Novel Data Processing Approach for Deriving Blood Pressure from ECG Only

Blood pressure is one of the most valuable vital signs. Recently, the use of bio-sensors has expanded, however, the blood pressure estimation still requires additional devices. We proposed a method based on complexity analysis and machine learning techniques for blood pressure estimation using only ECG signals. Using ECG recordings from 51 different subjects by using three commercial bio-sensors and clinical equipment, we evaluated the proposed methodology by using leave-one-subject-out evaluation. The method achieves mean absolute error (MAE) of 8.2 mmHg for SBP, 8.7 mmHg for DBP and 7.9 mmHg for the MAP prediction. When models are calibrated using person-specific labelled data, the MAE decreases to 7.1 mmHg for SBP, 6.3 mmHg for DBP and 5.4 mmHg for MAP. The experimental results indicate that when a person-specific calibration data is used, the proposed method can achieve results close to a certified medical device for BP estimation.

[1]  Daniel W. Jones,et al.  The national high blood pressure education program: thirty years and counting. , 2002, Hypertension.

[2]  Shivaraman Ilango,et al.  A Non-Invasive Blood Pressure Measurement using Android Smart Phones , 2014 .

[3]  Matjaz Gams,et al.  How Accurately Can Your Wrist Device Recognize Daily Activities and Detect Falls? , 2016, Sensors.

[4]  Andrew E. Kilding,et al.  Reliability and Validity of the Zephyr™ BioHarness™ to Measure Respiratory Responses to Exercise , 2011 .

[5]  F. Bereksi-Reguig,et al.  A new system for measurement of the pulse transit time, the pulse wave velocity and its analysis , 2017 .

[6]  B. Cowley,et al.  Cognitive Collaboration Found in Cardiac Physiology: Study in Classroom Environment , 2016, PloS one.

[7]  Matjaz Gams,et al.  Monitoring stress with a wrist device using context , 2017, J. Biomed. Informatics.

[8]  Payam M. Barnaghi,et al.  A Non-invasive Wireless Monitoring Device for Children and Infants in Pre-Hospital and Acute Hospital Environments , 2017, 2017 IEEE International Conference on Internet of Things (iThings) and IEEE Green Computing and Communications (GreenCom) and IEEE Cyber, Physical and Social Computing (CPSCom) and IEEE Smart Data (SmartData).

[9]  Edward Melhuish,et al.  The Preschool Activity, Technology, Health, Adiposity, Behaviour and Cognition (PATH-ABC) cohort study: rationale and design , 2017, BMC Pediatrics.

[10]  Jeffrey M. Hausdorff,et al.  Physionet: Components of a New Research Resource for Complex Physiologic Signals". Circu-lation Vol , 2000 .

[11]  Roozbeh Jafari,et al.  BioWatch: A Noninvasive Wrist-Based Blood Pressure Monitor That Incorporates Training Techniques for Posture and Subject Variability , 2016, IEEE Journal of Biomedical and Health Informatics.

[12]  Mohan Karunanithi,et al.  Evaluation of ambulatory ECG sensors for a clinical trial on outpatient cardiac rehabilitation , 2010, IEEE/ICME International Conference on Complex Medical Engineering.

[13]  Matjaz Gams,et al.  Non-Invasive Blood Pressure Estimation from ECG Using Machine Learning Techniques , 2018, Sensors.

[14]  K. Thanushkodi,et al.  Wavelet based pulse rate and Blood pressure estimation system from ECG and PPG signals , 2011, 2011 International Conference on Computer, Communication and Electrical Technology (ICCCET).

[15]  M. Nitzan,et al.  Automatic noninvasive measurement of arterial blood pressure , 2011, IEEE Instrumentation & Measurement Magazine.

[16]  Gerwyn Hughes,et al.  Bioharness(™) multivariable monitoring device: part. I: validity. , 2012, Journal of sports science & medicine.

[17]  Esa Mervaala,et al.  Success Rate and Technical Quality of Home Polysomnography With Self-Applicable Electrode Set in Subjects With Possible Sleep Bruxism , 2018, IEEE Journal of Biomedical and Health Informatics.

[18]  W. Craelius,et al.  Trending autoregulatory indices during treatment for traumatic brain injury , 2016, Journal of Clinical Monitoring and Computing.

[19]  T. Watson,et al.  Field based reliability and validity of the bioharness™ multivariable monitoring device. , 2012, Journal of sports science & medicine.

[20]  Hsin Hsiu,et al.  A preliminary study on the correlation of frequency components between finger PPG and radial arterial BP waveforms , 2009, 2009 International Conference on Biomedical and Pharmaceutical Engineering.

[21]  Christopher M O'Connor,et al.  Treatment of Hypertension in Patients With Coronary Artery Disease: A Scientific Statement From the American Heart Association, American College of Cardiology, and American Society of Hypertension , 2015 .

[22]  Pablo Martínez-Cañada,et al.  Low-cost Remote Monitoring of Biomedical Signals , 2015, IWINAC.

[23]  G. Mitchell,et al.  Arterial stiffness and hypertension. , 2014, Hypertension.