Influential Factors and Correction Method of Furfural Content in Transformer Oil

Furfural content in transformer oil is considered a credible method to evaluate the aging extent of insulation paper and is extensively applied to the aging assessment of insulation system in transformers. Clearly, the accuracy of furfural analysis is directly related to the stability of furfural in oil, which, nevertheless, may be affected by various factors. In this research, furfural was added to insulation oil directly to analyze its stability in oil firstly. Furfural contents in different conditions, such as different temperatures, copper, and oxygen atmosphere, are measured regularly. The results corroborate that the furfural content in the oil keeps constant when the oil temperature is less than 130°C without copper or oxygen; copper cannot make furfural in oil degrade without oxygen when the temperature is below 90°C. These results indicate that the furfural is stable at the common operating temperature of transformer oil (40°C ~ 70°C) as long as no oxygen is in oil. Oxygen is the main degradation cause of furfural in oil, and high temperature and copper accelerate this progress. The oxidation product of furfural in oil has been explored, which shows that the furoic acid is the main degradation product of furfural when the temperature is less than 90°C. Thus, the furoic acid content in oil can be measured as a reference to increase the accuracy of the furfural analysis.

[1]  Zhang Yan,et al.  Synthetic furfural analysis for transformer ageing , 2004, The 17th Annual Meeting of the IEEE Lasers and Electro-Optics Society, 2004. LEOS 2004..

[2]  Ruijin Liao,et al.  Thermal aging effects on the moisture equilibrium curves of mineral and mixed oil-paper insulation systems , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[3]  Yves Bertrand,et al.  Ageing diagnosis of MV/LV distribution transformers via chemical indicators in oil , 2013, 2013 IEEE Electrical Insulation Conference (EIC).

[4]  B. Pahlavanpour,et al.  The analysis of paper degradation by-products as a tool for monitoring fault conditions in oil-filled electric apparatus , 1995 .

[5]  S Eeckhoudt,et al.  Applicability of methanol as new marker for paper degradation in power transformers , 2011, IEEE Transactions on Dielectrics and Electrical Insulation.

[6]  D. Allan Recent advances in the analysis and interpretation of aged insulation from operating power transformers , 1997, Proceedings of 5th International Conference on Properties and Applications of Dielectric Materials.

[7]  Tapan Kumar Saha,et al.  Investigating the effects of oxidation and thermal degradation on electrical and chemical properties of power transformers insulation , 1999 .

[8]  Michel Duval,et al.  A review of faults detectable by gas-in-oil analysis in transformers , 2002 .

[9]  C.H. Zhang,et al.  Furfural Concentration in Transformer Oil as an Indicator of Paper Ageing: Field Measurements , 2006, 2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America.

[10]  Y. Makino,et al.  Absorption of CO/sub 2/ and CO gases and furfural in insulating oil into paper insulation in oil-immersed transformers , 1994, Proceedings of 1994 IEEE International Symposium on Electrical Insulation.

[11]  M Farzaneh,et al.  An environmentally friendly dissolved oxygen and moisture removal system for freely breathing transformers , 2010, IEEE Electrical Insulation Magazine.

[12]  J. Unsworth,et al.  Degradation of electrical insulating paper monitored with high performance liquid chromatography , 1990 .

[13]  Robert Wojcieszak,et al.  Furfural Oxidation on Gold Supported on MnO2: Influence of the Support Structure on the Catalytic Performances , 2018, Applied Sciences.

[14]  D. Linhjell,et al.  Aging of oil-impregnated paper in power transformers , 2004, IEEE Transactions on Power Delivery.

[15]  A. de Pablo Furfural and ageing: how are they related , 1999 .

[16]  I. Hohlein,et al.  Aging of cellulose at transformer service temperatures. Part 1: Influence of type of oil and air on the degree of polymerization of pressboard, dissolved gases, and furanic compounds in oil , 2005, IEEE Electrical Insulation Magazine.

[17]  Y. Zhang,et al.  Aging condition assessment of transformer oil-immersed cellulosic insulation based upon the average activation energy method , 2019, Cellulose.

[18]  L. Cheim,et al.  Furan analysis for liquid power transformers , 2012, IEEE Electrical Insulation Magazine.

[19]  M. Ali,et al.  Degradation of cellulosic insulation in power transformers. Part 2: formation of furan products in insulating oil , 2000 .