Surface Modification of Polypropylene Blood Oxygenator Membrane by Poly Ethylene Glycol Grafting

Blood oxygenators play key role in Extra Corporeal Membrane Oxygenator (ECMO) system using for patients with acute respiratory problems, immature fetal and also in open heart surgery. Interaction between blood and blood oxygenator polymeric membrane surface lead to fouling phenomena which have negative effect on performance of this important medical device. A modification comprising surface activation, PEG immersing and PEG graft polymerization carried out to provide acceptable blood oxygenator performance, blood compatibility and reduction in heparin consumption at the same time. Modified membranes characterized by FTIR, contact angle measurements and Atomic Force Microscopy (AFM) analyses. Blood compatibility of modified surface was also detected by SEM images. Results clearly indicate that modifying membranes by PEG is an effective way for anti-fouling properties. Water contact angel reduction from 110ْ to 72ْ shows hydrophilicity enhancement, roughness increasing from 15 to 20 and blood compatibility improvement was investigated by SEM and AFM analysis results respectively.

[1]  R. Bartlett,et al.  Extracorporeal membrane oxygenation in adult acute respiratory distress syndrome. , 2011, Critical care clinics.

[2]  M. Hollwarth Pediatric thoracic surgery , 2009, Pediatric Surgery International.

[3]  M. Stamm Polymer Surfaces and Interfaces , 2008 .

[4]  M. Müller,et al.  Polyethylene Glycol Grafting on Polypropylene Membranes for Anti-fouling Properties , 2007 .

[5]  T. Walles Clinical experience with the iLA Membrane Ventilator pumpless extracorporeal lung-assist device , 2007, Expert review of medical devices.

[6]  Gerhard Ziemer,et al.  Effect of biopassive and bioactive surface-coatings on the hemocompatibility of membrane oxygenators. , 2007, Journal of biomedical materials research. Part B, Applied biomaterials.

[7]  Zhi-Kang Xu,et al.  Flux enhancement for polypropylene microporous membrane in a SMBR by the immobilization of poly(N-vinyl-2-pyrrolidone) on the membrane surface , 2006 .

[8]  Zhi‐Kang Xu,et al.  Surface modification of polypropylene microporous membranes with a novel glycopolymer , 2005 .

[9]  Zhi‐Kang Xu,et al.  Surface modification of polypropylene microfiltration membranes by graft polymerization of N-vinyl-2-pyrrolidone , 2004 .

[10]  P. Neema,et al.  Activated Clotting Time during Cardiopulmonary Bypass: Is Repetition Necessary during Open Heart Surgery? , 2004, Asian cardiovascular & thoracic annals.

[11]  Zhi‐Kang Xu,et al.  Surface Modification of Microporous Polypropylene Membranes by Plasma-Induced Graft Polymerization of α-Allyl Glucoside , 2003 .

[12]  Junying Chen,et al.  Plasma-surface modification of biomaterials , 2002 .

[13]  M. Voorhees Oxygenator technology: the future , 1994, Perfusion.

[14]  D. Melrose Types of Heart-lung Machines used in Extra-Corporeal Circulation , 1961, Postgraduate medical journal.

[15]  M. White,et al.  Perfusion. , 2020, The American journal of nursing.

[16]  Journal of Membrane Science , 2022 .