Service Life Estimation for the Small- and Medium-Sized Earth Grounding Grids

Service lifetime estimation for earth grounding grids as a problem or a task faced by the industry is presented. A mathematical model based on Freschi's semianalytical model to determine the performance of the earth grounding grid at a certain year after being buried is proposed. The mathematical model can also explain the performance degradation of the earth grounding grid in principle and mathematically. According to the model, a scheme to estimate the service life of the earth grounding grid is proposed. A case study is given to illustrate how the scheme works. If the estimated service life of an earth grounding grid is not satisfactory, some measures, such as cathodic protection, should be considered to extend the service lifetime of the earth grounding grid.

[1]  Ching-Yuan Bai,et al.  Corrosion behaviors and contact resistances of the low-carbon steel bipolar plate with a chromized coating containing carbides and nitrides , 2009 .

[2]  M. Pecht,et al.  Contact resistance and fretting corrosion of lead-free alloy coated electrical contacts , 2006, IEEE Transactions on Components and Packaging Technologies.

[3]  J. A. Guemes,et al.  Method for calculating the ground resistance of grounding grids using FEM , 2004, IEEE Transactions on Power Delivery.

[4]  Walter Bogaerts,et al.  Electrochemical Emission Spectroscopy for Monitoring Uniform and Localized Corrosion , 1995 .

[5]  Rong Zeng,et al.  Seasonal influences on safety of substation grounding system , 2003 .

[6]  F.P. Dawalibi,et al.  Integrated analysis software for grounding, EMF, and EMI , 1993, IEEE Computer Applications in Power.

[7]  P. K. Sen,et al.  Corrosion and steel grounding , 1990, Proceedings of the Twenty-Second Annual North American Power Symposium.

[8]  Silverio Visacro,et al.  Lightning Performance of Transmission Lines: Methodology to Design Grounding Electrodes to Ensure an Expected Outage Rate , 2015, IEEE Transactions on Power Delivery.

[9]  M. D. Bryant,et al.  Time-wise increases in contact resistance due to surface roughness and corrosion , 1990 .

[10]  Fabio Freschi,et al.  Interferences phenomena between separate grounding systems , 2014 .

[11]  F. Dawalibi Electromagnetic Fields Generated by Overhead and Buried Short Conductors Part 2 - Ground Networks , 1986, IEEE Transactions on Power Delivery.

[12]  Robert Hoerauf,et al.  Considerations in Wind Farm Grounding Designs , 2013, IEEE Transactions on Industry Applications.

[13]  F. Freschi,et al.  An effective semi-analytical method for simulating grounding grids , 2012, 48th IEEE Industrial & Commercial Power Systems Conference.

[14]  Charalambos A. Charalambous,et al.  Stray current control in DC mass transit systems , 2005, IEEE Transactions on Vehicular Technology.

[15]  Shigeru Sawada,et al.  Measurement of Contact Resistance Distribution in Fretting Corrosion Track for the Tin Plated Contacts , 2011, 2011 IEEE 57th Holm Conference on Electrical Contacts (Holm).

[16]  Sponsor,et al.  IEEE guide for safety in AC substation grounding , 2013 .

[17]  Emeka Emanuel Oguzie,et al.  Monitoring the corrosion susceptibility of mild steel in varied soil textures by corrosion product count technique , 2004 .