Can EEG and MEG detect signals from the human cerebellum?

The cerebellum plays a key role in the regulation of motor learning, coordination and timing, and has been implicated in sensory and cognitive processes as well. However, our current knowledge of its electrophysiological mechanisms comes primarily from direct recordings in animals, as investigations into cerebellar function in humans have instead predominantly relied on lesion, haemodynamic and metabolic imaging studies. While the latter provide fundamental insights into the contribution of the cerebellum to various cerebellar-cortical pathways mediating behaviour, they remain limited in terms of temporal and spectral resolution. In principle, this shortcoming could be overcome by monitoring the cerebellum’s electrophysiological signals. Non-invasive assessment of cerebellar electrophysiology in humans, however, is hampered by the limited spatial resolution of electroencephalography (EEG) and magnetoencephalography (MEG) in subcortical structures, i.e., deep sources. Furthermore, it has been argued that the anatomical configuration of the cerebellum leads to signal cancellation in MEG and EEG. Yet, claims that MEG and EEG are unable to detect cerebellar activity have been challenged by an increasing number of studies over the last decade. Here we address this controversy and survey reports in which electrophysiological signals were successfully recorded from the human cerebellum. We argue that the detection of cerebellum activity non-invasively with MEG and EEG is indeed possible and can be enhanced with appropriate methods, in particular using connectivity analysis in source space. We provide illustrative examples of cerebellar activity detected with MEG and EEG. Furthermore, we propose practical guidelines to optimize the detection of cerebellar activity with MEG and EEG. Finally, we discuss MEG and EEG signal contamination that may lead to localizing spurious sources in the cerebellum and suggest ways of handling such artefacts. This review is to be read as a perspective review that highlights that it is indeed possible to measure cerebellum with MEG and EEG and encourages MEG and EEG researchers to do so. Its added value beyond highlighting and encouraging is that it offers useful advice for researchers aspiring to investigate the cerebellum with MEG and EEG.

[1]  Mathieu Bourguignon,et al.  Coupling between human brain activity and body movements: Insights from non-invasive electromagnetic recordings , 2019, NeuroImage.

[2]  M. Butz,et al.  Synchronized brain network associated with essential tremor as revealed by magnetoencephalography , 2009, Movement disorders : official journal of the Movement Disorder Society.

[3]  Professor Dr. John C. Eccles,et al.  The Cerebellum as a Neuronal Machine , 1967, Springer Berlin Heidelberg.

[4]  C. Koch,et al.  The origin of extracellular fields and currents — EEG, ECoG, LFP and spikes , 2012, Nature Reviews Neuroscience.

[5]  Gareth R. Barnes,et al.  The use of anatomical constraints with MEG beamformers , 2003, NeuroImage.

[6]  M. V. D. Heuvel,et al.  Exploring the brain network: A review on resting-state fMRI functional connectivity , 2010, European Neuropsychopharmacology.

[7]  J. Thiran,et al.  Tracking the source of cerebellar epilepsy: Hemifacial seizures associated with cerebellar cortical dysplasia , 2013, Epilepsy Research.

[8]  Efrain Torres,et al.  Cerebellar Source Localization using Event-Related Potentials in a Simple Motor Task , 2019, 2019 9th International IEEE/EMBS Conference on Neural Engineering (NER).

[9]  David Poeppel,et al.  Reconstructing spatio-temporal activities of neural sources using an MEG vector beamformer technique , 2001, IEEE Transactions on Biomedical Engineering.

[10]  Christoph Pfeiffer,et al.  Evaluation of realistic layouts for next generation on-scalp MEG: spatial information density maps , 2017, Scientific Reports.

[11]  R. Burkard Human Auditory Evoked Potentials , 2010 .

[12]  D L Jewett,et al.  Human Auditory Evoked Potentials: Possible Brain Stem Components Detected on the Scalp , 1970, Science.

[13]  Dimitrios Pantazis,et al.  Coherent neural representation of hand speed in humans revealed by MEG imaging , 2007, Proceedings of the National Academy of Sciences.

[14]  Martin Luessi,et al.  MNE software for processing MEG and EEG data , 2014, NeuroImage.

[15]  Emily Ruzich,et al.  Characterizing hippocampal dynamics with MEG: A systematic review and evidence‐based guidelines , 2018, Human brain mapping.

[16]  A. Schnitzler,et al.  The neural basis of intermittent motor control in humans , 2002, Proceedings of the National Academy of Sciences of the United States of America.

[17]  Angela R Laird,et al.  Cerebellum and auditory function: An ALE meta‐analysis of functional neuroimaging studies , 2005, Human brain mapping.

[18]  Susanne M. Jaeggi,et al.  Resting state cortico-cerebellar functional connectivity networks: a comparison of anatomical and self-organizing map approaches , 2012, Front. Neuroanat..

[19]  I. M. Irger,et al.  [Investigation on the electric activity of phylogenetically different segments of the cerebellum in man and animal]. , 1951, Fiziologicheskii zhurnal SSSR imeni I. M. Sechenova.

[20]  Darren Price,et al.  Investigating the electrophysiological basis of resting state networks using magnetoencephalography , 2011, Proceedings of the National Academy of Sciences.

[21]  Srikantan S. Nagarajan,et al.  High-Frequency Oscillations in Distributed Neural Networks Reveal the Dynamics of Human Decision Making , 2007, Frontiers in human neuroscience.

[22]  Srikantan S. Nagarajan,et al.  The neural basis of event-time introspection , 2011, Consciousness and Cognition.

[23]  V. Jousmäki,et al.  Magnetic source imaging during a visually guided task , 1996, Neuroreport.

[24]  Dag Winkler,et al.  A 7-channel high-Tc SQUID-based on-scalp MEG system , 2019, bioRxiv.

[25]  Vincenzo Perciavalle,et al.  Processing of Limb Kinematics in the Interpositus Nucleus , 2010, The Cerebellum.

[26]  Andreas A. Ioannides,et al.  Distinct cerebellar lobules process arousal, valence and their interaction in parallel following a temporal hierarchy , 2015, NeuroImage.

[27]  Mário João Fartaria,et al.  Surface-based characteristics of the cerebellar cortex visualized with ultra-high field MRI , 2018, NeuroImage.

[28]  Matthew J. Brookes,et al.  Optically pumped magnetometers: From quantum origins to multi-channel magnetoencephalography , 2019, NeuroImage.

[29]  Noam Peled,et al.  Cortical Signal Suppression (CSS) for Detection of Subcortical Activity Using MEG and EEG , 2018, Brain Topography.

[30]  R. Ilmoniemi,et al.  Interpreting magnetic fields of the brain: minimum norm estimates , 2006, Medical and Biological Engineering and Computing.

[31]  D. Jaeger,et al.  Responses to tactile stimulation in deep cerebellar nucleus neurons result from recurrent activation in multiple pathways. , 2008, Journal of neurophysiology.

[32]  Pavitra Krishnaswamy,et al.  Sparsity enables estimation of both subcortical and cortical activity from MEG and EEG , 2017, Proceedings of the National Academy of Sciences.

[33]  Lau M. Andersen,et al.  Somatosensory responses to nothing: An MEG study of expectations during omission of tactile stimulations , 2018, NeuroImage.

[34]  John G. W. Samuelsson,et al.  Detectability of cerebellar activity with magnetoencephalography and electroencephalography , 2020, Human brain mapping.

[35]  V. Jousmäki,et al.  Neuromagnetic Cerebellar Activity Entrains to the Kinematics of Executed Finger Movements , 2018, The Cerebellum.

[36]  Jens Haueisen,et al.  Comparison of three-shell and simplified volume conductor models in magnetoencephalography , 2014, NeuroImage.

[37]  Donald C. Rojas,et al.  An extended motor network generates beta and gamma oscillatory perturbations during development , 2010, Brain and Cognition.

[38]  J. Gross,et al.  Role of the Cerebellum in Adaptation to Delayed Action Effects , 2017, Current Biology.

[39]  M. Ptito,et al.  A thalamocortical pathway for fast rerouting of tactile information to occipital cortex in congenital blindness , 2019, Nature Communications.

[40]  H. Freund,et al.  The cerebral oscillatory network of parkinsonian resting tremor. , 2003, Brain : a journal of neurology.

[41]  Richard B. Ivry,et al.  Universal Transform or Multiple Functionality? Understanding the Contribution of the Human Cerebellum across Task Domains , 2019, Neuron.

[42]  R. Bowtell,et al.  Using optically-pumped magnetometers to measure magnetoencephalographic signals in the human cerebellum , 2018, bioRxiv.

[43]  Joachim Gross,et al.  Evidence for Anticipatory Motor Control within a Cerebello-Diencephalic-Parietal Network , 2008, Journal of Cognitive Neuroscience.

[44]  S. Muthukumaraswamy,et al.  An MEG investigation of the neural mechanisms subserving complex visuomotor coordination. , 2011, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[45]  Thomas R. Knösche,et al.  A guideline for head volume conductor modeling in EEG and MEG , 2014, NeuroImage.

[46]  Jörn Diedrichsen,et al.  Functional boundaries in the human cerebellum revealed by a multi-domain task battery , 2019, Nature Neuroscience.

[47]  A. R. Anwar,et al.  Dynamic Imaging of Coherent Sources Reveals Different Network Connectivity Underlying the Generation and Perpetuation of Epileptic Seizures , 2013, PloS one.

[48]  Jan-Mathijs Schoffelen,et al.  A Tutorial Review of Functional Connectivity Analysis Methods and Their Interpretational Pitfalls , 2016, Front. Syst. Neurosci..

[49]  T. R. Carter,et al.  A 20-channel magnetoencephalography system based on optically pumped magnetometers. , 2017, Physics in medicine and biology.

[50]  K.-R. Muller,et al.  Optimizing Spatial filters for Robust EEG Single-Trial Analysis , 2008, IEEE Signal Processing Magazine.

[51]  Sarang S. Dalal,et al.  Photogrammetry-Based Head Digitization for Rapid and Accurate Localization of EEG Electrodes and MEG Fiducial Markers Using a Single Digital SLR Camera , 2017, Front. Neurosci..

[52]  J. Pellet L'électrocérébellogramme vermien au cours des états de veille et de sommeil , 1967 .

[53]  J. Osborne,et al.  Fully integrated standalone zero field optically pumped magnetometer for biomagnetism , 2018, OPTO.

[54]  R M Leahy,et al.  A sensor-weighted overlapping-sphere head model and exhaustive head model comparison for MEG. , 1999, Physics in medicine and biology.

[55]  Magnetic field associated with neural activities in an isolated cerebellum , 1987, Brain Research.

[56]  Gabriel Curio,et al.  Cingulate and cerebellar beta oscillations are engaged in the acquisition of auditory‐motor sequences , 2017, Human brain mapping.

[57]  Nikolaus Weiskopf,et al.  Flexible head-casts for high spatial precision MEG , 2017, Journal of Neuroscience Methods.

[58]  C. Michel,et al.  Electromagnetic Inverse Solutions in Anatomically Constrained Spherical Head Models , 2004, Brain Topography.

[59]  Wietske van der Zwaag,et al.  Topographic Maps of Visual Space in the Human Cerebellum , 2019, Current Biology.

[60]  Nicolas Brunel,et al.  High-Frequency Organization and Synchrony of Activity in the Purkinje Cell Layer of the Cerebellum , 2008, Neuron.

[61]  Robert Oostenveld,et al.  Similarities and differences between on-scalp and conventional in-helmet magnetoencephalography recordings , 2017, PloS one.

[62]  Jeremy D. Schmahmann,et al.  Functional topography of the cerebellum for motor and cognitive tasks: An fMRI study , 2012, NeuroImage.

[63]  M. Elam,et al.  High-T-c superconducting quantum interference device recordings of spontaneous brain activity: Towards high-T-c magnetoencephalography , 2012 .

[64]  A. Schienle,et al.  Cerebellar and Hippocampal Activation During Eyeblink Conditioning Depends on the Experimental Paradigm: A MEG Study , 2003, Neural plasticity.

[65]  Gareth R. Barnes,et al.  Group imaging of task-related changes in cortical synchronisation using nonparametric permutation testing , 2003, NeuroImage.

[66]  M. Petieau,et al.  “Cerebellar contribution to visuo-attentional alpha rhythm: insights from weightlessness” , 2016, Scientific Reports.

[67]  J. Karhu,et al.  Anticipatory cerebellar responses during somatosensory omission in man , 2000, Human brain mapping.

[68]  G. Cheron,et al.  Beta‐gamma burst stimulations of the inferior olive induce high‐frequency oscillations in the deep cerebellar nuclei , 2018, The European journal of neuroscience.

[69]  R S Dow,et al.  The electrical activity of the cerebellum and its functional significance , 1938, The Journal of physiology.

[70]  O. Bertrand,et al.  Oscillatory activity of the human cerebellum: The intracranial electrocerebellogram revisited , 2013, Neuroscience & Biobehavioral Reviews.

[71]  Short-latency evoked magnetic fields from the human auditory brainstem. , 1990, Advances in neurology.

[72]  David Poeppel,et al.  Asymptotic SNR of scalar and vector minimum-variance beamformers for neuromagnetic source reconstruction , 2004, IEEE Transactions on Biomedical Engineering.

[73]  Dag Winkler,et al.  On-scalp MEG SQUIDs are sensitive to early somatosensory activity unseen by conventional MEG , 2019, NeuroImage.

[74]  Y. Attal,et al.  Assessment of Subcortical Source Localization Using Deep Brain Activity Imaging Model with Minimum Norm Operators: A MEG Study , 2013, PloS one.

[75]  Théodore Papadopoulo,et al.  OpenMEEG: opensource software for quasistatic bioelectromagnetics , 2010, Biomedical engineering online.

[76]  S. Uematsu,et al.  Electroencephalographic recordings from deep cerebellar structures in patients with uncontrolled epileptic seizures. , 1974, Electroencephalography and clinical neurophysiology.

[77]  D. Cheyne,et al.  Neuromagnetic cerebellar activation during seizures arising from the motor cortex , 2011, Epilepsy Research.

[78]  P. Strick,et al.  Cerebellum and nonmotor function. , 2009, Annual review of neuroscience.

[79]  J. Badier,et al.  Deep brain activities can be detected with magnetoencephalography , 2019, Nature Communications.

[80]  Matthew J. Brookes,et al.  A new generation of magnetoencephalography: Room temperature measurements using optically-pumped magnetometers , 2017, NeuroImage.

[81]  J. Wessberg,et al.  Organization of motor output in slow finger movements in man. , 1993, The Journal of physiology.

[82]  Riitta Hari,et al.  Primary motor cortex and cerebellum are coupled with the kinematics of observed hand movements , 2013, NeuroImage.

[83]  J. Kitching,et al.  High-bandwidth optical magnetometer , 2012 .

[84]  J Gross,et al.  REPRINTS , 1962, The Lancet.

[85]  Lauri Parkkonen,et al.  Optical Co-registration of MRI and On-scalp MEG , 2018, Scientific Reports.

[86]  G. Nolte The magnetic lead field theorem in the quasi-static approximation and its use for magnetoencephalography forward calculation in realistic volume conductors. , 2003, Physics in medicine and biology.

[87]  Jochen Kaiser,et al.  Transfer entropy in magnetoencephalographic data: quantifying information flow in cortical and cerebellar networks. , 2011, Progress in biophysics and molecular biology.

[88]  Matthew J. Brookes,et al.  Wearable neuroimaging: Combining and contrasting magnetoencephalography and electroencephalography , 2019, NeuroImage.

[89]  R. Ilmoniemi,et al.  Magnetoencephalography-theory, instrumentation, and applications to noninvasive studies of the working human brain , 1993 .

[90]  Christian Bellebaum,et al.  Cerebellar involvement in executive control , 2008, The Cerebellum.

[91]  H Bantli Multi-electrode analysis of field potentials in the turtle cerebellum: an electrophysiological method for monitoring continuous spatial parameters. , 1972, Brain research.

[92]  Tianzi Jiang,et al.  Resting-state functional connectivity of the vermal and hemispheric subregions of the cerebellum with both the cerebral cortical networks and subcortical structures , 2012, NeuroImage.

[93]  G. Buzsáki,et al.  Cerebellar neuronal activity correlates with spike and wave EEG patterns in the rat , 1993, Epilepsy Research.

[94]  J. Karhu,et al.  Somatosensory evoked magnetic fields arising from sources in the human cerebellum , 1997, Brain Research.

[95]  J. Schoffelen,et al.  Source connectivity analysis with MEG and EEG , 2009, Human brain mapping.

[96]  R. Buckner The Cerebellum and Cognitive Function: 25 Years of Insight from Anatomy and Neuroimaging , 2013, Neuron.

[97]  Krish D. Singh,et al.  Visual gamma oscillations: The effects of stimulus type, visual field coverage and stimulus motion on MEG and EEG recordings , 2013, NeuroImage.

[98]  Joachim Gross,et al.  The cerebral oscillatory network associated with auditorily paced finger movements , 2005, NeuroImage.

[99]  伊藤 正男 The cerebellum and neural control , 1984 .

[100]  Kensuke Sekihara,et al.  Muscle afferent inputs from the hand activate human cerebellum sequentially through parallel and climbing fiber systems , 2003, Clinical Neurophysiology.

[101]  Mary Lou Coad,et al.  Mapping the 40-Hz auditory steady-state response using current density reconstructions , 2005, Hearing Research.

[102]  M. Butz,et al.  Synchronized brain network underlying postural tremor in Wilson's disease , 2006, Movement disorders : official journal of the Movement Disorder Society.

[103]  Robert T. Knight,et al.  Five-dimensional neuroimaging: Localization of the time–frequency dynamics of cortical activity , 2008, NeuroImage.

[104]  Ellen Covey,et al.  Basic electrophysiological methods , 2015 .

[105]  R. F. Thompson,et al.  Cerebellum: essential involvement in the classically conditioned eyelid response. , 1984, Science.

[106]  Irger Im,et al.  Investigation on the electric activity of phylogenetically different segments of the cerebellum in man and animal , 1951 .

[107]  M. Hämäläinen,et al.  Realistic conductivity geometry model of the human head for interpretation of neuromagnetic data , 1989, IEEE Transactions on Biomedical Engineering.

[108]  E. Formisano,et al.  Phase coupling in a cerebro-cerebellar network at 8-13 Hz during reading. , 2007, Cerebral cortex.

[109]  Freek E. Hoebeek,et al.  Causes and Consequences of Oscillations in the Cerebellar Cortex , 2008, Neuron.

[110]  Xavier Tricoche,et al.  Influence of tissue conductivity anisotropy on EEG/MEG field and return current computation in a realistic head model: A simulation and visualization study using high-resolution finite element modeling , 2006, NeuroImage.

[111]  M. Thaut,et al.  Neural Basis of Rhythmic Timing Networks in the Human Brain , 2003, Annals of the New York Academy of Sciences.

[112]  Robert Oostenveld,et al.  Using a structured-light 3D scanner to improve EEG source modeling with more accurate electrode positions , 2019, Journal of Neuroscience Methods.

[113]  J. Colebatch,et al.  The human electrocerebellogram (ECeG) recorded non-invasively using scalp electrodes , 2018, Neuroscience Letters.

[114]  J. Mäkelä,et al.  Sources of auditory brainstem responses revisited: Contribution by magnetoencephalography , 2009, Human brain mapping.

[115]  Jens Haueisen,et al.  Changes in scalp potentials and spatial smoothing effects of inclusion of dura layer in human head models for EEG simulations , 2014, Front. Neuroeng..