Hysteresis effects in countercurrent gas-liquid flow limitations in a vertical tube

New experiments on air-water countercurrent flow limitations in a vertical pipe are presented. The experiments were carried out to investigate the effect of test procedure on the occurrence of the two countercurrent flow limitations; namely the onset of flooding and complete carry-up limits. The results revealed the existence of significant hysteresis effects at both limits particularly for high liquid feed rate. For low liquid feed rate, hysteresis effects were only observed at the complete carry-up limit. Some associated visual observations are reported and the results were empirically correlated and compared with recent data obtained by others. On presente de nouvelles experiences sur les limites de l'ecoulement a contre-courant air-eau dans une conduite verticale. Ces experiences ont ete menees afin d''etudier l'effet de la procedure des essais sur l'occurrence des deux limites de l'ecoulement a contre-courant, a savoir la naissance de l'engorgement et les limites maximums de charge. Les resultats revelent I'existence d'effets d'hysteresis importants aux deux limites, en particulier pour une vitesse d'alimentation en liquide elevee. Avec une faible vitesse d'alimentation en liquide, les effets d'hysteresis ont ete observes seulement a la limite maximum de charge. Certaines observations visuelles associees a ces phenomenes sont rapportees. et les resultats ont ete correles de maniere empirique puis cornpares a des donnees recentes d'autres auteurs.