Proximal Migration of Femoral Telescopic Rod in Children With Osteogenesis Imperfecta

Background: Intramedullary telescopic rod fixation has been used for stabilization of the long bones in growing children who have osteogenesis imperfecta. Proximal migration of the rod is the most common complication of telescopic rodding in the femur. The purposes of this study were to evaluate incidence and temporal pattern of proximal migration of the femoral rod, and to investigate factors related to it. Methods: A total of 50 patients with osteogenesis imperfecta, who had femur stabilized by telescopic rod with T-piece, were the subjects of this study. In patients having both the femora stabilized, only 1 femur was randomly selected for analysis. Hence, in 50 femora, migration-free survivorship was analyzed using the Kaplan-Meier method, and association with possible risk factors was analyzed by Cox regression analysis using the proportional hazards model. Factors investigated in the analysis include age at the time of surgery, sex, purpose of the index surgery, residual or developing angular deformity of the femur, rod position at the distal physis, persistent cortical gap at fracture/osteotomy site, Sillence classification, and type of telescopic rod. Results: Proximal migration was observed in 7 of 50 femora. Cumulative survival without proximal migration was 0.94 (95% CI, 0.87-1.01) in 1 year, and 0.85 (95% CI, 0.75-0.95) in 6 years. Factors significantly associated with proximal rod migration in Kaplan-Meier survivorship analysis and univariate Cox regression analysis were angular deformity, eccentric rod position at the distal physis, and persistent cortical gap. When these factors were analyzed by multivariate analysis, eccentric rod position at the distal physis was the only significant factor with a hazard ratio of 11.74. Conclusions: The risk of proximal rod migration can be reduced by complete correction of angular deformity and optimal placement of the rod at the distal physis. Our data also suggest that developing angular deformity or persistent osteotomy/fracture gap requires special attention at the possibility of proximal rod migration during follow-up. Level of Evidence: Level III, prognostic study.

[1]  M. Bell,et al.  Use of the Sheffield telescopic intramedullary rod system for the management of osteogenesis imperfecta: clinical outcomes at an average follow-up of nineteen years. , 2011, The Journal of bone and joint surgery. American volume.

[2]  K. Lee,et al.  Statistical consideration for bilateral cases in orthopaedic research. , 2010, The Journal of bone and joint surgery. American volume.

[3]  Dong Yeon Lee,et al.  Interlocking telescopic rod for patients with osteogenesis imperfecta. , 2007, The Journal of bone and joint surgery. American volume.

[4]  W. Enright,et al.  Bone plating in patients with type III osteogenesis imperfecta: results and complications. , 2006, The Iowa orthopaedic journal.

[5]  F. Glorieux,et al.  Delayed Osteotomy but Not Fracture Healing in Pediatric Osteogenesis Imperfecta Patients Receiving Pamidronate , 2004, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[6]  M. Bell,et al.  Surgical stabilisation of the lower limb in osteogenesis imperfecta using the Sheffield Telescopic Intramedullary Rod System. , 1998, The Journal of bone and joint surgery. British volume.

[7]  J. Jerosch,et al.  Complications after treatment of patients with osteogenesis imperfecta with a Bailey-Dubow rod , 1998, Archives of Orthopaedic and Trauma Surgery.

[8]  E. Ebramzadeh,et al.  Complications in the Use of the Bailey‐Dubow Extensible Nail , 1998, Clinical orthopaedics and related research.

[9]  P. Schoenecker,et al.  Management of lower-extremity deformities in osteogenesis imperfecta with extensible intramedullary rod technique: a 20-year experience. , 1998, Journal of pediatric orthopedics.

[10]  P. James,et al.  Telescoping Intramedullary Stabilization of the Lower Extremities for Severe Osteogenesis Imperfecta , 1990, Journal of pediatric orthopedics.

[11]  M. Bell,et al.  The role of expanding intramedullary rods in osteogenesis imperfecta. , 1989, The Journal of bone and joint surgery. British volume.

[12]  E. Bleck,et al.  Complications of Intramedullary Rods in Osteogenesis Imperfecta: Bailey‐Dubow Rods Versus Nonelongating Rods , 1988, Journal of pediatric orthopedics.

[13]  W. Sharrard,et al.  Intramedullary rodding with Bailey-Dubow extensible rods in osteogenesis imperfecta. An interim report of results and complications. , 1984, The Journal of bone and joint surgery. British volume.

[14]  R. Bailey Further clinical experience with the extensible nail. , 1981, Clinical orthopaedics and related research.

[15]  J. Albright Management overview of osteogenesis imperfecta. , 1981, Clinical orthopaedics and related research.

[16]  R. Bailey,et al.  Internal fixation of the femur in patients with osteogenesis imperfecta. , 1981, Clinical orthopaedics and related research.

[17]  D. Sillence,et al.  Genetic heterogeneity in osteogenesis imperfecta. , 1979, Journal of medical genetics.

[18]  R. Bailey,et al.  STUDIES OF LONGITUDINAL BONE GROWTH RESULTING IN AN EXTENSIBLE NAIL. , 1963, Surgical forum.

[19]  E. Millar,et al.  Fragmentation, Realignment, and Intramedullary Rod Fixation of Deformities of the Long Bones in Children: A Ten-year Appraisal , 1959 .

[20]  P. Esposito,et al.  Osteogenesis Imperfecta. , 1928, Proceedings of the Royal Society of Medicine.