Harmonic and balance compensation using instantaneous active and reactive power control on electric railway systems

This work presents a general filtering and unbalance compensation scheme for electric traction systems. The proposed method uses an active filter controlled with the instantaneous active and reactive power, to reduce the harmonic current distortion and the negative sequence obtained by the system under unbalanced operation in steady state. The proposed filter is evaluated using open delta (V-V) and Scott transformers in the power substation. The scheme has been simulated and experimentally validated. Experimental and simulation results show the controller advantages and the applicability of the proposed method in railway systems.

[1]  Jose Restrepo,et al.  Advantages of the instantaneous reactive power definitions in three phase system measurement , 1999 .

[2]  P. Antoniewicz,et al.  Comparative study of two predictive direct power control algorithms for three-phase AC/DC converters , 2007, 2007 European Conference on Power Electronics and Applications.

[3]  G.W. Chang,et al.  Modeling characteristics of harmonic currents generated by high-speed railway traction drive converters , 2004, IEEE Transactions on Power Delivery.

[4]  Y. Mochinaga,et al.  Static negative-phase-sequence current compensator for railway power supply system , 1995 .

[5]  Miguel Ángel Rodriguez Vidal,et al.  Predictive Control Strategy for DC/AC Converters Based on Direct Power Control , 2007, IEEE Transactions on Industrial Electronics.

[6]  Fang Zhuo,et al.  A novel current detection algorithm for shunt active power filters in harmonic elimination, reactive power compensation and three-phase balancing , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[7]  J. Restrepo,et al.  A Simple Switch Selection State for SVM Direct Power Control , 2006, 2006 IEEE International Symposium on Industrial Electronics.

[8]  Bin-Kwie Chen,et al.  Three phase models of specially connected transformers , 1996 .

[9]  R. E. Morrison Power quality issues on AC traction systems , 2000, Ninth International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.00EX441).

[10]  T.G. Habetler,et al.  Optimum Space Vector Computation Technique for Direct Power Control , 2009, IEEE Transactions on Power Electronics.

[11]  T. Paga,et al.  Power System Analysis Using Space Vector Transformation , 2002, IEEE Power Engineering Review.

[12]  Peter Wolfs,et al.  Novel topology for correction of unbalanced load in single phase electric traction systems , 2002, 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289).

[13]  P. Antoniewicz,et al.  Direct Power Control of an AFE Using Predictive Control , 2008, IEEE Transactions on Power Electronics.