Sensitivity enhancement of (Hyper-)CEST image series by exploiting redundancies in the spectral domain.
暂无分享,去创建一个
Christopher Witte | Leif Schröder | M. Kunth | L. Schröder | Jörg Döpfert | C. Witte | Martin Kunth | J. Döpfert | Christopher Witte
[1] L. Schröder,et al. NMR of hyperpolarised probes , 2013, NMR in biomedicine.
[2] R E Lenkinski,et al. Keyhole chemical exchange saturation transfer , 2012, Magnetic resonance in medicine.
[3] M. Kunth,et al. Hyperpolarized xenon for NMR and MRI applications. , 2012, Journal of visualized experiments : JoVE.
[4] M. Kunth,et al. Optimized use of reversible binding for fast and selective NMR localization of caged xenon. , 2012, Angewandte Chemie.
[5] M. Kunth,et al. Inside Back Cover: Optimized Use of Reversible Binding for Fast and Selective NMR Localization of Caged XenonZ202481 (Angew. Chem. Int. Ed. 33/2012) , 2012 .
[6] J. Dutasta,et al. A sensitive zinc-activated 129Xe MRI probe. , 2012, Angewandte Chemie.
[7] P. Bachert,et al. Analytical solution for the depolarization of hyperpolarized nuclei by chemical exchange saturation transfer between free and encapsulated xenon (HyperCEST). , 2012, The Journal of chemical physics.
[8] J. Dutasta,et al. Cell uptake of a biosensor detected by hyperpolarized 129Xe NMR: the transferrin case. , 2011, Bioorganic & medicinal chemistry.
[9] Nirbhay N. Yadav,et al. Chemical exchange saturation transfer (CEST): What is in a name and what isn't? , 2011, Magnetic resonance in medicine.
[10] Nadjia Kachenoura,et al. Signal-to-noise ratio improvement in dynamic contrast-enhanced CT and MR imaging with automated principal component analysis filtering. , 2011, Radiology.
[11] S. Lingala,et al. Accelerated Dynamic MRI Exploiting Sparsity and Low-Rank Structure: k-t SLR , 2011, IEEE Transactions on Medical Imaging.
[12] A. Pines,et al. MRI thermometry based on encapsulated hyperpolarized xenon. , 2010, Chemphyschem : a European journal of chemical physics and physical chemistry.
[13] L. Allen,et al. Extracting physically interpretable data from electron energy-loss spectra. , 2010, Ultramicroscopy.
[14] A. Pines,et al. Xenon-based molecular sensors in lipid suspensions. , 2010, Journal of magnetic resonance.
[15] E. Terreno,et al. Methods for an improved detection of the MRI-CEST effect. , 2009, Contrast media & molecular imaging.
[16] Kay Nehrke,et al. k‐t PCA: Temporally constrained k‐t BLAST reconstruction using principal component analysis , 2009, Magnetic resonance in medicine.
[17] Emmanuel J. Candès,et al. Matrix Completion With Noise , 2009, Proceedings of the IEEE.
[18] Mark A Griswold,et al. PARACEST MRI with improved temporal resolution , 2009, Magnetic resonance in medicine.
[19] Emmanuel J. Candès,et al. A Singular Value Thresholding Algorithm for Matrix Completion , 2008, SIAM J. Optim..
[20] Shoujun Xu,et al. Novel detection schemes of nuclear magnetic resonance and magnetic resonance imaging: applications from analytical chemistry to molecular sensors. , 2008, Annual review of analytical chemistry.
[21] Emmanuel J. Candès,et al. Exact Matrix Completion via Convex Optimization , 2008, Found. Comput. Math..
[22] A. Pines,et al. Temperature-controlled molecular depolarization gates in nuclear magnetic resonance. , 2008, Angewandte Chemie.
[23] Leif Schröder,et al. Temperature response of 129Xe depolarization transfer and its application for ultrasensitive NMR detection. , 2008, Physical review letters.
[24] D. Donoho,et al. Sparse MRI: The application of compressed sensing for rapid MR imaging , 2007, Magnetic resonance in medicine.
[25] K. T. Block,et al. Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint , 2007, Magnetic resonance in medicine.
[26] Christian Hilty,et al. Molecular Imaging Using a Targeted Magnetic Resonance Hyperpolarized Biosensor , 2006, Science.
[27] Dwight G Nishimura,et al. Single breath‐hold whole‐heart MRA using variable‐density spirals at 3t , 2006, Magnetic resonance in medicine.
[28] P. Gemperline. Principal Component Analysis , 2003, Encyclopedia of Machine Learning.
[29] B. M. Goodson,et al. Nuclear magnetic resonance of laser-polarized noble gases in molecules, materials, and organisms. , 2002, Journal of magnetic resonance.
[30] A G Webb,et al. Unifying linear prior‐information‐driven methods for accelerated image acquisition , 2001, Magnetic resonance in medicine.
[31] A. Pines,et al. Functionalized xenon as a biosensor , 2001, Proceedings of the National Academy of Sciences of the United States of America.
[32] R S Balaban,et al. A new class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST). , 2000, Journal of magnetic resonance.
[33] F. Jolesz,et al. Gradient-Echo Imaging Considerations for Hyperpolarized 129Xe MR , 1996, Journal of magnetic resonance. Series B.
[34] H. Gudbjartsson,et al. The rician distribution of noisy mri data , 1995, Magnetic resonance in medicine.
[35] L. Schröder. Xenon for NMR biosensing--inert but alert. , 2013, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.
[36] Hao Gao,et al. Compressed Sensing using Prior Rank , Intensity and Sparsity Model ( PRISM ) : Applications in Cardiac Cine MRI , 2011 .
[37] J. Dutasta,et al. Cryptophanes and their complexes--present and future. , 2009, Chemical reviews.
[38] Jeffrey S. Anderson,et al. Improving rank constrained reconstructions using prior information with reordering , 2022 .