Noise propagation in x-ray phase-contrast imaging and computed tomography

Three phase-retrieval algorithms, based on the transport-of-intensity equation and on the contrast transfer function for propagation-based imaging, and on the linearized geometrical optics approximation for analyser-based imaging, are investigated. The algorithms are compared in terms of their effect on propagation of noise from projection images to the corresponding phase-retrieved images and further to the computed tomography (CT) images/slices of a monomorphous object reconstructed using filtered backprojection algorithm. The comparison is carried out in terms of an integral noise characteristic, the variance, as well as in terms of a simple figure-of-merit, i.e. signal-to-noise ratio per unit dose. A gain factor is introduced that quantitatively characterizes the effect of phase retrieval on the variance of noise in the reconstructed projection images and in the axial slices of the object. Simple analytical expressions are derived for the gain factor and the signal-to-noise ratio, which indicate that the application of phase-retrieval algorithms can increase these parameters by up to two orders of magnitude compared to raw projection images and conventional CT, thus allowing significant improvement in the image quality and/or reduction of the x-ray dose delivered to the patient.

[1]  S. Wilkins,et al.  Linear algorithms for phase retrieval in the Fresnel region. 2. Partially coherent illumination , 2006 .

[2]  Cheng-Ying Chou,et al.  Influence of imaging geometry on noise texture in quantitative in-line X-ray phase-contrast imaging. , 2009, Optics express.

[3]  M F Kijewski,et al.  The noise power spectrum of CT images. , 1987, Physics in medicine and biology.

[4]  Paola Coan,et al.  X-ray phase-contrast imaging: from pre-clinical applications towards clinics , 2013, Physics in medicine and biology.

[5]  Timur E. Gureyev,et al.  Regimes of X-ray phase-contrast imaging with perfect crystals , 1997 .

[6]  S. I. Fedotov,et al.  Measurements of the parameters of shell targets for laser thermonuclear fusion using an x-ray schlieren method , 1979 .

[7]  J. S. Laughlin,et al.  Absorbed radiation dose in mammography. , 1979, Radiology.

[8]  Timur E. Gureyev,et al.  Accuracy and precision of reconstruction of complex refractive index in near-field single-distance propagation-based phase-contrast tomography , 2013 .

[9]  Wu Jin,et al.  Quantitative comparison of imaging performance of x-ray interferometric imaging and diffraction enhanced imaging. , 2008, Medical physics.

[10]  P. Cloetens,et al.  Quantitative comparison of direct phase retrieval algorithms in in-line phase tomography. , 2008, Medical physics.

[11]  P. C. Diemoz,et al.  Theoretical comparison of three X-ray phase-contrast imaging techniques: propagation-based imaging, analyzer-based imaging and grating interferometry. , 2012, Optics express.

[12]  A. Snigirev,et al.  On the possibilities of x-ray phase contrast microimaging by coherent high-energy synchrotron radiation , 1995 .

[13]  S. Wilkins,et al.  Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object , 2002, Journal of microscopy.

[14]  Jari Lindberg,et al.  Mathematical concepts of optical superresolution , 2012 .

[15]  Cheng-Ying Chou,et al.  Noise texture and signal detectability in propagation-based x-ray phase-contrast tomography. , 2010, Medical physics.

[16]  Graham R. Davis The effect of linear interpolation of the filtered projections on image noise in x-ray computed tomography , 1994 .

[17]  E. Förster,et al.  Double crystal diffractometry for the characterization of targets for laser fusion experiments , 1980 .

[18]  Paola Coan,et al.  Comparison of analyzer-based imaging computed tomography extraction algorithms and application to bone-cartilage imaging , 2010, Physics in medicine and biology.

[19]  D. C. Barber,et al.  Medical Imaging-The Assessment of Image Quality , 1996 .

[20]  A Bravin,et al.  Analytical and experimental determination of signal-to-noise ratio and figure of merit in three phase-contrast imaging techniques. , 2012, Optics express.

[21]  F. Natterer The Mathematics of Computerized Tomography , 1986 .

[22]  Harrison H. Barrett,et al.  Foundations of Image Science , 2003, J. Electronic Imaging.

[23]  T. Gureyev,et al.  Phase retrieval using coherent imaging systems with linear transfer functions , 2004 .

[24]  Norbert J. Pelc,et al.  The noise power spectrum in computed X-ray tomography. , 1978 .

[25]  M J Yaffe,et al.  Theoretical optimization of dual-energy x-ray imaging with application to mammography. , 1985, Medical physics.

[26]  M. Teague Deterministic phase retrieval: a Green’s function solution , 1983 .

[27]  K Faulkner,et al.  Noise and contrast detection in computed tomography images. , 1984, Physics in medicine and biology.

[28]  M. E. Alferieff,et al.  Refraction contrast in X-ray introscopy , 1991 .

[29]  S. Wilkins,et al.  Phase-contrast imaging using polychromatic hard X-rays , 1996, Nature.