Simultaneous spectrophotometric determination of nitrite and nitrate by flow-injection analysis.

An automatic direct spectrophotometric method for the simultaneous determination of nitrite and nitrate by flow-injection analysis has been developed. Nitrite reacts with 3-nitroaniline in the presence of hydrochloric acid (0.96-1.8 M HCl or pH 0.5-0.7) to form a diazonium cation, which is subsequently coupled with N-(1-naphthyl)-ethylenediamine dihydrochloride to form a stable purple azo dye, the absorbance of which is measured at 535 nm. Nitrate is reduced on-line to nitrite in a copper-coated cadmium column which is then treated with azo dye reagent and the absorbance due to the sum of nitrite and nitrate is measured; nitrate is determined from the difference in absorbance values. A copper column incorporated into the reaction manifold before the copperised cadmium column not only improves the long-term accuracy, but also extends the life time of the copperised cadmium column. Various analytical parameters, such as effect of acidity (pH), flow rate, sample size, dispersion coefficient, time, temperature, reagent concentration and interfering species, were studied. The calibration graphs were rectilinear for 0.1-3.5 mug ml(-1) of NO(3) and 10 ng ml(-1)-2.2mug ml(-1) of NO(2). The method is successfully applied to some food samples (meat, flour and cheese), environmental waters (inland and surface), beer and soil samples. Up to 30 samples can be analysed per hour with a relative precision of approximately 0.1-2%.

[1]  H. V. Malmstadt,et al.  Automated determination of nitrate in waters with a reduction column in a microcomputer-based stopped-flow sample processing system , 1982 .

[2]  D. C. Hillman,et al.  The evaluation and comparison of ion chromatography, segmented flow analysis and flow injection analysis for the determination on nitrate in natural surface waters , 1989 .

[3]  Leif G. Anderson,et al.  Simultaneous spectrophotometric determination of nitrite and nitrate by flow injection analysis , 1979 .

[4]  Celio Pasquini,et al.  Flow-injection Determination Of Inorganic Forms Of Nitrogen By Gas Diffusion And Conductimetry , 1991 .

[5]  Elo Harald Hansen,et al.  Flow injection analysis : Part X. theory, techniques and trends , 1978 .

[6]  V. Cerdà,et al.  Automatic System for Simultaneous Determination of Nitrates and Nitrites in Waters , 1989 .

[7]  E. Gorodkiewicz,et al.  Simultaneous spectrophotometric determination of nitrite and nitrate in a flow-injection system , 1995 .

[8]  Á. Ríos,et al.  Configuration with internally coupled valves to overcome shortcomings in the simultaneous determination of nitrite and nitrate by flow-injection analysis. , 1988, Talanta.

[9]  B. Reis,et al.  Simultaneous determination of nitrate and nitrite by flow injection analysis , 1980 .

[10]  A. O. Rangel,et al.  Flow injection determination of nitrate in vegetables using a tubular potentiometric detector , 1995 .

[11]  H. Rathore,et al.  Spectrophotometric determination of nitrite in polluted waters using 3-nitroaniline , 1991 .

[12]  Marek Trojanowicz,et al.  Simulataneous determination of nitrite and nitrate in water using flow-injection biamperometry , 1992 .

[13]  M. Glória,et al.  Nitrate, nitrite, and volatile nitrosamines in whey-containing food products , 1995 .

[14]  J. F. Staden Automated simultaneous determination of nitrate and nitrite by pre-valve reduction of nitrate in a flow-injection system , 1982 .