Behaviour of flush end plate joints to concrete-filled steel tubular columns

Abstract This paper presents the results of an experimental program for bolted moment connection joints of circular or square concrete filled steel tubular (CFST) columns, and H-shaped steel beams using high-strength blind bolts. In order to investigate the static performance and failure modes of the blind bolted connection, an experimental program was conducted involving four sub-assemblages of cruciform beam-to-column joints subjected to monotonic loading. Moment–rotation relationships of the tested connections were obtained and their performance was evaluated in terms of their stiffness, moment capacities and ductility. The test parameters varied were the column section type and the thickness of the end plate. The results showed that the proposed blind bolted connection, which behaves in a semi-rigid and partial strength manner according to the EC3 specification, displays reasonable strength and stiffness. The rotation capacity of this type of connection to square or circular CFST columns exceeds 70 mrad and this satisfies the ductility requirements for earthquake-resistance in most aseismic regions. The blind bolted connection is shown to be a reliable and effective solution for moment-resisting composite frame structures.

[1]  Atorod Azizinamini,et al.  Experimental behavior of steel beam to CFT column connections , 2001 .

[2]  Brian Uy,et al.  The effects of partial shear connection in composite flush end plate joints Part I — experimental study , 2006 .

[3]  Silvana De Nardin,et al.  An experimental study of connections between I-beams and concrete filled steel tubular columns , 2004 .

[4]  Ahmed Ghobarah,et al.  Moment-rotation relationship of blind bolted connections for HSS columns , 1996 .

[5]  Mark A. Bradford,et al.  The effects of partial shear connection in composite flush end plate joints Part II—Analytical study and design appraisal , 2006 .

[6]  Anne Gardner,et al.  Experimental investigation of the stiffness of critical components in a moment-resisting composite connection , 2005 .

[7]  Ahmed Ghobarah,et al.  Blind Bolting W‐Shape Beams to HSS Columns , 1993 .

[8]  Ahmed Ghobarah,et al.  Dynamic response of hollow section frames with bolted moment connections , 1995 .

[9]  B. S. Choo,et al.  Behaviour of flush end-plate composite connections with unbalanced moment and variable shear/moment ratios—I. Experimental behaviour , 1996 .

[10]  Lap-Loi Chung,et al.  Seismic behavior of bolted beam-to-column connections for concrete filled steel tube , 2005 .

[11]  Paulo J. S. Cruz,et al.  Experimental behaviour of end-plate beam-to-column composite joints under monotonical loading , 2001 .

[12]  K. F. Chung,et al.  Composite column design to Eurocode 4 : based on DD ENV 1994-1-1: 1994 Eurocode 4: design of composite steel and concrete structures: part 1.1: general rules and rules for buildings , 1994 .

[13]  Yousef.M. Alostaz,et al.  Experimental Behavior of Connections to Concrete-filled Steel Tubes , 1998 .

[14]  S Klippel Recent Design Developments with Blind Mechanically Operated Bolt Systems for Use with Hollow Section Steelwork , 1998 .

[15]  N. E. Shanmugam,et al.  Composite joints subject to reversal of loading—Part 1: experimental study , 2004 .

[16]  Chanakya Arya,et al.  Eurocode 3: Design of steel structures , 2018, Design of Structural Elements.

[17]  Anne Gardner,et al.  Feasibility study for blind-bolted connections to concrete-filled circular steel tubular columns , 2006 .