Passive acoustic mapping utilizing optimal beamforming in ultrasound therapy monitoring.

Passive acoustic mapping (PAM) is a promising imaging method that enables real-time three-dimensional monitoring of ultrasound therapy through the reconstruction of acoustic emissions passively received on an array of ultrasonic sensors. A passive beamforming method is presented that provides greatly improved spatial accuracy over the conventionally used time exposure acoustics (TEA) PAM reconstruction algorithm. Both the Capon beamformer and the robust Capon beamformer (RCB) for PAM are suggested as methods to reduce interference artifacts and improve resolution, which has been one of the experimental issues previously observed with TEA. Simulation results that replicate the experimental artifacts are shown to suggest that bubble interactions are the chief cause. Analysis is provided to show that these multiple bubble artifacts are generally not reduced by TEA, while Capon-based methods are able to reduce the artifacts. This is followed by experimental results from in vitro experiments and in vivo oncolytic viral therapy trials that show improved results in PAM, where RCB is able to more accurately localize the acoustic activity than TEA.

[1]  M Halliwell,et al.  Sonoporation, drug delivery, and gene therapy , 2010, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[2]  A. Austeng,et al.  Benefits of minimum-variance beamforming in medical ultrasound imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  T. D. Mast,et al.  Passive imaging with pulsed ultrasound insonations. , 2012, The Journal of the Acoustical Society of America.

[4]  Stephen J. Norton,et al.  Time exposure acoustics , 2000, IEEE Trans. Geosci. Remote. Sens..

[5]  Robert Carlisle,et al.  Ultrasound-enhanced drug delivery for cancer , 2012, Expert opinion on drug delivery.

[6]  Vasant A Salgaonkar,et al.  Passive cavitation imaging with ultrasound arrays. , 2009, The Journal of the Acoustical Society of America.

[7]  Kullervo Hynynen,et al.  Transcranial passive acoustic mapping with hemispherical sparse arrays using CT-based skull-specific aberration corrections: a simulation study , 2013, Physics in medicine and biology.

[8]  J. Capon High-resolution frequency-wavenumber spectrum analysis , 1969 .

[9]  K. Vokurka,et al.  A method for evaluating experimental data in bubble dynamics studies , 1986 .

[10]  James J. Choi,et al.  Spatiotemporal evolution of cavitation dynamics exhibited by flowing microbubbles during ultrasound exposure. , 2012, The Journal of the Acoustical Society of America.

[11]  Jian Li,et al.  Time-delay- and time-reversal-based robust capon beamformers for ultrasound imaging , 2005, IEEE Trans. Medical Imaging.

[12]  Thomas Kailath,et al.  Performance analysis of the optimum beamformer in the presence of correlated sources and its behavior under spatial smoothing , 1987, IEEE Trans. Acoust. Speech Signal Process..

[13]  Tom Leslie,et al.  Spatiotemporal monitoring of high-intensity focused ultrasound therapy with passive acoustic mapping. , 2012, Radiology.

[14]  A. Hurrell,et al.  Thin-film sparse boundary array design for passive acoustic mapping during ultrasound therapy , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  Jian Li,et al.  Multifrequency Microwave-Induced Thermal Acoustic Imaging for Breast Cancer Detection , 2007, IEEE Transactions on Biomedical Engineering.

[16]  Jian Li,et al.  Multistatic Adaptive Microwave Imaging for Early Breast Cancer Detection , 2006, IEEE Transactions on Biomedical Engineering.

[17]  Ronald A. Roy,et al.  Acoustic microcavitation: its active and passive acoustic detection. , 1991, The Journal of the Acoustical Society of America.

[18]  A. Austeng,et al.  Adaptive Beamforming Applied to Medical Ultrasound Imaging , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[19]  Miklós Gyöngy,et al.  Passive cavitation mapping for localization and tracking of bubble dynamics. , 2010, The Journal of the Acoustical Society of America.

[20]  C. Arvanitis,et al.  Cavitation-enhanced delivery of macromolecules into an obstructed vessel. , 2010, The Journal of the Acoustical Society of America.

[21]  Jian Li,et al.  On robust Capon beamforming and diagonal loading , 2003, IEEE Trans. Signal Process..

[22]  B.D. Van Veen,et al.  Beamforming: a versatile approach to spatial filtering , 1988, IEEE ASSP Magazine.

[23]  Constantin C Coussios,et al.  Cavitation-enhanced delivery of a replicating oncolytic adenovirus to tumors using focused ultrasound. , 2013, Journal of controlled release : official journal of the Controlled Release Society.

[24]  F. Gran,et al.  Broadband minimum variance beamforming for ultrasound imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[25]  Miklós Gyöngy,et al.  Passive Spatial Mapping of Inertial Cavitation During HIFU Exposure , 2010, IEEE Transactions on Biomedical Engineering.

[26]  L A Crum,et al.  A dual passive cavitation detector for localized detection of lithotripsy-induced cavitation in vitro. , 2000, The Journal of the Acoustical Society of America.

[27]  Ronald A. Roy,et al.  Applications of Acoustics and Cavitation to Noninvasive Therapy and Drug Delivery , 2008 .

[28]  Margaret S Livingstone,et al.  Combined ultrasound and MR imaging to guide focused ultrasound therapies in the brain , 2013, Physics in medicine and biology.

[29]  C. Arvanitis,et al.  Cavitation-enhanced extravasation for drug delivery. , 2011, Ultrasound in medicine & biology.