An adaptive wide-area damping controller based on generalized predictive control and model identification

The wide-area damping controller (WADC), using remote signals obtained from a wide-area measurement system (WAMS) as the input, has been employed to enhance the stability of the large-scale inter-connected power system. The time delay caused by transmission of remote signals is one of the key factors influencing the whole system stability and damping performance. This paper presents an adaptive WADC based on generalized predictive control and model identification. The proposed WADC is implemented by adding its output signal to the excitation system of a selected generator. A recursive least-squares algorithm (RLSA) with a varying forgetting factor is used to identify the model of power system. Based on this model, the generalized predictive control considering control output constraints is employed. Simulations studies undertaken on a two-area four-machine power system show that the proposed adaptive WADC not only can damp the inter-area mode oscillations effectively under varying operation conditions and different disturbances, but also has better robustness against to the time delay existing in the remote signals. The comparison studies with the conventional WADC are also provided.

[1]  David W. Clarke,et al.  Generalized predictive control - Part I. The basic algorithm , 1987, Autom..

[2]  Rajat Majumder,et al.  A unified Smith predictor approach for power system damping control design using remote signals , 2005, IEEE Transactions on Control Systems Technology.

[3]  Om P. Malik,et al.  Enhancement of power system dynamic performance through an on-line self-tuning adaptive SVC controller , 2006 .

[4]  P. Kundur,et al.  Power system stability and control , 1994 .

[5]  B. W. Hogg,et al.  Robust self-tuning regulator for a synchronous generator , 1988 .

[6]  L. Mili,et al.  Power System Stability Agents Using Robust Wide-Area Control , 2002, IEEE Power Engineering Review.

[7]  James D. McCalley,et al.  Damping controller design for power system oscillations using global signals , 1996 .

[8]  R. R. Mohler,et al.  Bilinear generalized predictive control using the thyristor-controlled series-capacitor , 1994 .

[9]  O.P. Malik,et al.  Multivariable Adaptive Control of Synchronous Machines in a Multimachine Power System , 2006, IEEE Transactions on Power Systems.

[10]  J.A.L. Barreiros,et al.  A self-tuning generalized predictive power system stabilizer , 1998 .

[11]  David W. Clarke,et al.  Generalized Predictive Control - Part II Extensions and interpretations , 1987, Autom..

[12]  G.T. Heydt,et al.  Evaluation of time delay effects to wide-area power system stabilizer design , 2004, IEEE Transactions on Power Systems.

[13]  O. Malik,et al.  An Adaptive Synchronous Machine Stabilizer , 1986, IEEE Transactions on Power Systems.

[14]  Balarko Chaudhuri,et al.  Wide-area measurement-based stabilizing control of power system considering signal transmission delay , 2004 .

[15]  I. Kamwa,et al.  Control loops selection to damp inter-area oscillations of electrical networks , 2002 .

[16]  Ali Feliachi,et al.  Communication delays in wide area measurement systems , 2002, Proceedings of the Thirty-Fourth Southeastern Symposium on System Theory (Cat. No.02EX540).

[17]  Yang Zhang,et al.  Design of Wide-Area Damping Controllers for Interarea Oscillations , 2008, IEEE Transactions on Power Systems.

[18]  J.V. Milanovic,et al.  The Effectiveness of WAM Based Adaptive Supervisory Controller for Global Stabilization of Power Systems , 2007, 2007 IEEE Lausanne Power Tech.

[19]  B. Chaudhuri,et al.  Wide-area measurement-based stabilizing control of power system considering signal transmission delay , 2004, IEEE Transactions on Power Systems.

[20]  Thomas F. Coleman,et al.  Optimization Toolbox User's Guide , 1998 .