Large-Eddy Simulations on Indoor/Outdoor Air Quality Relationship in an Isolated Urban Building

The airflow, pollutant dispersion and penetration of outdoor pollutants indoor in an isolated urban building are investigated computationally. The computation involves solving the two-dimensional Navier — Stokes equations using large eddy simulations based on the Smagorinsky subgrid scale model. The simulations involve investigations of the phenomena of airflow and pollutant dispersion in both indoor and outdoor environments under different Reynolds numbers with distinct combinations of building height, floor height, and building width. Pollutants originate from outdoor, located at the datum level of the windward side of the building. The objective is to study how outdoor pollutants penetrate indoor and relate this pattern to different building geometric configurations. The gradual increase in Reynolds number significantly favors pollutant transportation into the indoor environment and thus eventually changes the indoor/outdoor (IO) air ratio. Moreover, the value of the IO air ratio is particularly found to be highly affected by building height due to the capability of climbing over and escaping from the roof of the building. Results also show that the IO air ratio is dependent on the position of the sampling, which has been ignored in many previous experimental works. The research work poses important questions of indoor air quality as well as field measurements of the IO parameter.

[1]  A. Chan,et al.  Indoor–outdoor relationships of particulate matter and nitrogen oxides under different outdoor meteorological conditions , 2002 .

[2]  Michael Schatzmann,et al.  Wind-tunnel and numerical modeling of flow and dispersion about several building shapes , 1999 .

[3]  Tsang-Jung Chang,et al.  Numerical Evaluation of the Effect of Traffic Pollution on Indoor Air Quality of a Naturally Ventilated Building , 2002, Journal of the Air & Waste Management Association.

[4]  S C Lee,et al.  Indoor and outdoor air quality investigation at schools in Hong Kong. , 2000, Chemosphere.

[5]  D Mark,et al.  Indoor / outdoor relationships of particulate matter in domestic homes with roadside, urban and rural locations , 2000 .

[6]  Shuzo Murakami,et al.  Chained analysis of wind tunnel test and CFD on cross ventilation of large-scale market building , 1997 .

[7]  Samir S. Ayad,et al.  Computational study of natural ventilation , 1999 .

[8]  Yoshihiko Hayashi,et al.  Numerical study on velocity-pressure field and wind forces for bluff bodies by κ-ϵ, ASM and LES , 1992 .

[9]  Ari Asmi,et al.  Indoor air measurement campaign in Helsinki, Finland 1999 – the effect of outdoor air pollution on indoor air , 2001 .

[10]  A. Mochida,et al.  On turbulent vortex shedding flow past 2D square cylinder predicted by CFD , 1995 .

[11]  Jang-Pyo Cheong,et al.  Relationships between indoor and outdoor air quality during the summer season in Korea , 1997 .

[12]  J. E. Yocom Indoor - outdoor air quality relationships: a critical review , 1982 .

[13]  Jose C. F. Pereira,et al.  Large Eddy Simulation (2D) of a Reacting Plane Mixing Layer Using Filtered Density Function Closure , 2000 .

[14]  Marek Behr,et al.  Solution techniques for the vorticity–streamfunction formulation of two‐dimensional unsteady incompressible flows , 1990 .

[15]  Shuncheng Lee,et al.  Indoor and outdoor air quality investigation at 14 public places in Hong Kong , 1999 .

[16]  D. Bouris,et al.  2D LES of vortex shedding from a square cylinder , 1999 .

[17]  P. L. Jenkins,et al.  Activity patterns of Californians: Use of and proximity to indoor pollutant sources , 1992 .

[18]  J. I Freijer,et al.  Modelling exposure of the Dutch population to air pollution , 1998 .

[19]  S. Kato,et al.  Effects of outdoor air conditions on hybrid air conditioning based on task/ambient strategy with natural and mechanical ventilation in office buildings , 2004 .

[20]  Yc C. Guo,et al.  Structures of scalar transport in 2D transitional jet diffusion flames by LES , 2003 .

[21]  Roger Perry,et al.  Indoor air quality in homes, offices and restaurants in Korean urban areas—indoor/outdoor relationships , 1997 .

[22]  A. Chan,et al.  Strategic guidelines for street canyon geometry to achieve sustainable street air quality—part II: multiple canopies and canyons , 2003 .

[23]  S. Murakami,et al.  Wind Tunnel Test on Velocity-Pressure Field of Cross-Ventilation with Open Windows , 1991 .

[24]  Yoshihide Tominaga,et al.  Velocity-pressure field of cross ventilation with open windows analyzed by wind tunnel and numerical simulation , 1992 .

[25]  U. Ghia,et al.  High-Re solutions for incompressible flow using the Navier-Stokes equations and a multigrid method , 1982 .