Evening office lighting visual comfort vs. energy efficiency vs. performance

During the study presented in this article, we compared two highly energy-efficient lighting scenarios for evening office lighting (i.e. electric lighting that is typically used for approxiamately 2 h in the evening). The first of these lighting scenarios (referred to as "Reference"-scenario, Lighting Power Density or LPD of 4.5 W/m(2)) has been successfully in use in many office rooms of the Solar Energy and Building Physics Laboratory's experimental building, located on the campus of the Swiss Federal Institute of Technology in Lausanne, for several years. The second lighting scenario (referred to as "Test"-scenario, Lighting Power Density of 3.9 W/m(2)) is more energy-efficient, creates higher workplane illuminances but leads to an increased risk of discomfort glare. The aim of this study was to meticulously compare the two lighting scenarios in order to find a lighting solution for evening office lighting that offers an optimal trade-off between energy-efficiency, visual comfort and visual performance.

[1]  Alice M. Agogino,et al.  Towards embedded wireless-networked intelligent daylighting systems for commercial buildings , 2006, IEEE International Conference on Sensor Networks, Ubiquitous, and Trustworthy Computing (SUTC'06).

[2]  Mark Hinnells,et al.  Technologies to achieve demand reduction and microgeneration in buildings , 2008 .

[3]  P. R. Boyce,et al.  A field study of illuminance reduction , 2006 .

[4]  Danny H.W. Li,et al.  Lighting and energy performance for an office using high frequency dimming controls , 2006 .

[5]  Friedrich Linhart Energetic, Visual and Non-Visual Aspects of Office Lighting , 2010 .

[6]  Danny H.W. Li,et al.  An analysis of lighting energy savings and switching frequency for a daylit corridor under various indoor design illuminance levels , 2003 .

[7]  T. Åkerstedt,et al.  Subjective and objective sleepiness in the active individual. , 1990, The International journal of neuroscience.

[8]  Steve Fotios,et al.  Lighting for the classrooms of the future. Electronic classrooms: a new challenge for school lighting guidance , 2009 .

[9]  Jean-Louis Scartezzini,et al.  Minimizing lighting power density in office rooms equipped with Anidolic Daylighting Systems , 2010 .

[10]  N. H. Eklund,et al.  The Development of a Reliable, Valid, and Simple Office Lighting Survey , 1996 .

[11]  Moncef Krarti,et al.  A simplified method to estimate energy savings of artificial lighting use from daylighting , 2005 .

[12]  M. Bach,et al.  The Freiburg Visual Acuity test--automatic measurement of visual acuity. , 1996, Optometry and vision science : official publication of the American Academy of Optometry.

[13]  Jean-Louis Scartezzini,et al.  Recent research on anidolic daylighting systems: highly reflective coating materials and chronobiological properties , 2009, Optical Engineering + Applications.

[14]  Jean-Louis Scartezzini,et al.  Occupant satisfaction in office rooms equipped with Anidolic Daylighting Systems , 2008 .

[15]  Gilles Fraisse,et al.  Influence of the coupling between daylight and artificial lighting on thermal loads in office buildings , 2004 .

[16]  M. Newborough,et al.  An approach for estimating the carbon emissions associated with office lighting with a daylight contribution , 2007 .

[17]  Jean-Louis Scartezzini,et al.  Performance of Anidolic Daylighting Systems in tropical climates - Parametric studies for identification of main influencing factors , 2010 .

[18]  Ann R. Webb,et al.  Considerations for lighting in the built environment: Non-visual effects of light , 2006 .

[19]  Jan Wienold,et al.  Evaluation methods and development of a new glare prediction model for daylight environments with the use of CCD cameras , 2006 .