Preclinical evaluation of an integrated robotic system for magnetic resonance imaging guided shoulder arthrography

Abstract. Shoulder arthrography is a diagnostic procedure which involves injecting a contrast agent into the joint space for enhanced visualization of anatomical structures. Typically, a contrast agent is injected under fluoroscopy or computed tomography (CT) guidance, resulting in exposure to ionizing radiation, which should be avoided especially in pediatric patients. The patient then waits for the next available magnetic resonance imaging (MRI) slot for obtaining high-resolution anatomical images for diagnosis, which can result in long procedure times. Performing the contrast agent injection under MRI guidance could overcome both these issues. However, it comes with the challenges of the MRI environment including high magnetic field strength, limited ergonomic patient access, and lack of real-time needle guidance. We present the development of an integrated robotic system to perform shoulder arthrography procedures under intraoperative MRI guidance, eliminating fluoroscopy/CT guidance and patient transportation from the fluoroscopy/CT room to the MRI suite. The average accuracy of the robotic manipulator in benchtop experiments is 0.90 mm and 1.04 deg, whereas the average accuracy of the integrated system in MRI phantom experiments is 1.92 mm and 1.28 deg at the needle tip. Based on the American Society for Testing and Materials (ASTM) tests performed, the system is classified as MR conditional.

[1]  Kemal Tuncali,et al.  Design evaluation of a double ring RCM mechanism for robotic needle guidance in MRI-guided liver interventions , 2013, 2013 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[2]  Kevin Cleary,et al.  Shoulder-Mounted Robot for MRI-guided arthrography: Accuracy and mounting study , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[3]  Dan Stoianovici,et al.  MR Safe Robot, FDA Clearance, Safety and Feasibility of Prostate Biopsy Clinical Trial , 2017, IEEE/ASME Transactions on Mechatronics.

[4]  Nobuhiko Hata,et al.  System Integration and Preliminary Clinical Evaluation of a Robotic System for MRI-Guided Transperineal Prostate Biopsy , 2019, J. Medical Robotics Res..

[5]  Kevin Cleary,et al.  MRI Robots for Needle-Based Interventions: Systems and Technology , 2018, Annals of Biomedical Engineering.

[6]  Nikolai Hungr,et al.  Design and Validation of a CT- and MRI-Guided Robot for Percutaneous Needle Procedures , 2016, IEEE Transactions on Robotics.

[7]  Jacques Gangloff,et al.  A Patient-Mounted Robotic Platform for CT-Scan Guided Procedures , 2008, IEEE Transactions on Biomedical Engineering.

[8]  G. Fichtinger,et al.  Development and Evaluation of an Actuated MRI-Compatible Robotic System for MRI-Guided Prostate Intervention , 2013, IEEE/ASME Transactions on Mechatronics.

[9]  Kevin Cleary,et al.  A prototype body-mounted MRI-compatible robot for needle guidance in shoulder arthrography , 2014, 5th IEEE RAS/EMBS International Conference on Biomedical Robotics and Biomechatronics.

[10]  Gang Li,et al.  In‐bore prostate transperineal interventions with an MRI‐guided parallel manipulator: system development and preliminary evaluation , 2016, The international journal of medical robotics + computer assisted surgery : MRCAS.

[11]  Pedro Moreira,et al.  The MIRIAM Robot: A Novel Robotic System for MR-Guided Needle Insertion in the Prostate , 2017, J. Medical Robotics Res..

[12]  Conor J. Walsh,et al.  A Patient-Mounted, Telerobotic Tool for CT-Guided Percutaneous , 2008 .

[13]  Nobuhiko Hata,et al.  Piezoelectrically Actuated Robotic System for MRI-Guided Prostate Percutaneous Therapy , 2015, IEEE/ASME Transactions on Mechatronics.

[14]  Toru Shimizu,et al.  [Explanation of JIS T 62570 Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment]. , 2018, Nihon Hoshasen Gijutsu Gakkai zasshi.

[15]  Berk Gonenc,et al.  MRI-guided needle steering for targets in motion based on Fiber Bragg Grating sensors , 2016, 2016 IEEE SENSORS.

[16]  Essa Yacoub,et al.  Design of an MRI-compatible robotic stereotactic device for minimally invasive interventions in the breast. , 2004, Journal of biomechanical engineering.

[17]  Milan Sonka,et al.  3D Slicer as an image computing platform for the Quantitative Imaging Network. , 2012, Magnetic resonance imaging.

[18]  Bo Yang,et al.  Design, development, and evaluation of a master–slave surgical system for breast biopsy under continuous MRI , 2014, Int. J. Robotics Res..

[19]  Garnette R. Sutherland,et al.  NeuroArm: an MR compatible robot for microsurgery , 2003, CARS.

[20]  Roelf J. Wieringa Case study research in information systems engineering: how to generalize, how not to generalize, and how not to generalize too much , 2013, CAISE 2013.

[21]  Mehran Anvari,et al.  An image‐guided automated robot for MRI breast biopsy , 2016, The international journal of medical robotics + computer assisted surgery : MRCAS.

[22]  Kemal Tuncali,et al.  Configurable Automatic Detection and Registration of Fiducial Frames for Device-to-Image Registration in MRI-Guided Prostate Interventions , 2013, MICCAI.

[23]  H Iseki,et al.  Development of an MRI-compatible needle insertion manipulator for stereotactic neurosurgery. , 1995, Journal of image guided surgery.

[24]  Faye Y. Wu,et al.  An MRI Coil-Mounted Multi-Probe Robotic Positioner for Cryoablation , 2013 .

[25]  Gang Li,et al.  Closed-loop asymmetric-tip needle steering under continuous intraoperative MRI guidance , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[26]  Hao Su,et al.  Robotic System for MRI-Guided Stereotactic Neurosurgery , 2015, IEEE Transactions on Biomedical Engineering.

[27]  Jaydev P. Desai,et al.  Toward the Development of a Flexible Mesoscale MRI-Compatible Neurosurgical Continuum Robot , 2017, IEEE Transactions on Robotics.

[28]  Kevin Cleary,et al.  Robotic system for MRI-guided shoulder arthrography: Accuracy evaluation , 2018, 2018 International Symposium on Medical Robotics (ISMR).

[29]  Francisco José Madrid-Cuevas,et al.  Automatic generation and detection of highly reliable fiducial markers under occlusion , 2014, Pattern Recognit..

[30]  Gabor Fichtinger,et al.  OpenIGTLink: an open network protocol for image‐guided therapy environment , 2009, The international journal of medical robotics + computer assisted surgery : MRCAS.

[31]  P. Cinquin,et al.  Light Puncture Robot for CT and MRI Interventions , 2008, IEEE Engineering in Medicine and Biology Magazine.