Intracranial measurement of current densities induced by transcranial magnetic stimulation in the human brain

Transcranial magnetic stimulation (TMS) is a non-invasive technique that uses the principle of electromagnetic induction to generate currents in the brain via pulsed magnetic fields. The magnitude of such induced currents is unknown. In this study we measured the TMS induced current densities in a patient with implanted depth electrodes for epilepsy monitoring. A maximum current density of 12 microA/cm2 was recorded at a depth of 1 cm from scalp surface with the optimum stimulation orientation used in the experiment and an intensity of 7% of the maximal stimulator output. During TMS we recorded relative current variations under different stimulating coil orientations and at different points in the subject's brain. The results were in accordance with current theoretical models. The induced currents decayed with distance form the coil and varied with alterations in coil orientations. These results provide novel insight into the physical and neurophysiological processes of TMS.

[1]  J. H. Dripps,et al.  Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society , 1989 .

[2]  K. Foster,et al.  Dielectric properties of tissues and biological materials: a critical review. , 1989, Critical reviews in biomedical engineering.

[3]  W Paulus,et al.  Transcranial magnetic stimulation: its current role in epilepsy research , 1998, Epilepsy Research.

[4]  S. Ueno,et al.  Simulation of the influence of tissue inhomogeneity on nerve excitation elicited by magnetic stimulation , 1998, Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286).

[5]  Hong Wang,et al.  Neuronal responses by transcranial magnetic stimulation in cortex , 2000, 25th International Conference on Infrared and Millimeter Waves (Cat. No.00EX442).

[6]  M. Chilbert,et al.  Measurement of magnetically induced current density in saline in vivo , 1989, Images of the Twenty-First Century. Proceedings of the Annual International Engineering in Medicine and Biology Society,.

[7]  I. L. Freeston,et al.  Finite element modelling of magnetic stimulation of the spine , 1996, Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[8]  S. Bandinelli,et al.  Effects of coil design on delivery of focal magnetic stimulation. Technical considerations. , 1990, Electroencephalography and clinical neurophysiology.

[9]  E. Wassermann Risk and safety of repetitive transcranial magnetic stimulation: report and suggested guidelines from the International Workshop on the Safety of Repetitive Transcranial Magnetic Stimulation, June 5-7, 1996. , 1998, Electroencephalography and clinical neurophysiology.

[10]  M Hallett,et al.  The heating of metal electrodes during rapid-rate magnetic stimulation: a possible safety hazard. , 1992, Electroencephalography and clinical neurophysiology.

[11]  C. Elger,et al.  Safety of single and repetitive focal transcranial magnetic stimuli as assessed by intracranial EEG recordings in patients with partial epilepsy , 1999, Journal of Neurology.

[12]  M Hallett,et al.  A theoretical calculation of the electric field induced in the cortex during magnetic stimulation. , 1991, Electroencephalography and clinical neurophysiology.

[13]  P. Maccabee,et al.  Spatial distribution of the electric field induced in volume by round and figure '8' magnetic coils: relevance to activation of sensory nerve fibers. , 1990, Electroencephalography and clinical neurophysiology.

[14]  T. Yoshino,et al.  Estimation of focus of electric field in an inhomogeneous medium exposed by pulsed magnetic field , 1999, Proceedings of the First Joint BMES/EMBS Conference. 1999 IEEE Engineering in Medicine and Biology 21st Annual Conference and the 1999 Annual Fall Meeting of the Biomedical Engineering Society (Cat. N.

[15]  S. Ueno,et al.  Magnetic Stimulation of the Human Brain , 1992, Annals of the New York Academy of Sciences.

[16]  D. Cohen,et al.  Developing a more focal magnetic stimulator. Part II: Fabricating coils and measuring induced current distributions. , 1991, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[17]  H. Sackeim,et al.  333. Intracerebral measurement of rTMS and ECS induced voltage in vivo , 1998, Biological Psychiatry.

[18]  Kenneth R. Foster Biological Effects of Electromagnetic Fields , 1999 .

[19]  G Cerri,et al.  An accurate 3-D model for magnetic stimulation of the brain cortex. , 1995, Journal of medical engineering & technology.

[20]  Timothy A. Wagner,et al.  Field distributions within the human cortex induced by transcranial magnetic simulation , 2001 .

[21]  S Noachtar,et al.  Motor cortex excitability in patients with focal epilepsy , 2000, Epilepsy Research.

[22]  H. Sackeim,et al.  Sham TMS: intracerebral measurement of the induced electrical field and the induction of motor-evoked potentials , 2001, Biological Psychiatry.