Optical biosensors based on four different surface plasmon resonance modes: sensitivity comparison

Current surface plasmon resonance (SPR) modes based on the attenuated total reflection (ATR) method can broadly be categorized as: conventional SPR, long-range SPR (LRSPR), coupled plasmon-waveguide resonance (CPWR), and waveguide-coupled SPR (WCSPR). Although the features of optical biosensors are dependent upon their particular SPR mode, a common requirement for all biosensors utilized for biomolecular interaction analysis (BIA) is a high degree of sensitivity. The current paper presents a theoretical analysis and comparison of the sensitivity and resolution of these four types of SPR biosensors when employed in three of the most prevalent detection methods, namely angular interrogation, wavelength interrogation, and intensity measurement. This study develops a detailed understanding of the influences of various biosensor design parameters in order to enhance the sensitivity and detection limit capabilities of such devices.

[1]  Jose Melendez,et al.  Detection of Staphylococcus aureus enterotoxin B at femtomolar levels with a miniature integrated two-channel surface plasmon resonance (SPR) sensor. , 2002, Biosensors & bioelectronics.

[2]  Jiří Homola,et al.  Long-range surface plasmons for high-resolution surface plasmon resonance sensors , 2001 .

[3]  G. D. Scott,et al.  Attenuated total reflection angular spectra of a system of alternating plasma-dielectric layers. , 1978, Applied optics.

[4]  Michael J. Natan,et al.  Hydroxylamine Seeding of Colloidal Au Nanoparticles in Solution and on Surfaces , 1998 .

[5]  G. D. Scott,et al.  Attenuated total reflection angular spectra and associated resonant electromagnetic oscillations of a dielectric slab bounded by Ag films. , 1978, Applied optics.

[6]  R. G. Freeman,et al.  Preparation and Characterization of Au Colloid Monolayers , 1995 .

[7]  R. V. Van Duyne,et al.  A nanoscale optical biosensor: sensitivity and selectivity of an approach based on the localized surface plasmon resonance spectroscopy of triangular silver nanoparticles. , 2002, Journal of the American Chemical Society.

[8]  H A Macleod,et al.  Surface plasmon resonance spectroscopy as a tool for investigating the biochemical and biophysical properties of membrane protein systems. II: Applications to biological systems. , 1997, Biochimica et biophysica acta.

[9]  C. Haynes,et al.  Nanosphere lithography: Tunable localized surface plasmon resonance spectra of silver nanoparticles , 2000 .

[10]  J. M. McDonnell,et al.  Surface plasmon resonance: towards an understanding of the mechanisms of biological molecular recognition. , 2001, Current opinion in chemical biology.

[11]  Jan Greve,et al.  Surface plasmon resonance immunosensors: sensitivity considerations , 1988 .

[12]  Eric M. Yeatman,et al.  Resolution and sensitivity in surface plasmon microscopy and sensing , 1996 .

[13]  D. Sarid,et al.  Optical field enhancement by long-range surface-plasma waves. , 1982, Applied optics.

[14]  H. Raether Surface Plasmons on Smooth and Rough Surfaces and on Gratings , 1988 .

[15]  Yoshihito Ikariyama,et al.  Design and fabrication of a waveguide-coupled prism device for surface plasmon resonance sensor , 2000 .

[16]  Jan Greve,et al.  Determination of thickness and dielectric constant of thin transparent dielectric layers using surface plasmon resonance , 1991 .

[17]  Younan Xia,et al.  Increased sensitivity of surface plasmon resonance of gold nanoshells compared to that of gold solid colloids in response to environmental changes. , 2002, Analytical chemistry.

[18]  T. M. Herne,et al.  Observation of Hybridization and Dehybridization of Thiol-Tethered DNA Using Two-Color Surface Plasmon Resonance Spectroscopy , 1997 .

[19]  Michael J. Natan,et al.  SURFACE PLASMON RESONANCE OF AU COLLOID-MODIFIED AU FILMS : PARTICLE SIZE DEPENDENCE , 1999 .

[20]  K-A Lai,et al.  A novel ultrahigh-resolution surface plasmon resonance biosensor with an Au nanocluster-embedded dielectric film. , 2004, Biosensors & bioelectronics.

[21]  J. C. Quail,et al.  Long-range surface-plasmon modes in silver and aluminum films. , 1983, Optics letters.

[22]  Günter Gauglitz,et al.  Surface plasmon resonance sensors: review , 1999 .

[23]  H. E. de Bruijn,et al.  Choice of metal and wavelength for surface-plasmon resonance sensors: some considerations. , 1992, Applied optics.

[24]  D. Sarid Long-Range Surface-Plasma Waves on Very Thin Metal Films , 1981 .

[25]  T. Chinowsky,et al.  Quantitative interpretation of the response of surface plasmon resonance sensors to adsorbed films , 1998 .

[26]  Shean-Jen Chen,et al.  High-efficiency electro-optic polymer light modulator based on waveguide-coupled surface plasmon resonance , 2003, SPIE Optics + Photonics.

[27]  M. Natan,et al.  Nanoscale characterization of gold colloid monolayers:  a comparison of four techniques. , 1997, Analytical chemistry.

[28]  A. Kolomenskiǐ,et al.  Sensitivity and detection limit of concentration and adsorption measurements by laser-induced surface-plasmon resonance. , 1997, Applied optics.

[29]  B. Liedberg,et al.  Surface plasmon resonance for gas detection and biosensing , 1983 .

[30]  V. Owen Real-time optical immunosensors - a commercial reality , 1997 .

[31]  H. Macleod,et al.  Coupled plasmon-waveguide resonators: a new spectroscopic tool for probing proteolipid film structure and properties. , 1997, Biophysical journal.