Fluorescence cross sections of bioaerosols and suspended biological agents.

Laser-induced fluorescence is used to investigate fluorescence properties of unwashed Bacillus thuringiensis and Bacillus subtilis spores, ovalbumin, and washed bacteriophage MS2. A fluorescence detector is calibrated to obtain absolute fluorescence cross sections. Fluorescence maps of biological aerosols and suspensions are measured at a wide excitation range from 210 to 419 nm and a wide detection range from 315 to 650 nm. The dominant features of the measured spectra are the amino acid peaks, having excitation maxima at 220 and 280 nm. The peaks are similar for the bacterial spores, both for aerosols and suspensions, whereas the peaks are shifted toward the shorter emission wavelengths for the suspended ovalbumin and MS2. Moreover, the fluorescence emission, excited above 320 nm is more intensive for the aerosols than the suspensions.

[1]  Yong-Le Pan,et al.  Real-time measurement of fluorescence spectra from single airborne biological particles , 1999 .

[2]  P. Wyatt Differential light scattering: a physical method for identifying living bacterial cells. , 1968, Applied optics.

[3]  Jerri Tribble,et al.  Bacteria identification of otitis media with fluorescence spectroscopy , 1994, Lasers in surgery and medicine.

[4]  A. Westphal,et al.  Kinetics of size changes of individual Bacillus thuringiensis spores in response to changes in relative humidity , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[5]  S. C. Hill,et al.  Conditional-firing aerosol-fluorescence spectrum analyzer for individual airborne particles with pulsed 266-nm laser excitation. , 1996, Optics letters.

[6]  Tanja Popovic,et al.  Bacillus anthracis Aerosolization Associated with a Contaminated Mail Sorting Machine , 2002, Emerging infectious diseases.

[7]  Gustav Schweiger,et al.  Physical and chemical (Raman) characterization of bioaerosols — pollen , 1999 .

[8]  Chang,et al.  Enhanced backward-directed multiphoton-excited fluorescence from dielectric microcavities , 2000, Physical review letters.

[9]  M. Yavuz Corapcioglu,et al.  Delineating the Specific Influence of Virus Isoelectric Point and Size on Virus Adsorption and Transport through Sandy Soils , 1998, Applied and Environmental Microbiology.

[10]  Robert R Alfano,et al.  Native fluorescence and excitation spectroscopic changes in Bacillus subtilis and Staphylococcus aureus bacteria subjected to conditions of starvation. , 2003, Applied optics.

[11]  K. Mortelmans,et al.  Spectrally resolved absolute fluorescence cross sections for bacillus spores. , 1997, Applied optics.

[12]  W. Nelson,et al.  Steady-State and Decay Characteristics of Protein Tryptophan Fluorescence from Bacteria , 1986 .

[13]  Yong-Le Pan,et al.  Backward-enhanced fluorescence from clusters of microspheres and particles of tryptophan. , 2002, Applied optics.

[14]  L. Morawska,et al.  Performance Evaluation of the UVAPS in Measuring Biological Aerosols: Fluorescence Spectra from NAD(P)H Coenzymes and Riboflavin , 2004 .

[15]  M. Hugh-jones,et al.  The Sverdlovsk anthrax outbreak of 1979. , 1994, Science.

[16]  Sandra E Thompson,et al.  Identification of Bacterial Spores Using Statistical Analysis of Fourier Transform Infrared Photoacoustic Spectroscopy Data , 2003, Applied spectroscopy.

[17]  Burt V. Bronk,et al.  Variability of Steady-State Bacterial Fluorescence with Respect to Growth Conditions , 1993 .

[18]  Vasanthi Sivaprakasam,et al.  Multiple UV wavelength excitation and fluorescence of bioaerosols , 2004, SPIE Optics East.

[19]  Yung-sung Cheng,et al.  Detection of bioaerosols using multiwavelength UV fluorescence spectroscopy , 1999 .

[20]  F. Castellino,et al.  Examination of the dissociation of multichain proteins in guanidine hydrochloride by membrane osmometry. , 1968, Biochemistry.

[21]  S. Delgado,et al.  Reagentless identification of human bifidobacteria by intrinsic fluorescence. , 2007, Journal of microbiological methods.

[22]  Yong-Le Pan,et al.  Single‐particle laser‐induced‐fluorescence spectra of biological and other organic‐carbon aerosols in the atmosphere: Measurements at New Haven, Connecticut, and Las Cruces, New Mexico , 2007 .

[23]  J. Bottiger,et al.  An ink jet aerosol generator , 1998 .

[24]  M. Ammor Recent Advances in the Use of Intrinsic Fluorescence for Bacterial Identification and Characterization , 2007, Journal of Fluorescence.

[25]  Mikael Lindgren,et al.  Development of a fluorescence-based point detector for biological sensing , 2004, SPIE Security + Defence.

[26]  J. Saarela,et al.  Instrumentation for measuring fluorescence cross sections from airborne microsized particles. , 2008, Applied optics.

[27]  Alan C Samuels,et al.  Laser-induced breakdown spectroscopy of bacterial spores, molds, pollens, and protein: initial studies of discrimination potential. , 2003, Applied optics.

[28]  Determination of Fluorescence Cross‐Sections of Biological Aerosols , 2002 .

[29]  L. Reinisch,et al.  Fluorescence quantum efficiency of dry Bacillus globigii spores. , 2005, Optics express.

[30]  J. Ho,et al.  Estimation of Viable Spores in Bacillus atrophaeus (BG) Particles of 1 to 9 μm Size Range , 2008 .

[31]  L. Reinisch,et al.  Changes in the luminescence between dried and wet bacillus spores. , 2004, Applied optics.

[32]  B. Lighthart,et al.  Viable bacterial aerosol particle size distributions in the midsummer atmosphere at an isolated location in the high desert chaparral , 1995 .

[33]  Zoran Ristovski,et al.  Performance evaluation of the UVAPS: influence of physiological age of airborne bacteria and bacterial stress , 2003 .