The effect of surge testing on the voltage endurance life of stator coils

Surge tests with short rise times are used to ensure turn insulation integrity in form-wound vacuum-pressure impregnated (VPI) coils prior to resin treatment. Use of this test migrated from the evaluation of fully processed generator bars and random wound stators. The dielectric properties of the insulation in these systems are fully developed at the time of testing. This is not true of "green" (unimpregnated) VPI coils. Although surge testing is a valuable manufacturing quality test, an excessive transient electric field in uncured coils may cause irreversible changes to the insulation. These changes may affect the life of the insulation system after complete impregnation and cure. This paper describes laboratory tests and finite element simulations that examine the effect of applied surge test voltage and number of applied pulses on voltage endurance (VE) life. The sympathetic voltage response in a single coil as a function of its location within a winding is described for a stator undergoing green surge testing as part of a quality assurance program. Results of VE testing and sample dissection data are presented. Test voltage was identified a more significant factor on VE life than the number of pulses applied.

[1]  D. K. Sharma,et al.  Measurement and Analysis of Surge Distribution in Motor Stator Windings , 1989, IEEE Power Engineering Review.

[2]  P. Pillai,et al.  Equivalent circuits for simulating switching surges at motor terminals , 1988 .

[3]  M. Fenger,et al.  The impact of surge voltage rise-time on PD inception voltage in random wound motors of different designs , 2001, 2001 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.01CH37225).

[4]  J.H. Dymond,et al.  Effect of surge testing on unimpregnated ground insulation of VPI stator coils , 2001, Record of Conference Papers. IEEE incorporated Industry Applications Society. Forty-Eighth Annual Conference. 2001 Petroleum and Chemical Industry Technical Conference (Cat. No.01CH37265).

[5]  D.K. Sharma,et al.  Voltage Distribution among the Coils and Turns of a Form Wound AC Rotating Machine Exposed to Impulse Voltage , 1986, IEEE Transactions on Energy Conversion.

[6]  M.K.W. Stranges,et al.  Application of statistical tools to the investigation of coil failures , 2002, Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316).

[7]  A. Pedersen,et al.  An experimental study of impulse voltage phenomena in a large AC motor , 1968 .