Vitreous Image Enhancement in an Ophthalmic Sonographic Imaging System Using Golay Coded Excitation
暂无分享,去创建一个
Shangkai Gao | Qiyu Peng | Shangkai Gao | Kai Liu | Xueqiao Wang | Xueqiao Wang | Q. Peng | Kai Liu
[1] R. Y. Chiao. B‐mode blood flow (B‐Flow) imaging , 2001 .
[2] Jørgen Arendt Jensen,et al. Clinical use and evaluation of coded excitation in B-mode images , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).
[3] Nico de Jong,et al. Nonlinear coded excitation method for ultrasound contrast imaging. , 2003, Ultrasound in medicine & biology.
[4] Marcel J. E. Golay,et al. Complementary series , 1961, IRE Trans. Inf. Theory.
[5] M. Fox,et al. Practical spread spectrum pulse compression for ultrasonic tissue imaging , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[6] R. Y. Chiao,et al. Synthetic transmit aperture imaging using orthogonal Golay coded excitation , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).
[7] K. Boone,et al. Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study , 1996, Medical and Biological Engineering and Computing.
[8] J A Jensen,et al. Potential of coded excitation in medical ultrasound imaging. , 2000, Ultrasonics.
[9] P A Lewin,et al. Estimation of ultrasonic attenuation in a bone using coded excitation. , 2003, Ultrasonics.
[10] R. Y. Chiao,et al. Coded excitation for diagnostic ultrasound: a system developer's perspective , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[11] Tai-Kyong Song,et al. A low voltage portable system using modified Golay sequences , 2001, 2001 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.01CH37263).
[12] Tai-Kyong Song,et al. Multiple transmit focusing using modified orthogonal Golay codes for small scale systems , 2003, IEEE Symposium on Ultrasonics, 2003.
[13] D. Cosgrove,et al. Advances in ultrasound. , 2002, Clinical radiology.
[14] 챠오리챠드융,et al. Ultrasonic imaging system with beamforming using unipolar or bipolar coded excitation , 2000 .
[15] P.C. Pedersen,et al. Target velocity estimation with FM and PW echo ranging Doppler systems I. Signal analysis , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[16] J. Arendt. Paper presented at the 10th Nordic-Baltic Conference on Biomedical Imaging: Field: A Program for Simulating Ultrasound Systems , 1996 .
[17] M. O'Donnell,et al. Coded excitation system for improving the penetration of real-time phased-array imaging systems , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[18] V. Newhouse,et al. Ultrasonic random‐signal flow measurement system , 1974 .
[19] P.C. Pedersen,et al. Target velocity estimation with FM and PW echo ranging Doppler systems. II. Systems analysis , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.