A phase aberration correction method for ultrasound imaging

A computationally efficient method for phase aberration correction in ultrasound imaging is presented. The method is based on time delay estimation via minimization of the sum of absolute differences between radio frequency samples of adjacent array elements. Effects of averaging estimated aberration patterns over scan angle and truncation to a single bit wordlength are examined. Phase distortions due to near-field inhomogeneities are simulated using silicone rubber aberrators. Performance of the method is tested using experimental data. Simulation studies addressing different factors affecting efficiency of the method, such as the number of iterations, window length, and the number of scan angles used for averaging, are presented. Images of a standard resolution phantom are reconstructed and used for qualitative testing.<<ETX>>

[1]  B. Steinberg,et al.  Effect of multipath and scattering on array gain of a large adaptive beam forming phased array , 1985 .

[2]  D C Sullivan,et al.  In vivo measurements of ultrasonic beam distortion in the breast. , 1991, Ultrasonic imaging.

[3]  G. Carter,et al.  On the simulation of a class of time delay estimation algorithms , 1981 .

[4]  M. O'Donnell,et al.  Phase-aberration correction using signals from point reflectors and diffuse scatterers: measurements , 1988, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  G. Trahey,et al.  In Vivo Measurements of Ultrasonic Beam Distortion in the Breast , 1991 .

[6]  Petros Maragos Morphological correlation and mean absolute error criteria , 1989, International Conference on Acoustics, Speech, and Signal Processing,.

[7]  D Rachlin Direct estimation of aberrating delays in pulse-echo imaging systems. , 1990, The Journal of the Acoustical Society of America.

[8]  K. Takamizawa,et al.  An investigation of wavefront distortion correction: correction using averaged phase information and the effect of correction in one and two dimensions (medical US imaging) , 1991, IEEE 1991 Ultrasonics Symposium,.

[9]  G. Trahey,et al.  Comparisons of image quality factors for phase aberration correction with diffuse and point targets: theory and experiments , 1991, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  Takuso Sato,et al.  Imaging through an inhomogeneous layer by least‐mean‐square error fitting , 1984 .

[11]  Raoul Mallart,et al.  The van Cittert–Zernike theorem in pulse echo measurements , 1991 .

[12]  Abdullah Atalar,et al.  Adaptive digital beamforming for phased array ultrasound imaging (medical US imaging) , 1991, IEEE 1991 Ultrasonics Symposium,.

[13]  Gregg E. Trahey,et al.  An evaluation of transducer design and algorithm performance for two dimensional phase aberration correction , 1991, IEEE 1991 Ultrasonics Symposium,.

[14]  M. O’Donnell,et al.  Phase-aberration correction using signals from point reflectors and diffuse scatterers: basic principles , 1988, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  M. O'Donnell,et al.  Aberration correction on a two-dimensional anisotropic phased array (medical US imaging) , 1991, IEEE 1991 Ultrasonics Symposium,.

[16]  Harvey F. Silverman,et al.  A Class of Algorithms for Fast Digital Image Registration , 1972, IEEE Transactions on Computers.

[17]  Mathias Fink,et al.  Optimal focusing through aberrating media: a comparison between time reversal mirror and time delay correction techniques , 1991, IEEE 1991 Ultrasonics Symposium,.

[18]  L.N. Bohs,et al.  A novel method for angle independent ultrasonic imaging of blood flow and tissue motion , 1991, IEEE Transactions on Biomedical Engineering.

[19]  M. O'Donnell,et al.  Correlation-based aberration correction in the presence of inoperable elements , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[20]  G E Trahey,et al.  Phased array ultrasound imaging through planar tissue layers. , 1986, Ultrasound in medicine & biology.