Performance of a clinical gridded electron gun in magnetic fields: Implications for MRI-linac therapy.

PURPOSE MRI-linac therapy is a rapidly growing field, and requires that conventional linear accelerators are operated with the fringe field of MRI magnets. One of the most sensitive accelerator components is the electron gun, which serves as the source of the beam. The purpose of this work was to develop a validated finite element model (FEM) model of a clinical triode (or gridded) electron gun, based on accurate geometric and electrical measurements, and to characterize the performance of this gun in magnetic fields. METHODS The geometry of a Varian electron gun was measured using 3D laser scanning and digital calipers. The electric potentials and emission current of these guns were measured directly from six dose matched true beam linacs for the 6X, 10X, and 15X modes of operation. Based on these measurements, a finite element model (FEM) of the gun was developed using the commercial software opera/scala. The performance of the FEM model in magnetic fields was characterized using parallel fields ranging from 0 to 200 G in the in-line direction, and 0-35 G in the perpendicular direction. RESULTS The FEM model matched the average measured emission current to within 5% across all three modes of operation. Different high voltage settings are used for the different modes; the 6X, 10X, and 15X modes have an average high voltage setting of 15, 10, and 11 kV. Due to these differences, different operating modes show different sensitivities in magnetic fields. For in line fields, the first current loss occurs at 40, 20, and 30 G for each mode. This is a much greater sensitivity than has previously been observed. For perpendicular fields, first beam loss occurred at 8, 5, and 5 G and total beam loss at 27, 22, and 20 G. CONCLUSIONS A validated FEM model of a clinical triode electron gun has been developed based on accurate geometric and electrical measurements. Three different operating modes were simulated, with a maximum mean error of 5%. This gun shows greater sensitivity to in-line magnetic fields than previously presented models, and different operating modes show different sensitivity.

[1]  J. Yater,et al.  Secondary electron emission studies , 1997 .

[2]  Rob H N Tijssen,et al.  MRI-based tumor motion characterization and gating schemes for radiation therapy of pancreatic cancer. , 2014, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[3]  B G Fallone,et al.  Magnetic shielding investigation for a 6 MV in-line linac within the parallel configuration of a linac-MR system. , 2012, Medical physics.

[4]  J G M Kok,et al.  Towards MRI-guided linear accelerator control: gating on an MRI accelerator , 2011, Physics in medicine and biology.

[5]  P. Keall,et al.  A novel electron gun for inline MRI-linac configurations. , 2014, Medical physics.

[6]  B G Fallone,et al.  Effect of longitudinal magnetic fields on a simulated in-line 6 MV linac. , 2010, Medical physics.

[7]  B G Fallone,et al.  Effect of transverse magnetic fields on a simulated in-line 6 MV linac , 2010, Physics in medicine and biology.

[8]  Jan J W Lagendijk,et al.  The magnetic resonance imaging-linac system. , 2014, Seminars in radiation oncology.

[9]  B. Fallone,et al.  An integrated 6 MV linear accelerator model from electron gun to dose in a water tank. , 2010, Medical physics.

[10]  Rebecca Fahrig,et al.  A novel electron accelerator for MRI-Linac radiotherapy. , 2016, Medical physics.

[11]  Rebecca Fahrig,et al.  A study of the effect of in-line and perpendicular magnetic fields on beam characteristics of electron guns in medical linear accelerators. , 2011, Medical physics.

[12]  Masahiro Hiraoka,et al.  Development of an ultrasmall C-band linear accelerator guide for a four-dimensional image-guided radiotherapy system with a gimbaled x-ray head. , 2007, Medical physics.

[13]  B G Fallone,et al.  FEM design and simulation of a short, 10 MV, S-band Linac with Monte Carlo dose simulations. , 2015, Medical physics.

[14]  Claus Belka,et al.  Characteristics of gated treatment using an optical surface imaging and gating system on an Elekta linac , 2015, Radiation oncology.

[15]  Stuart Crozier,et al.  The Australian magnetic resonance imaging-linac program. , 2014, Seminars in radiation oncology.

[16]  Philip M. Evans,et al.  Gating characteristics of an Elekta radiotherapy treatment unit measured with three types of detector. , 2010, Physics in medicine and biology.

[17]  B. Fallone,et al.  The rotating biplanar linac-magnetic resonance imaging system. , 2014, Seminars in radiation oncology.

[18]  B. Fallone,et al.  Feasibility of producing a short, high energy s-band linear accelerator using a klystron power source. , 2013, Medical physics.