A Fixed Band Hysteresis Current Controller for Voltage Source AC Chopper

Most high-performance ac drives utilize a current controller. The controller switches a voltage source inverter (VSI) such that the motor current follows a set of reference current waveforms. Fixed-band hysteresis (FBH) current control has been widely used for the PWM inverter. We want to apply the same controller for the PWM AC chopper. The aims of the controller is to optimize the harmonic content at both input and output sides, while maintaining acceptable losses in the ac chopper and to control in wide range the fundamental output voltage. Fixed band controller has been simulated and analyzed for a single-phase AC chopper and are easily extended to three-phase systems. Simulation confirmed the advantages and the excellent performance of the modulation method applied for the AC chopper. Keywords—AC chopper, Current controller, Distortion factor, Hysteresis, Input Power Factor, PWM.

[1]  Nabil A. Ahmed,et al.  A new configuration of single-phase symmetrical PWM AC chopper voltage controller , 1999, IEEE Trans. Ind. Electron..

[2]  Ji Yanchao,et al.  An advanced harmonic elimination PWM technique for AC choppers , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[3]  B. W. Williams Asymmetrically Modulated AC Chopper , 1982, IEEE Transactions on Industrial Electronics.

[4]  Bimal K. Bose,et al.  Three-Phase AC Power Control Using Power Transistors , 1976, IEEE Transactions on Industry Applications.

[5]  Gyu-Ha Choe,et al.  Improvement of input power factor in AC choppers using asymmetrical PWM technique , 1995, IEEE Trans. Ind. Electron..

[6]  Paresh C. Sen,et al.  Comparative analysis of fixed and sinusoidal band hysteresis current controllers for voltage source inverters , 1992, IEEE Trans. Ind. Electron..

[7]  Atsuo Kawamura,et al.  Instantaneous Feedback Controlled PWM Inverter with Adaptive Hysteresis , 1984, IEEE Transactions on Industry Applications.

[8]  E. El-Bidweihy,et al.  Power Factor of AC Controllers for Inductive Loads , 1980, IEEE Transactions on Industrial Electronics and Control Instrumentation.

[9]  Gyu-Ha Choe,et al.  Asymmetrical PWM technique with harmonic elimination and power factor control in AC choppers , 1995 .

[10]  A. L. Mohamadein,et al.  Microprocessor based harmonic elimination in chopper type AC voltage regulators , 1990 .

[11]  G. N. Revankar,et al.  Symmetrically Pulse Width Modulated AC Chopper , 1977, IEEE Transactions on Industrial Electronics and Control Instrumentation.