Image reconstruction algorithm based on the extended regularised total least squares method for electrical capacitance tomography

Electrical capacitance tomography (ECT) is a non-invasive imaging technology that aims at the visualisation of the cross-sectional permittivity distribution of a dielectric object based on the measured capacitance data. Successful applications of ECT depend greatly on the precision and speed of the image reconstruction algorithms. ECT image reconstruction is a typical ill-posed problem, and its solution is unstable, that is, the solution is sensitive to noises in the input data. Methods that ensure the stability of a solution while enhancing the quality of the reconstructed images should be used to obtain a meaningful reconstruction result. An image reconstruction algorithm based on the regularised total least squares (TLS) method that considers the errors in both the sensitivity field matrix and the capacitance data for ECT is presented. The regularised TLS method is extended using a combination robust estimation technique and an extended stabilising functional according to the ill-posed characteristics of ECT, which transforms the image reconstruction problem into an optimisation problem. In addition, the Newton algorithm is employed to solve the objective functional. Numerical simulations indicate that the algorithm is feasible and overcomes the numerical instability of ECT image reconstruction; for the cases of the reconstructed objects considered here, the spatial resolution of the reconstructed images obtained using the algorithm is enhanced; as a result, an efficient method for ECT image reconstruction is introduced.

[1]  Roland Martin,et al.  Reconstruction of permittivity images from capacitance tomography data by using very fast simulated annealing , 2004 .

[2]  Masahiro Takei,et al.  Application of the generalized vector sampled pattern matching method to reconstruction of electrical capacitance CT images , 2004 .

[3]  C. Vogel,et al.  Analysis of bounded variation penalty methods for ill-posed problems , 1994 .

[4]  Peter J. Huber,et al.  Robust Statistics , 2005, Wiley Series in Probability and Statistics.

[5]  Wuqiang Yang,et al.  Electrical capacitance tomography for gas–solids flow measurement for circulating fluidized beds , 2005 .

[6]  Tomasz Dyakowski,et al.  Application of electrical capacitance tomography for measurement of gas-solids flow characteristics in a pneumatic conveying system , 2001 .

[7]  Wuqiang Yang,et al.  An image-reconstruction algorithm based on Landweber's iteration method for electrical-capacitance tomography , 1999 .

[8]  Weifu Fang,et al.  A nonlinear image reconstruction algorithm for electrical capacitance tomography , 2004 .

[9]  Lihui Peng,et al.  Image reconstruction algorithms for electrical capacitance tomography , 2003 .

[10]  Mark A. Bennett,et al.  The investigation of bubble column and foam processes using electrical capacitance tomography , 2002 .

[11]  Sabine Van Huffel,et al.  Overview of total least-squares methods , 2007, Signal Process..

[12]  Maurizio Cirrincione,et al.  Robust total least squares by the nonlinear MCA EXIN neuron , 1998, Proceedings. IEEE International Joint Symposia on Intelligence and Systems (Cat. No.98EX174).

[13]  T. Hebert,et al.  A generalized EM algorithm for 3-D Bayesian reconstruction from Poisson data using Gibbs priors. , 1989, IEEE transactions on medical imaging.

[14]  Yewang Su,et al.  Investigation of square fluidized beds using capacitance tomography: preliminary results , 2001 .

[15]  F. Garcia-Nocetti,et al.  Visualisation of gas–oil two-phase flows in pressurised pipes using electrical capacitance tomography , 2005 .

[16]  Michael T. Heath,et al.  Scientific Computing: An Introductory Survey , 1996 .

[17]  Zhang Cao,et al.  An image reconstruction algorithm based on total variation with adaptive mesh refinement for ECT , 2007 .

[18]  Pierre Gajan,et al.  Influence of the presence of an upstream annular liquid film on the wet gas flow measured by a Venturi in a downward vertical configuration , 2007 .

[19]  L. Landweber An iteration formula for Fredholm integral equations of the first kind , 1951 .

[20]  Roland Martin,et al.  Inversion of electrical capacitance tomography data by simulated annealing: Application to real two-phase gas-oil flow imaging , 2005 .

[21]  Lihui Peng,et al.  Using Regularization Methods for Image Reconstruction of Electrical Capacitance Tomography , 2000 .

[22]  Amir Beck,et al.  On the Solution of the Tikhonov Regularization of the Total Least Squares Problem , 2006, SIAM J. Optim..

[23]  Werner A. Stahel,et al.  Robust Statistics: The Approach Based on Influence Functions , 1987 .

[24]  Lihui Peng,et al.  Image reconstruction using a genetic algorithm for electrical capacitance tomography , 2005 .

[25]  Supachai Bangliang,et al.  The use of simultaneous iterative reconstruction technique for electrical capacitance tomography , 2000 .

[26]  Manuchehr Soleimani,et al.  Numerical modelling errors in electrical impedance tomography , 2007, Physiological measurement.

[27]  Todd Pugsley,et al.  Application of electrical capacitance tomography to the fluidized bed drying of pharmaceutical granule , 2005 .

[28]  Stephen J. Wright,et al.  Numerical Optimization , 2018, Fundamental Statistical Inference.

[29]  Yassir Makkawi,et al.  Electrical capacitance tomography for conventional fluidized bed measurements - remarks on the measuring technique , 2004 .

[30]  Manuchehr Soleimani,et al.  Nonlinear image reconstruction for electrical capacitance tomography using experimental data , 2005 .

[31]  Wuqiang Yang,et al.  Role of tomography in gas/solids flow measurement , 2000 .

[32]  Kwang Youn Kim,et al.  Modified iterative Landweber method in electrical capacitance tomography , 2006 .

[33]  Q. Marashdeh,et al.  Nonlinear forward problem solution for electrical capacitance tomography using feed-forward neural network , 2006, IEEE Sensors Journal.

[34]  F. Teixeira,et al.  A nonlinear image reconstruction technique for ECT using a combined neural network approach , 2006 .

[35]  Wuqiang Yang,et al.  Optimization of an iterative image reconstruction algorithm for electrical capacitance tomography , 1999 .

[36]  Sankaran Sundaresan,et al.  Electrical capacitance tomography measurements on vertical and inclined pneumatic conveying of granular solids , 2003 .

[37]  Brian S. Hoyle,et al.  Electrical capacitance tomography for flow imaging: system model for development of image reconstruction algorithms and design of primary sensors , 1992 .