Real-Time Knee Adduction Moment Feedback Training Using an Elliptical Trainer

The external knee adduction moment (EKAM) is associated with knee osteoarthritis (OA) in many aspects including presence, progression, and severity of knee OA. Despite of its importance, there is a lack of EKAM estimation methods that can provide patients with knee OA real-time EKAM biofeedback for training and clinical evaluations without using a motion analysis laboratory. A practical real-time EKAM estimation method, which utilizes kinematics measured by a simple six degree-of-freedom goniometer and kinetics measured by a multi-axis force sensor underneath the foot, was developed to provide real-time feedback of the EKAM to the patients during stepping on an elliptical trainer, which can potentially be used to control and alter the EKAM. High reliability (ICC(2,1): 0.9580) of the real-time EKAM estimation method was verified through stepping trials of seven subjects without musculoskeletal disorders. Combined with advantages of elliptical trainers including functional weight-bearing stepping and mitigation of impulsive forces, the real-time EKAM estimation method is expected to help patients with knee OA better control frontal plane knee loading and reduce knee OA development and progression.

[1]  J. Block,et al.  Relationship between pain and medial knee joint loading in mild radiographic knee osteoarthritis. , 2007, Arthritis and rheumatism.

[2]  T. Miyazaki,et al.  Dynamic load at baseline can predict radiographic disease progression in medial compartment knee osteoarthritis , 2002, Annals of the rheumatic diseases.

[3]  T. Andriacchi,et al.  A relationship between gait and clinical changes following high tibial osteotomy. , 1985, The Journal of bone and joint surgery. American volume.

[4]  Kevin J Deluzio,et al.  Robust features of knee osteoarthritis in joint moments are independent of reference frame selection. , 2011, Clinical biomechanics.

[5]  Yupeng Ren,et al.  Offaxis neuromuscular training of knee injuries using an offaxis robotic elliptical trainer , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[6]  D. Altman,et al.  Measuring agreement in method comparison studies , 1999, Statistical methods in medical research.

[7]  S. Gabriel,et al.  Estimates of the prevalence of arthritis and other rheumatic conditions in the United States. Part II. , 2008, Arthritis and rheumatism.

[8]  Richard M. Smith,et al.  The association of external knee adduction moment with biomechanical variables in osteoarthritis: a systematic review. , 2009, The Knee.

[9]  R. Wells The projection of the ground reaction force as a predictor of internal joint moments. , 1981, Bulletin of prosthetics research.

[10]  R Shiavi,et al.  Helical motion analysis of the knee--I. Methodology for studying kinematics during locomotion. , 1987, Journal of biomechanics.

[11]  E B Marsolais,et al.  The gait laboratory force plate at the Cleveland VA Medical Center. , 1980, Bulletin of prosthetics research.

[12]  F. Bowling,et al.  Conservative biomechanical strategies for knee osteoarthritis , 2011, Nature Reviews Rheumatology.

[13]  Mark R Cutkosky,et al.  Training multi-parameter gaits to reduce the knee adduction moment with data-driven models and haptic feedback. , 2011, Journal of biomechanics.

[14]  R. McCarney,et al.  Knee pain and osteoarthritis in older adults: a review of community burden and current use of primary health care , 2001, Annals of the rheumatic diseases.

[15]  Anthony G Schache,et al.  The effect of gait modification on the external knee adduction moment is reference frame dependent. , 2008, Clinical biomechanics.

[16]  S. Hoppenfeld,et al.  Physical examination of the spine and extremities , 1976 .

[17]  J. Barrios,et al.  Gait retraining to reduce the knee adduction moment through real-time visual feedback of dynamic knee alignment. , 2010, Journal of biomechanics.

[18]  A. Wolf,et al.  Six‐week gait retraining program reduces knee adduction moment, reduces pain, and improves function for individuals with medial compartment knee osteoarthritis , 2014, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[19]  Michael A Hunt,et al.  Predicting dynamic knee joint load with clinical measures in people with medial knee osteoarthritis. , 2011, The Knee.

[20]  P. Veltink,et al.  Ambulatory measurement of the knee adduction moment in patients with osteoarthritis of the knee. , 2013, Journal of biomechanics.

[21]  Jeffrey A. Reinbolt,et al.  Design of patient-specific gait modifications for knee osteoarthritis rehabilitation , 2007, IEEE Transactions on Biomedical Engineering.

[22]  Thomas P Andriacchi,et al.  Secondary motions of the knee during weight bearing and non‐weight bearing activities , 2004, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[23]  Atlanta,et al.  Estimates of the prevalence of arthritis and other rheumatic conditions in the United States. Part I. , 2008, Arthritis and rheumatism.

[24]  M. Hunt,et al.  Feasibility of a gait retraining strategy for reducing knee joint loading: increased trunk lean guided by real-time biofeedback. , 2011, Journal of biomechanics.

[25]  T. Andriacchi,et al.  Interaction between active and passive knee stabilizers during level walking , 1991, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[26]  T. Andriacchi,et al.  Gait modification via verbal instruction and an active feedback system to reduce peak knee adduction moment. , 2010, Journal of biomechanical engineering.

[27]  Tung-Wu Lu,et al.  Joint loading in the lower extremities during elliptical exercise. , 2007, Medicine and science in sports and exercise.

[28]  J. Fleiss,et al.  Intraclass correlations: uses in assessing rater reliability. , 1979, Psychological bulletin.

[29]  L. Zhang,et al.  Muscle strength in knee varus and valgus. , 2001, Medicine and science in sports and exercise.

[30]  Peter H. Veltink,et al.  Influence of the instrumented force shoe on gait pattern in patients with osteoarthritis of the knee , 2011, Medical & Biological Engineering & Computing.

[31]  L. Zhang,et al.  Dynamic and static control of the human knee joint in abduction-adduction. , 2001, Journal of biomechanics.

[32]  T. Andriacchi,et al.  Potential strategies to reduce medial compartment loading in patients with knee osteoarthritis of varying severity: reduced walking speed. , 2004, Arthritis and rheumatism.

[33]  T P Andriacchi,et al.  Hip motion and moments during gait relate directly to proximal femoral bone mineral density in patients with hip osteoarthritis. , 1998, Journal of biomechanics.

[34]  Debra E Hurwitz,et al.  Normalization of joint moments during gait: a comparison of two techniques. , 2003, Journal of biomechanics.

[35]  M. Pierrynowski Biomechanics of overground vs. treadmill walking in healthy individuals , 2009 .

[36]  V. M. Zat︠s︡iorskiĭ Kinetics of human motion , 2002 .

[37]  E S Grood,et al.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. , 1983, Journal of biomechanical engineering.

[38]  Hyung-Soon Park,et al.  Comparison of elliptical training, stationary cycling, treadmill walking and overground walking. , 2011, Gait & posture.

[39]  T. Andriacchi,et al.  Knee adduction moment, serum hyaluronan level, and disease severity in medial tibiofemoral osteoarthritis. , 1998, Arthritis and rheumatism.

[40]  Hyung-Soon Park,et al.  A Pivoting Elliptical Training System for Improving Pivoting Neuromuscular Control and Rehabilitating Musculoskeletal Injuries , 2013, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[41]  K. Yasuda,et al.  The mechanics of treatment of the osteoarthritic knee with a wedged insole. , 1987, Clinical orthopaedics and related research.

[42]  Li-Qun Zhang,et al.  Six degrees-of-freedom kinematics of ACL deficient knees during locomotion-compensatory mechanism. , 2003, Gait & posture.

[43]  T. Besier,et al.  Real-time knee adduction moment feedback for gait retraining through visual and tactile displays. , 2011, Journal of biomechanical engineering.

[44]  J. Favre,et al.  A neural network model to predict knee adduction moment during walking based on ground reaction force and anthropometric measurements. , 2012, Journal of biomechanics.

[45]  Michael A Hunt,et al.  Gait modification strategies for altering medial knee joint load: A systematic review , 2011, Arthritis care & research.

[46]  Daniel Vélez Día,et al.  Biomechanics and Motor Control of Human Movement , 2013 .

[47]  Improvement in off-axis neuromuscular control through pivoting elliptical training: Implication for knee injury prevention , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[48]  Huosheng Hu,et al.  Human motion tracking for rehabilitation - A survey , 2008, Biomed. Signal Process. Control..

[49]  Benjamin J. Fregly,et al.  Gait Modification to Treat Knee Osteoarthritis , 2012, HSS Journal.

[50]  Thad W. Buster,et al.  Similarity of Joint Kinematics and Muscle Demands Between Elliptical Training and Walking: Implications for Practice , 2010, Physical Therapy.

[51]  J. Riskowski,et al.  Gait and neuromuscular adaptations after using a feedback-based gait monitoring knee brace. , 2010, Gait & posture.

[52]  A. Mündermann,et al.  Implications of increased medio-lateral trunk sway for ambulatory mechanics. , 2008, Journal of biomechanics.

[53]  M. Cutkosky,et al.  Toe-in gait reduces the first peak knee adduction moment in patients with medial compartment knee osteoarthritis. , 2013, Journal of biomechanics.

[54]  Wells Rp The projection of the ground reaction force as a predictor of internal joint moments. , 1981 .

[55]  Hartmut Witte,et al.  ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion--part I: ankle, hip, and spine. International Society of Biomechanics. , 2002, Journal of biomechanics.