Mass flowrate characteristics of supercritical CO2 flowing through an electronic expansion valve

Abstract Electronic expansion valves (EEV) are employed increasingly in transcritical CO 2 systems. In order to investigate the mass flowrate characteristics of supercritical CO 2 flowing through an EEV, the effects of EEV outlet pressure on the mass flowrate of CO 2 is studied under constant EEV inlet pressure and inlet temperature. The two-phase flow patterns of supercritical CO 2 flowing through an EEV are revealed, and the conventional choked flow judgment formulas is proved effective for supercritical CO 2 . Based on Bernoulli Equation with expansion factor, the mass flowrate correlation of supercritical CO 2 flowing through an EEV is presented. The influence of the expansion coefficient on the mass flowrate is considered in the correlation in which the correction coefficient is only affected by the EEV opening, the changing rate of the density and the pressure difference in the entrance region. The mass flowrate predicted by the correlation in this paper shows a good agreement with experimental data. The maximum relative errors are within 10%. The average and standard deviations are 0.76% and 5.9%, respectively.

[1]  Ramón Cabello,et al.  Experimental evaluation of the energy efficiency of a CO2 refrigerating plant working in transcritical conditions , 2008 .

[2]  Chen Jiangping,et al.  Experimental research on refrigerant mass flow coefficient of electronic expansion valve , 2005 .

[3]  Qifang Ye,et al.  A new model for depicting mass flow rate characteristic of electronic expansion valves , 2007 .

[4]  Jiangpin Chen,et al.  Choking phenomenon and pressure drop mechanism in electronic expansion valves , 2008 .

[5]  E. Torrella,et al.  Influence of the superheat associated to a semihermetic compressor of a transcritical CO2 refrigeration plant , 2010 .

[6]  Feng Cao,et al.  Experimental investigation on air-source transcritical CO2 heat pump water heater system at a fixed water inlet temperature , 2013 .

[7]  J. Pettersen,et al.  A new, efficient and environmentally benign system for car air-conditioning , 1993 .

[8]  Liu Jinghui,et al.  Experimental investigation on mass flow characteristics of electronic expansion valves with R22, R410A and R407C , 2009 .

[9]  Shi Lin,et al.  Refrigerant flow characteristics of electronic expansion valve based on thermodynamic analysis and experiment , 2008 .

[10]  Shanwei Ma,et al.  Experimental analysis of R22 and R407c flow through electronic expansion valve , 2006 .

[11]  Yong Chan Kim,et al.  Capacity modulation of an inverter-driven multi-air conditioner using electronic expansion valves , 2003 .

[12]  Qifang Ye,et al.  Experimental investigation of R407C and R410A flow through electronic expansion valve , 2007 .

[13]  Xiaolin Wang,et al.  Experimental investigation of the optimal heat rejection pressure for a transcritical CO2 heat pump water heater , 2013 .

[14]  Y. M. Niu,et al.  Experimentation and correlation of R744 two-phase flow through short tubes , 2004 .

[15]  Y. B. Tao,et al.  Experimental study on the performance of CO2 residential air-conditioning system with an internal heat exchanger , 2010 .

[16]  Silvia Minetto,et al.  CO2 heat pump for domestic hot water. , 2008 .

[17]  Honghyun Cho,et al.  Mass flow characteristics and empirical modeling of R22 and R410A flowing through electronic expansion valves , 2007 .

[18]  Wenhua Li,et al.  Simplified modeling analysis of mass flow characteristics in electronic expansion valve , 2013 .