Identification and characterization of plastics from small appliances and kinetic analysis of their thermally activated pyrolysis

Abstract The first step consisted in a field investigation carried out in Waste Electric and Electronic Equipment (WEEE) treatment plants coupled with a bibliographic product analysis and FT-IR spectroscopy polymers identification. Three main polymers of the thermoplastic fraction of small appliances were identified: in the external cases it was possible to find acrylonitrile-butadiene-styrene (ABS) and high impact polystyrene (HIPS), while polybutadiene terephthalate (PBT) was contained in the printed circuit boards (PCBs). Taking into account this identification, a ternary polymer mixture of ABS-HIPS-PBT was prepared as a representative sample of the thermoplastic fraction contained in WEEE (real WEEE sample). From the thermal characterization (proximate and ultimate analysis, high heating value (HHV) direct measurement and Energy-Dispersive-X-Ray-Fluorescence analysis (ED-XRF)) the only polymer whose properties sensibly differ from the analogous virgin polymer is the one contained in PCBs. A kinetic analysis of pyrolysis occurring on the three components and on their ternary mixture was performed using a thermogravimetry (TG) apparatus in argon atmosphere under non isothermal conditions. Triplicates of TG experiments at four heating rates of 2, 5, 10 and 15 K min −1 were carried out and two different model-free approaches were adopted, namely the Kissinger and Ozawa-Flynn-Wall methods in order to determine the activation energy E (as a single mean value or as a function of the degree of conversion α ). The conversion dependencies of both activation energy and pre-exponential factors were determined as well as the reaction model, representing the reaction mechanism. The suitability of the models selected was tested using the Akaike's Information Criteria (AIC) score, being the geometric model R3 the best found for pyrolysis of ABS, HIPS and real WEEE samples, while PBT sample showed an uncertainty between the R3 and the diffusion D2 model. The reaction time values to achieve the maximum pyrolysis rate in the three main components and in the real WEEE sample were also calculated.

[1]  Alan K. Burnham,et al.  ICTAC Kinetics Committee recommendations for performing kinetic computations on thermal analysis data , 2011 .

[2]  T. Bhaskar,et al.  Kinetic studies of the decomposition of flame retardant containing high-impact polystyrene , 2010 .

[3]  M. Peruggia Model Selection and Multimodel Inference: A Practical Information-Theoretic Approach (2nd ed.) , 2003 .

[4]  S. Materazzi,et al.  Crystal structure and thermoanalytical study of a cadmium(II) complex with 1-allylimidazole , 2010 .

[5]  S. Materazzi,et al.  Thermoanalytical studies of imidazole-substituted coordination compounds , 2011 .

[6]  I. Blanco,et al.  Variously substituted phenyl hepta cyclopentyl-polyhedral oligomeric silsesquioxane (ph,hcp-POSS)/polystyrene (PS) nanocomposites , 2013, Journal of Thermal Analysis and Calorimetry.

[7]  Andrew Porteous,et al.  Energy from waste incineration — a state of the art emissions review with an emphasis on public acceptability , 2001 .

[8]  David R. Anderson,et al.  Model selection and multimodel inference : a practical information-theoretic approach , 2003 .

[9]  B. Caballero,et al.  Pyrolysis of scrap tyres , 2001 .

[10]  Alexander Janz,et al.  Small WEEE: determining recyclables and hazardous substances in plastics. , 2009, Journal of hazardous materials.

[11]  Anastasia Zabaniotou,et al.  Thermochemical treatment of E-waste from small household appliances using highly pre-heated nitrogen-thermogravimetric investigation and pyrolysis kinetics , 2011 .

[12]  Anita J. Hill,et al.  Thermal degradation of acrylonitrile–butadiene–styrene (ABS) blends , 2002 .

[13]  C. Ferragina,et al.  Kinetic analysis of the oxidative decomposition in γ-zirconium and γ-titanium phosphate intercalation compounds: The case of 2,2′-bipyridyl and its copper complex formed in situ , 2008 .

[14]  Eric Forssberg,et al.  Mechanical recycling of waste electric and electronic equipment: a review. , 2003, Journal of hazardous materials.

[15]  J. Brandrup,et al.  Recycling and Recovery of Plastics , 1996 .

[16]  M. Riess,et al.  Analysis of flame retarded polymers and recycling materials. , 2000, Chemosphere.

[17]  A. Perejón,et al.  A new model for the kinetic analysis of thermal degradation of polymers driven by random scission , 2010 .

[18]  I. Marco,et al.  Pyrolysis of electrical and electronic wastes , 2008 .

[19]  T. Ozawa A New Method of Analyzing Thermogravimetric Data , 1965 .

[20]  Qingjie Guo,et al.  Pyrolysis of scrap printed circuit board plastic particles in a fluidized bed , 2010 .

[21]  Zeng Wen-ru The Degradation Kinetic Study of Polystyrene by a Combination of Non-isoThermal Differential and Integral Methods , 2006 .

[22]  Thallada Bhaskar,et al.  Thermal decomposition of flame-retarded high-impact polystyrene , 2003 .

[23]  Lieve Helsen,et al.  Review of disposal technologies for chromated copper arsenate (CCA) treated wood waste, with detailed analyses of thermochemical conversion processes. , 2005, Environmental pollution.

[24]  J. Kuipers,et al.  Kinetics of the low-temperature pyrolysis of polyethene, polypropene and polystyrene modeling, experimental determination and comparison with literature models and data , 1997 .

[25]  C. D. Doyle Kinetic analysis of thermogravimetric data , 1961 .

[26]  A. W. Coats,et al.  Kinetic Parameters from Thermogravimetric Data , 1964, Nature.

[27]  S. Materazzi,et al.  Thermoanalytical study of imidazole-substituted coordination compounds: Cu(II)- and Zn(II)-complexes of bis(1-methylimidazol-2-yl)ketone , 2013 .

[28]  S. Vyazovkin,et al.  Model-free and model-fitting approaches to kinetic analysis of isothermal and nonisothermal data , 1999 .

[29]  S. Vecchio,et al.  Lanthanide complexes of 3-methoxy-salicylaldehyde , 2010 .

[30]  Joseph H. Flynn,et al.  A quick, direct method for the determination of activation energy from thermogravimetric data , 1966 .

[31]  Hartmut Spliethoff,et al.  Thermogravimetry as a tool to classify waste components to be used for energy generation , 2004 .

[32]  Deere Avenue,et al.  Newport Corporation Statement Regarding Compliance with Directive 2011/65/EU on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (Recast) (the "RoHS Directive") , 2014 .

[33]  Mu-Hoe Yang The thermal degradation of acrylonitrile-butadiene-styrene terpolymer under various gas conditions , 2000 .

[34]  Valerio Cozzani,et al.  Formation of hydrogen bromide and organobrominated compounds in the thermal degradation of electronic boards , 2006 .

[35]  H. Akaike A new look at the statistical model identification , 1974 .

[36]  S. Bhattacharya,et al.  Thermal decomposition kinetics of tricomponent polyester/polycarbonate systems , 2011 .

[37]  J. Encinar,et al.  Pyrolysis of synthetic polymers and plastic wastes. Kinetic study , 2008 .

[38]  I. Blanco,et al.  Influence of symmetry/asymmetry of the nanoparticles structure on the thermal stability of polyhedral oligomeric silsesquioxane/polystyrene nanocomposites , 2012 .

[39]  S. Vecchio,et al.  Kinetic study of thermal breakdown of triglycerides contained in extra-virgin olive oil , 2008 .

[40]  P. Simon,et al.  IISCONVERSIONAL METHODS fundamentals, meaning and application , 2004 .

[41]  Qinghong Kong,et al.  Thermal Decomposition Kinetics of High Impact Polystyrene/Organo Fe‐montmorillonite Nanocomposites , 2012 .

[42]  H. E. Kissinger Reaction Kinetics in Differential Thermal Analysis , 1957 .

[43]  Martin Schlummer,et al.  Characterisation of polymer fractions from waste electrical and electronic equipment (WEEE) and implications for waste management. , 2007, Chemosphere.

[44]  I. Marco,et al.  Recycling of automobile shredder residues by means of pyrolysis , 2007 .