[38]  Ingemar Fredriksson,et al.  Inverse Monte Carlo method in a multilayered tissue model for diffuse reflectance spectroscopy. , 2012, Journal of biomedical optics.

[39]  Adam K. Glaser,et al.  Multiplexed Optical Imaging of Tumor-Directed Nanoparticles: A Review of Imaging Systems and Approaches , 2017, Nanotheranostics.

[40]  Walter J. Riker A Review of J , 2010 .

[41]  Ingemar Fredriksson,et al.  Machine learning for direct oxygen saturation and hemoglobin concentration assessment using diffuse reflectance spectroscopy , 2020, Journal of biomedical optics.

[42]  Igor Meglinski,et al.  Hyperspectral imaging of human skin aided by artificial neural networks. , 2019, Biomedical optics express.

[43]  Baowei Fei,et al.  Hyperspectral imaging in medical applications , 2020 .

[44]  G. Ripandelli,et al.  Optical coherence tomography. , 1998, Seminars in ophthalmology.